犬起搏器导联相关血栓形成:一项多中心回顾性研究

IF 1.5 2区 农林科学 Q2 VETERINARY SCIENCES
C. McGrath MVB , A. Dixon DVM , C. Hirst BVetMed, MVetMed , E.F. Bode BVSc, PhD , T. DeFrancesco DVM , R. Fries DVM , S. Gordon DVM, DVSc , D. Hogan DVM , Y. Martinez Pereira LdaVet , E. Mederska DVM , S. Ostenkamp DVM , K.T. Sykes DVM , J. Vitt DVM , S. Wesselowski DVM, MS , J.R. Payne BVetMed, MVetMed, PhD
{"title":"犬起搏器导联相关血栓形成:一项多中心回顾性研究","authors":"C. McGrath MVB ,&nbsp;A. Dixon DVM ,&nbsp;C. Hirst BVetMed, MVetMed ,&nbsp;E.F. Bode BVSc, PhD ,&nbsp;T. DeFrancesco DVM ,&nbsp;R. Fries DVM ,&nbsp;S. Gordon DVM, DVSc ,&nbsp;D. Hogan DVM ,&nbsp;Y. Martinez Pereira LdaVet ,&nbsp;E. Mederska DVM ,&nbsp;S. Ostenkamp DVM ,&nbsp;K.T. Sykes DVM ,&nbsp;J. Vitt DVM ,&nbsp;S. Wesselowski DVM, MS ,&nbsp;J.R. Payne BVetMed, MVetMed, PhD","doi":"10.1016/j.jvc.2023.06.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p><span><span>Pacemaker implantation is the </span>treatment of choice for clinically relevant </span>bradyarrhythmias<span>. Pacemaker-lead-associated thrombosis (PLAT) occurs in 23.0–45.0% of people with permanent transvenous pacemakers. Serious thromboembolic complications<span> are reported in 0.6–3.5%. The incidence of PLAT in dogs is unknown.</span></span></p></div><div><h3>Animals, materials and methods</h3><p>multicenter retrospective study of seven centers with 606 client-owned dogs undergoing permanent pacemaker implantation between 2012 and 2019. 260 dogs with a transvenous pacemaker with echocardiographic follow-up, 268 dogs with a transvenous pacemaker without echocardiographic follow-up and 78 dogs with an epicardial pacemaker.</p></div><div><h3>Results</h3><p><span>10.4% (27/260) of dogs with transvenous pacemakers and echocardiographic follow-up had PLAT identified. The median time to diagnosis was 175 days (6–1853 days). Pacemaker-lead-associated thrombosis was an incidental finding in 15/27 (55.6%) dogs. Of dogs with a urine protein:creatinine ratio measured at pacemaker implantation, dogs with PLAT were more likely to have </span>proteinuria<span> at pacemaker implantation vs. dogs without PLAT (6/6 (100.0%) vs. 21/52 (40.4%), P=0.007). Urine protein:creatinine ratio was measured in 12/27 (44.4%) dogs at PLAT diagnosis, with proteinuria identified in 10/12 (83.3%) dogs. Anti-thrombotic drugs were used following the identification of PLAT in 22/27 (81.5%) dogs. The thrombus<span> resolved in 9/15 (60.0%) dogs in which follow-up echocardiography was performed. Dogs with PLAT had shorter survival times from implantation compared to those without PLAT (677 days [9–1988 days] vs. 1105 days [1–2661 days], P=0.003).</span></span></p></div><div><h3>Conclusions</h3><p>Pacemaker-lead-associated thrombosis is identified in 10.4% (27/260) of dogs following transvenous pacing, is associated with proteinuria, can cause significant morbidity, and is associated with reduced survival times.</p></div>","PeriodicalId":48788,"journal":{"name":"Journal of Veterinary Cardiology","volume":"49 ","pages":"Pages 9-28"},"PeriodicalIF":1.5000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Pacemaker-lead-associated thrombosis in dogs: a multicenter retrospective study\",\"authors\":\"C. McGrath MVB ,&nbsp;A. Dixon DVM ,&nbsp;C. Hirst BVetMed, MVetMed ,&nbsp;E.F. Bode BVSc, PhD ,&nbsp;T. DeFrancesco DVM ,&nbsp;R. Fries DVM ,&nbsp;S. Gordon DVM, DVSc ,&nbsp;D. Hogan DVM ,&nbsp;Y. Martinez Pereira LdaVet ,&nbsp;E. Mederska DVM ,&nbsp;S. Ostenkamp DVM ,&nbsp;K.T. Sykes DVM ,&nbsp;J. Vitt DVM ,&nbsp;S. Wesselowski DVM, MS ,&nbsp;J.R. Payne BVetMed, MVetMed, PhD\",\"doi\":\"10.1016/j.jvc.2023.06.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><p><span><span>Pacemaker implantation is the </span>treatment of choice for clinically relevant </span>bradyarrhythmias<span>. Pacemaker-lead-associated thrombosis (PLAT) occurs in 23.0–45.0% of people with permanent transvenous pacemakers. Serious thromboembolic complications<span> are reported in 0.6–3.5%. The incidence of PLAT in dogs is unknown.</span></span></p></div><div><h3>Animals, materials and methods</h3><p>multicenter retrospective study of seven centers with 606 client-owned dogs undergoing permanent pacemaker implantation between 2012 and 2019. 260 dogs with a transvenous pacemaker with echocardiographic follow-up, 268 dogs with a transvenous pacemaker without echocardiographic follow-up and 78 dogs with an epicardial pacemaker.</p></div><div><h3>Results</h3><p><span>10.4% (27/260) of dogs with transvenous pacemakers and echocardiographic follow-up had PLAT identified. The median time to diagnosis was 175 days (6–1853 days). Pacemaker-lead-associated thrombosis was an incidental finding in 15/27 (55.6%) dogs. Of dogs with a urine protein:creatinine ratio measured at pacemaker implantation, dogs with PLAT were more likely to have </span>proteinuria<span> at pacemaker implantation vs. dogs without PLAT (6/6 (100.0%) vs. 21/52 (40.4%), P=0.007). Urine protein:creatinine ratio was measured in 12/27 (44.4%) dogs at PLAT diagnosis, with proteinuria identified in 10/12 (83.3%) dogs. Anti-thrombotic drugs were used following the identification of PLAT in 22/27 (81.5%) dogs. The thrombus<span> resolved in 9/15 (60.0%) dogs in which follow-up echocardiography was performed. Dogs with PLAT had shorter survival times from implantation compared to those without PLAT (677 days [9–1988 days] vs. 1105 days [1–2661 days], P=0.003).</span></span></p></div><div><h3>Conclusions</h3><p>Pacemaker-lead-associated thrombosis is identified in 10.4% (27/260) of dogs following transvenous pacing, is associated with proteinuria, can cause significant morbidity, and is associated with reduced survival times.</p></div>\",\"PeriodicalId\":48788,\"journal\":{\"name\":\"Journal of Veterinary Cardiology\",\"volume\":\"49 \",\"pages\":\"Pages 9-28\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Veterinary Cardiology\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1760273423000541\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Veterinary Cardiology","FirstCategoryId":"97","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1760273423000541","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

