Hedwig M J M Nies, Bibi Martens, Suzanne Gommers, Geertruida P Bijvoet, Joachim E Wildberger, Rachel M A Ter Bekke, Robert J Holtackers, Casper Mihl
{"title":"使用高分辨率自由呼吸3D暗血和标准屏息2D亮血晚期钆增强MRI检测心肌瘢痕:观察者置信度的比较。","authors":"Hedwig M J M Nies, Bibi Martens, Suzanne Gommers, Geertruida P Bijvoet, Joachim E Wildberger, Rachel M A Ter Bekke, Robert J Holtackers, Casper Mihl","doi":"10.1097/RMR.0000000000000304","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare observer confidence for myocardial scar detection using 3 different late gadolinium enhancement (LGE) data sets by 2 observers with different levels of experience.</p><p><strong>Materials and methods: </strong>Forty-one consecutive patients, who were referred for 3D dark-blood LGE MRI before implantable cardioverter-defibrillator implantation or ablation therapy and who underwent 2D bright-blood LGE MRI within a time frame of 3 months, were prospectively included. From all 3D dark-blood LGE data sets, a stack of 2D short-axis slices was reconstructed. All acquired LGE data sets were anonymized and randomized and evaluated by 2 independent observers with different levels of experience in cardiovascular imaging (beginner and expert). Confidence in detection of ischemic scar, nonischemic scar, papillary muscle scar, and right ventricular scar for each LGE data set was scored using a using a 3-point Likert scale (1 = low, 2 = medium, or 3 = high). Observer confidence scores were compared using the Friedman omnibus test and Wilcoxon signed-rank post hoc test.</p><p><strong>Results: </strong>For the beginner observer, a significant difference in confidence regarding ischemic scar detection was observed in favor of reconstructed 2D dark-blood LGE compared with standard 2D bright-blood LGE (p = 0.030) while for the expert observer, no significant difference was found (p = 0.166). Similarly, for right ventricular scar detection, a significant difference in confidence was observed in favor of reconstructed 2D dark-blood LGE compared with standard 2D bright-blood LGE (p = 0.006) while for the expert observer, no significant difference was found (p = 0.662). Although not significantly different for other areas of interest, 3D dark-blood LGE and its derived 2D dark-blood LGE data set showed a tendency to score higher for all areas of interest at both experience levels.</p><p><strong>Conclusions: </strong>The combination of dark-blood LGE contrast and high isotropic voxels may contribute to increased observer confidence in myocardial scar detection, independent of observer's experience level but in particular for beginner observers.</p>","PeriodicalId":39381,"journal":{"name":"Topics in Magnetic Resonance Imaging","volume":"32 3","pages":"27-32"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/1d/7d/tmri-32-27.PMC10510822.pdf","citationCount":"0","resultStr":"{\"title\":\"Myocardial Scar Detection Using High-Resolution Free-Breathing 3D Dark-Blood and Standard Breath-Holding 2D Bright-Blood Late Gadolinium Enhancement MRI: A Comparison of Observer Confidence.\",\"authors\":\"Hedwig M J M Nies, Bibi Martens, Suzanne Gommers, Geertruida P Bijvoet, Joachim E Wildberger, Rachel M A Ter Bekke, Robert J Holtackers, Casper Mihl\",\"doi\":\"10.1097/RMR.0000000000000304\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To compare observer confidence for myocardial scar detection using 3 different late gadolinium enhancement (LGE) data sets by 2 observers with different levels of experience.</p><p><strong>Materials and methods: </strong>Forty-one consecutive patients, who were referred for 3D dark-blood LGE MRI before implantable cardioverter-defibrillator implantation or ablation therapy and who underwent 2D bright-blood LGE MRI within a time frame of 3 months, were prospectively included. From all 3D dark-blood LGE data sets, a stack of 2D short-axis slices was reconstructed. All acquired LGE data sets were anonymized and randomized and evaluated by 2 independent observers with different levels of experience in cardiovascular imaging (beginner and expert). Confidence in detection of ischemic scar, nonischemic scar, papillary muscle scar, and right ventricular scar for each LGE data set was scored using a using a 3-point Likert scale (1 = low, 2 = medium, or 3 = high). Observer confidence scores were compared using the Friedman omnibus test and Wilcoxon signed-rank post hoc test.