{"title":"锥形和平行种植体的插入扭矩和共振频率分析。","authors":"Joaquín de Elío Oliveros,&nbsp;Alejandro Gago García,&nbsp;Hernán López Sacristán,&nbsp;Patricia Truchuelo Díez,&nbsp;Cayetana Barrilero Martín,&nbsp;Mariano Del Canto Díaz,&nbsp;Mariano Del Canto Pingarrón","doi":"10.1563/aaid-joi-D-21-00305","DOIUrl":null,"url":null,"abstract":"<p><p>Primary implant stability (PIS) is known to vary with recipient bone mass and density, dental implant design and surgical technique. The objective of this preliminary study was to compare rotational and lateral PIS of same-coronal-diameter conical and parallel implants, using insertion torque recorded with a dental implant motor set and implant stability quotient obtained from resonance frequency analysis (performed with both Osstell and Penguin systems) as measures of rotational and lateral stability, respectively. Additionally, the relationship between PIS and alveolar ridge width (ARW) was explored in both implant types. Sixty dental implants (30 tapered and 30 parallel) were randomly placed with a split-mouth design in 17 patients. Bone density and ARW were estimated from cone beam computed tomography images taken with radiological-surgical templates. Density and width values were similar in the 2 groups (P > .05). Implant coronal diameters were 3.75 mm in all cases, while consistent with the manufacturer's recommendations, final drill bit diameters used were 3.25 and 3.4 mm for parallel and tapered implants, respectively. Insertion torque was higher (P < .05) with parallel implants, but between-group differences in implant stability quotient were not significant (P > .05). In tapered implants, insertion torque was inversely correlated with ARW (P < .001). Notably, significant differences were observed between resonance frequency analysis values from Osstell and Penguin systems (P < .001). In conclusion, future studies should explore how PIS may be influenced by final drill bit size regardless of implant design and potential limits on the effectiveness of tapered implants to achieve good stability in thick low-density bone.</p>","PeriodicalId":50101,"journal":{"name":"Journal of Oral Implantology","volume":"49 4","pages":"347-354"},"PeriodicalIF":1.5000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Insertion Torque and Resonance Frequency Analysis in Tapered and Parallel Dental Implants.\",\"authors\":\"Joaquín de Elío Oliveros,&nbsp;Alejandro Gago García,&nbsp;Hernán López Sacristán,&nbsp;Patricia Truchuelo Díez,&nbsp;Cayetana Barrilero Martín,&nbsp;Mariano Del Canto Díaz,&nbsp;Mariano Del Canto Pingarrón\",\"doi\":\"10.1563/aaid-joi-D-21-00305\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Primary implant stability (PIS) is known to vary with recipient bone mass and density, dental implant design and surgical technique. The objective of this preliminary study was to compare rotational and lateral PIS of same-coronal-diameter conical and parallel implants, using insertion torque recorded with a dental implant motor set and implant stability quotient obtained from resonance frequency analysis (performed with both Osstell and Penguin systems) as measures of rotational and lateral stability, respectively. Additionally, the relationship between PIS and alveolar ridge width (ARW) was explored in both implant types. Sixty dental implants (30 tapered and 30 parallel) were randomly placed with a split-mouth design in 17 patients. Bone density and ARW were estimated from cone beam computed tomography images taken with radiological-surgical templates. Density and width values were similar in the 2 groups (P > .05). Implant coronal diameters were 3.75 mm in all cases, while consistent with the manufacturer's recommendations, final drill bit diameters used were 3.25 and 3.4 mm for parallel and tapered implants, respectively. Insertion torque was higher (P < .05) with parallel implants, but between-group differences in implant stability quotient were not significant (P > .05). In tapered implants, insertion torque was inversely correlated with ARW (P < .001). Notably, significant differences were observed between resonance frequency analysis values from Osstell and Penguin systems (P < .001). In conclusion, future studies should explore how PIS may be influenced by final drill bit size regardless of implant design and potential limits on the effectiveness of tapered implants to achieve good stability in thick low-density bone.</p>\",\"PeriodicalId\":50101,\"journal\":{\"name\":\"Journal of Oral Implantology\",\"volume\":\"49 4\",\"pages\":\"347-354\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Oral Implantology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1563/aaid-joi-D-21-00305\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Oral Implantology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1563/aaid-joi-D-21-00305","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

