中国使用皮下植入式心律转复除颤器的真实证据:单中心体验。

IF 1.1 4区 医学 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS
Herz Pub Date : 2023-12-01 Epub Date: 2023-08-04 DOI:10.1007/s00059-023-05192-4
Lei Zhang, Xiao Li, Yixiu Liang, Jingfeng Wang, Minghui Li, Lei Pan, Xueying Chen, Shengmei Qin, Jin Bai, Wei Wang, Yangang Su, Junbo Ge
{"title":"中国使用皮下植入式心律转复除颤器的真实证据:单中心体验。","authors":"Lei Zhang, Xiao Li, Yixiu Liang, Jingfeng Wang, Minghui Li, Lei Pan, Xueying Chen, Shengmei Qin, Jin Bai, Wei Wang, Yangang Su, Junbo Ge","doi":"10.1007/s00059-023-05192-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have been shown to be non-inferior to transvenous ICDs in the prevention of sudden cardiac death (SCD), but there is still a lack of evidence from clinical trials in China. We investigated whether S‑ICD implantation in the Chinese population is safe and feasible and should be promoted in the future.</p><p><strong>Methods: </strong>Consecutive patients undergoing S‑ICD implantation at our center were enrolled in this retrospective study. Data were collected within the median follow-up period of 554 days. Data concerning patient selection, implantation procedures, complications, and episodes of shock were analyzed.</p><p><strong>Results: </strong>In total, 70.2% of all 47 patients (median age = 39 years) were included for secondary prevention of SCD with different etiologies. Vector screening showed that 98% of patients were with > 1 appropriate vector in all postures. An intraoperative defibrillation test was not performed on six patients because of the high risk of disease deterioration, while all episodes of ventricular fibrillation induced post implantation were terminated by one shock. As expected, no severe complications (e.g., infection and device-related complications) were observed, except for one case of delayed healing of the incision. Overall, 15 patients (31.9%) experienced appropriate shocks (AS) with all episodes terminated by one shock. Two patients (4.3%) experienced inappropriate shocks (IAS) due to noise oversensing, resulting in a high Kaplan-Meier IAS-free rate of 95.7%.</p><p><strong>Conclusion: </strong>Based on appropriate patient selection and standardized implantation procedures, this real-world study confirmed the safety and efficacy of S‑ICD in Chinese patients, indicating that it may help to promote the prevention of SCD in China.</p>","PeriodicalId":12863,"journal":{"name":"Herz","volume":" ","pages":"462-469"},"PeriodicalIF":1.1000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Real-world evidence for the use of subcutaneous implantable cardioverter-defibrillators in China: A single-center experience.\",\"authors\":\"Lei Zhang, Xiao Li, Yixiu Liang, Jingfeng Wang, Minghui Li, Lei Pan, Xueying Chen, Shengmei Qin, Jin Bai, Wei Wang, Yangang Su, Junbo Ge\",\"doi\":\"10.1007/s00059-023-05192-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have been shown to be non-inferior to transvenous ICDs in the prevention of sudden cardiac death (SCD), but there is still a lack of evidence from clinical trials in China. We investigated whether S‑ICD implantation in the Chinese population is safe and feasible and should be promoted in the future.</p><p><strong>Methods: </strong>Consecutive patients undergoing S‑ICD implantation at our center were enrolled in this retrospective study. Data were collected within the median follow-up period of 554 days. Data concerning patient selection, implantation procedures, complications, and episodes of shock were analyzed.</p><p><strong>Results: </strong>In total, 70.2% of all 47 patients (median age = 39 years) were included for secondary prevention of SCD with different etiologies. Vector screening showed that 98% of patients were with > 1 appropriate vector in all postures. An intraoperative defibrillation test was not performed on six patients because of the high risk of disease deterioration, while all episodes of ventricular fibrillation induced post implantation were terminated by one shock. As expected, no severe complications (e.g., infection and device-related complications) were observed, except for one case of delayed healing of the incision. Overall, 15 patients (31.9%) experienced appropriate shocks (AS) with all episodes terminated by one shock. Two patients (4.3%) experienced inappropriate shocks (IAS) due to noise oversensing, resulting in a high Kaplan-Meier IAS-free rate of 95.7%.</p><p><strong>Conclusion: </strong>Based on appropriate patient selection and standardized implantation procedures, this real-world study confirmed the safety and efficacy of S‑ICD in Chinese patients, indicating that it may help to promote the prevention of SCD in China.</p>\",\"PeriodicalId\":12863,\"journal\":{\"name\":\"Herz\",\"volume\":\" \",\"pages\":\"462-469\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Herz\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00059-023-05192-4\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/8/4 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Herz","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00059-023-05192-4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/4 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:在预防心源性猝死(SCD)方面,皮下植入式心律转诊除颤器(S-ICDs)已被证明不逊于经静脉ICDs,但在中国仍缺乏临床试验证据。我们调查了S - ICD植入在中国人群中是否安全可行,是否应该在未来推广。方法:连续在本中心接受S - ICD植入的患者纳入本回顾性研究。数据收集的中位随访期为554天。我们分析了有关患者选择、植入程序、并发症和休克发作的数据。结果:47例患者(中位年龄 = 39岁)中,70.2%的患者被纳入不同病因的SCD二级预防。病媒筛查显示,98%的患者在所有体位中均有> 1个合适的病媒。由于疾病恶化的高风险,6例患者未进行术中除颤试验,而所有植入后引起的心室颤动发作均通过一次电击终止。正如预期的那样,除一例切口愈合延迟外,未观察到严重并发症(如感染和器械相关并发症)。总的来说,15名患者(31.9%)经历了适当的电击(AS),所有发作都以一次电击结束。2例患者(4.3%)由于噪声过度敏感而出现不适当电击(IAS),导致Kaplan-Meier IAS无发生率高达95.7%。结论:基于合适的患者选择和规范的植入程序,本现实世界的研究证实了S - ICD在中国患者中的安全性和有效性,表明它可能有助于促进中国SCD的预防。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Real-world evidence for the use of subcutaneous implantable cardioverter-defibrillators in China: A single-center experience.

