术中透视放射在骨科创伤中的应用:与手术类型和外科医生经验的关系。

Luís Fabião, Ana Ribau, Carolina Lemos, Ricardo Rodrigues-Pinto
{"title":"术中透视放射在骨科创伤中的应用:与手术类型和外科医生经验的关系。","authors":"Luís Fabião,&nbsp;Ana Ribau,&nbsp;Carolina Lemos,&nbsp;Ricardo Rodrigues-Pinto","doi":"10.1097/j.pbj.0000000000000218","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>While fluoroscopy is widely used in orthopedic trauma surgeries, it is associated with harmful effects and should, therefore, be minimized. However, reference values for these surgeries have not been defined, and it is not known how surgeon experience affects these factors. The aims of this study were to analyze the radiation emitted and exposure time for common orthopedic trauma surgeries and to assess whether they are affected by surgeon experience.</p><p><strong>Methods: </strong>Data from 1842 trauma orthopedic procedures were retrospectively analyzed. A total of 1421 procedures were included in the analysis. Radiation dose and time were collected to identify reference values for each surgery and compared for when the lead surgeon was a young resident, a senior resident, or a specialist.</p><p><strong>Results: </strong>The most performed surgeries requiring fluoroscopy were proximal femur short intramedullary nailing (n = 401), ankle open reduction and internal fixation (ORIF) (n = 141), distal radius ORIF (n = 125), and proximal femur dynamic hip screw (DHS) (n = 114). Surgeries using higher radiation dose were proximal femur long intramedullary nailing (mean dose area [DAP]): 1361.35 mGycm<sup>2</sup>), proximal femur DHS (1094.81 mGycm<sup>2</sup>), and proximal femur short intramedullary nailing (891.41 mGycm<sup>2</sup>). Surgeries requiring longer radiation time were proximal humerus and/or humeral shaft intramedullary nailing (02 mm:20 ss), proximal femur long intramedullary nailing (02 mm:04 ss), and tibial shaft/distal tibia intramedullary nailing (01 mm:49 ss). Senior residents required shorter radiation time when performing short intramedullary nailing of the proximal femur than young residents. Specialists required more radiation dose than residents when performing tibial nailing and tibial plateau ORIF and required longer radiation time than young residents when performing tibial nailing.</p><p><strong>Conclusions: </strong>This study presents mean values of radiation dose and time for common orthopedic trauma surgeries. Orthopedic surgeon experience influences radiation dose and time values. Contrary to expected, less experience is associated with lower values in some of the cases analyzed.</p>","PeriodicalId":74479,"journal":{"name":"Porto biomedical journal","volume":"8 3","pages":"e218"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/0e/26/pj9-8-e218.PMC10289723.pdf","citationCount":"1","resultStr":"{\"title\":\"Intraoperative fluoroscopic radiation in orthopedic trauma: correlation with surgery type and surgeon experience.\",\"authors\":\"Luís Fabião,&nbsp;Ana Ribau,&nbsp;Carolina Lemos,&nbsp;Ricardo Rodrigues-Pinto\",\"doi\":\"10.1097/j.pbj.0000000000000218\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>While fluoroscopy is widely used in orthopedic trauma surgeries, it is associated with harmful effects and should, therefore, be minimized. However, reference values for these surgeries have not been defined, and it is not known how surgeon experience affects these factors. The aims of this study were to analyze the radiation emitted and exposure time for common orthopedic trauma surgeries and to assess whether they are affected by surgeon experience.</p><p><strong>Methods: </strong>Data from 1842 trauma orthopedic procedures were retrospectively analyzed. A total of 1421 procedures were included in the analysis. Radiation dose and time were collected to identify reference values for each surgery and compared for when the lead surgeon was a young resident, a senior resident, or a specialist.</p><p><strong>Results: </strong>The most performed surgeries requiring fluoroscopy were proximal femur short intramedullary nailing (n = 401), ankle open reduction and internal fixation (ORIF) (n = 141), distal radius ORIF (n = 125), and proximal femur dynamic hip screw (DHS) (n = 114). Surgeries using higher radiation dose were proximal femur long intramedullary nailing (mean dose area [DAP]): 1361.35 mGycm<sup>2</sup>), proximal femur DHS (1094.81 mGycm<sup>2</sup>), and proximal femur short intramedullary nailing (891.41 mGycm<sup>2</sup>). Surgeries requiring longer radiation time were proximal humerus and/or humeral shaft intramedullary nailing (02 mm:20 ss), proximal femur long intramedullary nailing (02 mm:04 ss), and tibial shaft/distal tibia intramedullary nailing (01 mm:49 ss). Senior residents required shorter radiation time when performing short intramedullary nailing of the proximal femur than young residents. Specialists required more radiation dose than residents when performing tibial nailing and tibial plateau ORIF and required longer radiation time than young residents when performing tibial nailing.</p><p><strong>Conclusions: </strong>This study presents mean values of radiation dose and time for common orthopedic trauma surgeries. Orthopedic surgeon experience influences radiation dose and time values. Contrary to expected, less experience is associated with lower values in some of the cases analyzed.</p>\",\"PeriodicalId\":74479,\"journal\":{\"name\":\"Porto biomedical journal\",\"volume\":\"8 3\",\"pages\":\"e218\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/0e/26/pj9-8-e218.PMC10289723.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Porto biomedical journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/j.pbj.0000000000000218\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Porto biomedical journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/j.pbj.0000000000000218","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