摘要

初级种植体稳定性(PIS)是已知的变化与受体骨量和密度,牙种植体设计和手术技术。本初步研究的目的是比较相同冠径的锥形种植体和平行种植体的旋转和侧向PIS,分别使用牙种植体电机组记录的插入扭矩和通过共振频率分析获得的种植体稳定商(使用Osstell和Penguin系统进行)作为旋转和侧向稳定性的测量。此外,我们还探讨了两种种植体中PIS与牙槽嵴宽度(ARW)的关系。在17例患者中,60个种植体(30个锥形和30个平行)随机放置在开口设计中。骨密度和ARW是通过使用放射外科模板拍摄的锥束计算机断层扫描图像来估计的。两组间密度、宽度值比较,差异无统计学意义(P > 0.05)。所有情况下种植体冠状直径均为3.75 mm,而与制造商的建议一致,平行种植体和锥形种植体的最终钻头直径分别为3.25和3.4 mm。平行种植体的植入扭矩更高(P < 0.05),但种植体稳定性商组间差异无统计学意义(P > 0.05)。在锥形种植体中,插入扭矩与ARW呈负相关(P < 0.001)。值得注意的是,在Osstell系统和Penguin系统的共振频率分析值之间观察到显著差异(P < 0.001)。总之,未来的研究应探讨PIS如何受到最终钻头尺寸的影响,而不考虑种植体的设计以及锥形种植体在厚低密度骨中获得良好稳定性的有效性的潜在限制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Insertion Torque and Resonance Frequency Analysis in Tapered and Parallel Dental Implants.

Primary implant stability (PIS) is known to vary with recipient bone mass and density, dental implant design and surgical technique. The objective of this preliminary study was to compare rotational and lateral PIS of same-coronal-diameter conical and parallel implants, using insertion torque recorded with a dental implant motor set and implant stability quotient obtained from resonance frequency analysis (performed with both Osstell and Penguin systems) as measures of rotational and lateral stability, respectively. Additionally, the relationship between PIS and alveolar ridge width (ARW) was explored in both implant types. Sixty dental implants (30 tapered and 30 parallel) were randomly placed with a split-mouth design in 17 patients. Bone density and ARW were estimated from cone beam computed tomography images taken with radiological-surgical templates. Density and width values were similar in the 2 groups (P > .05). Implant coronal diameters were 3.75 mm in all cases, while consistent with the manufacturer's recommendations, final drill bit diameters used were 3.25 and 3.4 mm for parallel and tapered implants, respectively. Insertion torque was higher (P < .05) with parallel implants, but between-group differences in implant stability quotient were not significant (P > .05). In tapered implants, insertion torque was inversely correlated with ARW (P < .001). Notably, significant differences were observed between resonance frequency analysis values from Osstell and Penguin systems (P < .001). In conclusion, future studies should explore how PIS may be influenced by final drill bit size regardless of implant design and potential limits on the effectiveness of tapered implants to achieve good stability in thick low-density bone.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Oral Implantology
Journal of Oral Implantology DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.30
自引率
6.20%
发文量
54
审稿时长
6-12 weeks
期刊介绍: The official publication of the American Academy of Implant Dentistry and of the American Academy of Implant Prosthodontics, is dedicated to providing valuable information to general dentists, oral surgeons, prosthodontists, periodontists, scientists, clinicians, laboratory owners and technicians, manufacturers, and educators. Implant basics, prosthetics, pharmaceuticals, the latest research in implantology, implant surgery, and advanced implant procedures are just some of the topics covered.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信