Real-world evidence for the use of subcutaneous implantable cardioverter-defibrillators in China: A single-center experience.

Background: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have been shown to be non-inferior to transvenous ICDs in the prevention of sudden cardiac death (SCD), but there is still a lack of evidence from clinical trials in China. We investigated whether S‑ICD implantation in the Chinese population is safe and feasible and should be promoted in the future.

Methods: Consecutive patients undergoing S‑ICD implantation at our center were enrolled in this retrospective study. Data were collected within the median follow-up period of 554 days. Data concerning patient selection, implantation procedures, complications, and episodes of shock were analyzed.

Results: In total, 70.2% of all 47 patients (median age = 39 years) were included for secondary prevention of SCD with different etiologies. Vector screening showed that 98% of patients were with > 1 appropriate vector in all postures. An intraoperative defibrillation test was not performed on six patients because of the high risk of disease deterioration, while all episodes of ventricular fibrillation induced post implantation were terminated by one shock. As expected, no severe complications (e.g., infection and device-related complications) were observed, except for one case of delayed healing of the incision. Overall, 15 patients (31.9%) experienced appropriate shocks (AS) with all episodes terminated by one shock. Two patients (4.3%) experienced inappropriate shocks (IAS) due to noise oversensing, resulting in a high Kaplan-Meier IAS-free rate of 95.7%.

Conclusion: Based on appropriate patient selection and standardized implantation procedures, this real-world study confirmed the safety and efficacy of S‑ICD in Chinese patients, indicating that it may help to promote the prevention of SCD in China.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Herz
Herz 医学-心血管系统
CiteScore
3.00
自引率
5.90%
发文量
61
审稿时长
4-8 weeks
期刊介绍: Herz is the high-level journal for further education for all physicians interested in cardiology. The individual issues of the journal each deal with specific topics and comprise review articles in English and German written by competent and esteemed authors. They provide up-to-date and comprehensive information concerning the speciality dealt with in the issue. Due to the fact that all relevant aspects of the pertinent topic of an issue are considered, an overview of the current status and progress in cardiology is presented. Reviews and original articles round off the spectrum of information provided.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信