</p><p><strong>Results: </strong>For the beginner observer, a significant difference in confidence regarding ischemic scar detection was observed in favor of reconstructed 2D dark-blood LGE compared with standard 2D bright-blood LGE (p = 0.030) while for the expert observer, no significant difference was found (p = 0.166). Similarly, for right ventricular scar detection, a significant difference in confidence was observed in favor of reconstructed 2D dark-blood LGE compared with standard 2D bright-blood LGE (p = 0.006) while for the expert observer, no significant difference was found (p = 0.662). Although not significantly different for other areas of interest, 3D dark-blood LGE and its derived 2D dark-blood LGE data set showed a tendency to score higher for all areas of interest at both experience levels.</p><p><strong>Conclusions: </strong>The combination of dark-blood LGE contrast and high isotropic voxels may contribute to increased observer confidence in myocardial scar detection, independent of observer's experience level but in particular for beginner observers.</p>\",\"PeriodicalId\":39381,\"journal\":{\"name\":\"Topics in Magnetic Resonance Imaging\",\"volume\":\"32 3\",\"pages\":\"27-32\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/1d/7d/tmri-32-27.PMC10510822.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Topics in Magnetic Resonance Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/RMR.0000000000000304\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/4/16 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Topics in Magnetic Resonance Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/RMR.0000000000000304","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/4/16 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
Myocardial Scar Detection Using High-Resolution Free-Breathing 3D Dark-Blood and Standard Breath-Holding 2D Bright-Blood Late Gadolinium Enhancement MRI: A Comparison of Observer Confidence.
Objective: To compare observer confidence for myocardial scar detection using 3 different late gadolinium enhancement (LGE) data sets by 2 observers with different levels of experience.
Materials and methods: Forty-one consecutive patients, who were referred for 3D dark-blood LGE MRI before implantable cardioverter-defibrillator implantation or ablation therapy and who underwent 2D bright-blood LGE MRI within a time frame of 3 months, were prospectively included. From all 3D dark-blood LGE data sets, a stack of 2D short-axis slices was reconstructed. All acquired LGE data sets were anonymized and randomized and evaluated by 2 independent observers with different levels of experience in cardiovascular imaging (beginner and expert). Confidence in detection of ischemic scar, nonischemic scar, papillary muscle scar, and right ventricular scar for each LGE data set was scored using a using a 3-point Likert scale (1 = low, 2 = medium, or 3 = high). Observer confidence scores were compared using the Friedman omnibus test and Wilcoxon signed-rank post hoc test.
Results: For the beginner observer, a significant difference in confidence regarding ischemic scar detection was observed in favor of reconstructed 2D dark-blood LGE compared with standard 2D bright-blood LGE (p = 0.030) while for the expert observer, no significant difference was found (p = 0.166). Similarly, for right ventricular scar detection, a significant difference in confidence was observed in favor of reconstructed 2D dark-blood LGE compared with standard 2D bright-blood LGE (p = 0.006) while for the expert observer, no significant difference was found (p = 0.662). Although not significantly different for other areas of interest, 3D dark-blood LGE and its derived 2D dark-blood LGE data set showed a tendency to score higher for all areas of interest at both experience levels.
Conclusions: The combination of dark-blood LGE contrast and high isotropic voxels may contribute to increased observer confidence in myocardial scar detection, independent of observer's experience level but in particular for beginner observers.
期刊介绍:
Topics in Magnetic Resonance Imaging is a leading information resource for professionals in the MRI community. This publication supplies authoritative, up-to-the-minute coverage of technical advances in this evolving field as well as practical, hands-on guidance from leading experts. Six times a year, TMRI focuses on a single timely topic of interest to radiologists. These topical issues present a variety of perspectives from top radiological authorities to provide an in-depth understanding of how MRI is being used in each area.