适合消防靴:使用计算机断层扫描技术探索内部形态。

IF 1.6 4区 医学 Q3 ERGONOMICS
Jeyeon Jo, Huiju Park
{"title":"适合消防靴:使用计算机断层扫描技术探索内部形态。","authors":"Jeyeon Jo, Huiju Park","doi":"10.1080/10803548.2023.2247765","DOIUrl":null,"url":null,"abstract":"<p><p>Fit of fire boots is a crucial factor in the safety and performance of firefighters on the hostile fireground. Firefighters have reported that ill-fitting fire boots restrict their lower body movement and sometimes cause very dangerous situations by falling off behind the wearer. By using computed tomography, this study demonstrates the potential to quantify and visualize the fit of fire boots, which previously relied on subjective feedback from the wearers. The high-resolution three-dimensional (3D) models of two fire boot products allowed a detailed observation and measurement of the internal space of the boots. Also, the boot's internal dimension was compared to the foot measurement of local firefighters, showing the significant differences between the two boots. Lastly, simulation wrapping the 3D scanned foot with the boot revealed large void spaces around the toe box and ankle, as well as the narrower ball width of the boot than the foot.</p>","PeriodicalId":47704,"journal":{"name":"International Journal of Occupational Safety and Ergonomics","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fit of fire boots: exploring internal morphology using computed tomography.\",\"authors\":\"Jeyeon Jo, Huiju Park\",\"doi\":\"10.1080/10803548.2023.2247765\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Fit of fire boots is a crucial factor in the safety and performance of firefighters on the hostile fireground. Firefighters have reported that ill-fitting fire boots restrict their lower body movement and sometimes cause very dangerous situations by falling off behind the wearer. By using computed tomography, this study demonstrates the potential to quantify and visualize the fit of fire boots, which previously relied on subjective feedback from the wearers. The high-resolution three-dimensional (3D) models of two fire boot products allowed a detailed observation and measurement of the internal space of the boots. Also, the boot's internal dimension was compared to the foot measurement of local firefighters, showing the significant differences between the two boots. Lastly, simulation wrapping the 3D scanned foot with the boot revealed large void spaces around the toe box and ankle, as well as the narrower ball width of the boot than the foot.</p>\",\"PeriodicalId\":47704,\"journal\":{\"name\":\"International Journal of Occupational Safety and Ergonomics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Occupational Safety and Ergonomics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/10803548.2023.2247765\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/10/5 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ERGONOMICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Occupational Safety and Ergonomics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/10803548.2023.2247765","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/5 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ERGONOMICS","Score":null,"Total":0}
引用次数: 0

摘要

消防靴的合身程度是消防员在敌对火场上安全和表现的关键因素。消防员报告说,不合身的消防靴限制了他们的下半身运动,有时会从穿着者身后脱落,造成非常危险的情况。通过使用计算机断层扫描,这项研究证明了量化和可视化消防靴贴合度的潜力,而消防靴的贴合度以前依赖于穿着者的主观反馈。两款消防靴产品的高分辨率三维(3D)模型可以对消防靴的内部空间进行详细观察和测量。此外,还将靴子的内部尺寸与当地消防员的脚部尺寸进行了比较,显示了两种靴子之间的显著差异。最后,用靴子包裹3D扫描的脚的模拟显示,鞋头和脚踝周围有很大的空隙,而且靴子的球宽比脚窄。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fit of fire boots: exploring internal morphology using computed tomography.

Fit of fire boots is a crucial factor in the safety and performance of firefighters on the hostile fireground. Firefighters have reported that ill-fitting fire boots restrict their lower body movement and sometimes cause very dangerous situations by falling off behind the wearer. By using computed tomography, this study demonstrates the potential to quantify and visualize the fit of fire boots, which previously relied on subjective feedback from the wearers. The high-resolution three-dimensional (3D) models of two fire boot products allowed a detailed observation and measurement of the internal space of the boots. Also, the boot's internal dimension was compared to the foot measurement of local firefighters, showing the significant differences between the two boots. Lastly, simulation wrapping the 3D scanned foot with the boot revealed large void spaces around the toe box and ankle, as well as the narrower ball width of the boot than the foot.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.80
自引率
8.30%
发文量
152
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信