引言起搏器植入是临床相关缓慢性心律失常的首选治疗方法。使用永久性经静脉起搏器的患者中,23.0–45.0%会出现起搏器铅相关血栓形成(PLAT)。据报道,严重的血栓栓塞并发症发生率为0.6-3.5%。PLAT在狗中的发生率尚不清楚。动物、材料和方法:2012年至2019年间,对7个中心的606只客户拥有的狗进行永久性起搏器植入的多中心回顾性研究。260只狗带经静脉起搏器并进行超声心动图随访,268只狗带未经超声心动图追踪的经静脉起搏器,78只狗带心外膜起搏器。结果使用经静脉起搏器和超声心动图随访的狗中,10.4%(27/260)的PLAT被识别。中位诊断时间为175天(6-1853天)。在15/27(55.6%)只狗中偶然发现起搏器铅相关血栓形成。在起搏器植入时测得尿蛋白与肌酐比值的狗中,患有PLAT的狗在起搏器植入后比没有PLAT的更容易出现蛋白尿(6/6(100.0%)vs.21/52(40.4%),P=0.007)。在PLAT诊断时,12/27(44.4%)只狗测得尿蛋白质与肌酐比值,10/12(83.3%)只狗发现蛋白尿。在对22/27(81.5%)只狗进行PLAT鉴定后,使用了抗血栓药物。随访超声心动图的9/15只(60.0%)犬血栓消退。与未植入PLAT的狗相比,植入PLAT后的狗存活时间更短(677天[9-1988天]与1105天[1-2661天],P=0.003)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Pacemaker-lead-associated thrombosis in dogs: a multicenter retrospective study

Introduction

Pacemaker implantation is the treatment of choice for clinically relevant bradyarrhythmias. Pacemaker-lead-associated thrombosis (PLAT) occurs in 23.0–45.0% of people with permanent transvenous pacemakers. Serious thromboembolic complications are reported in 0.6–3.5%. The incidence of PLAT in dogs is unknown.

Animals, materials and methods

multicenter retrospective study of seven centers with 606 client-owned dogs undergoing permanent pacemaker implantation between 2012 and 2019. 260 dogs with a transvenous pacemaker with echocardiographic follow-up, 268 dogs with a transvenous pacemaker without echocardiographic follow-up and 78 dogs with an epicardial pacemaker.

Results

10.4% (27/260) of dogs with transvenous pacemakers and echocardiographic follow-up had PLAT identified. The median time to diagnosis was 175 days (6–1853 days). Pacemaker-lead-associated thrombosis was an incidental finding in 15/27 (55.6%) dogs. Of dogs with a urine protein:creatinine ratio measured at pacemaker implantation, dogs with PLAT were more likely to have proteinuria at pacemaker implantation vs. dogs without PLAT (6/6 (100.0%) vs. 21/52 (40.4%), P=0.007). Urine protein:creatinine ratio was measured in 12/27 (44.4%) dogs at PLAT diagnosis, with proteinuria identified in 10/12 (83.3%) dogs. Anti-thrombotic drugs were used following the identification of PLAT in 22/27 (81.5%) dogs. The thrombus resolved in 9/15 (60.0%) dogs in which follow-up echocardiography was performed. Dogs with PLAT had shorter survival times from implantation compared to those without PLAT (677 days [9–1988 days] vs. 1105 days [1–2661 days], P=0.003).

Conclusions

Pacemaker-lead-associated thrombosis is identified in 10.4% (27/260) of dogs following transvenous pacing, is associated with proteinuria, can cause significant morbidity, and is associated with reduced survival times.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Veterinary Cardiology
Journal of Veterinary Cardiology VETERINARY SCIENCES-
CiteScore
2.50
自引率
25.00%
发文量
66
审稿时长
154 days
期刊介绍: The mission of the Journal of Veterinary Cardiology is to publish peer-reviewed reports of the highest quality that promote greater understanding of cardiovascular disease, and enhance the health and well being of animals and humans. The Journal of Veterinary Cardiology publishes original contributions involving research and clinical practice that include prospective and retrospective studies, clinical trials, epidemiology, observational studies, and advances in applied and basic research. The Journal invites submission of original manuscripts. Specific content areas of interest include heart failure, arrhythmias, congenital heart disease, cardiovascular medicine, surgery, hypertension, health outcomes research, diagnostic imaging, interventional techniques, genetics, molecular cardiology, and cardiovascular pathology, pharmacology, and toxicology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信