背景:虽然透视在骨科创伤手术中被广泛应用,但它与有害影响相关,因此应尽量减少。然而,这些手术的参考值尚未确定,也不知道外科医生的经验如何影响这些因素。本研究的目的是分析普通骨科创伤手术的辐射和照射时间,并评估它们是否受到外科医生经验的影响。方法:回顾性分析1842例创伤骨科手术的资料。共有1421个程序被纳入分析。收集辐射剂量和时间,以确定每次手术的参考值,并与主要外科医生是年轻住院医师、资深住院医师或专科医生时进行比较。结果:需要透视的手术最多的是股骨近端短髓内钉(n = 401)、踝关节切开复位内固定(n = 141)、桡骨远端ORIF (n = 125)和股骨近端动力髋螺钉(n = 114)。采用较高放射剂量的手术为股骨近端长髓内钉(平均剂量面积[DAP]: 1361.35 mGycm2)、股骨近端DHS (1094.81 mGycm2)和股骨近端短髓内钉(891.41 mGycm2)。需要较长放射时间的手术是肱骨近端和/或肱骨骨干髓内钉(02 mm:20秒)、股骨近端长髓内钉(02 mm:04秒)和胫骨骨干/胫骨远端髓内钉(01 mm:49秒)。老年住院医师行股骨近端短髓内钉所需的放射时间比年轻住院医师短。专科医生在进行胫骨钉钉和胫骨平台ORIF时需要的辐射剂量高于住院医师,在进行胫骨钉钉时需要的辐射时间长于年轻住院医师。结论:本研究给出了普通骨科创伤手术放射剂量和时间的平均值。骨科医生的经验影响辐射剂量和时间值。与预期相反,在分析的一些案例中,较少的经验与较低的值相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Intraoperative fluoroscopic radiation in orthopedic trauma: correlation with surgery type and surgeon experience.

Intraoperative fluoroscopic radiation in orthopedic trauma: correlation with surgery type and surgeon experience.

Intraoperative fluoroscopic radiation in orthopedic trauma: correlation with surgery type and surgeon experience.

Background: While fluoroscopy is widely used in orthopedic trauma surgeries, it is associated with harmful effects and should, therefore, be minimized. However, reference values for these surgeries have not been defined, and it is not known how surgeon experience affects these factors. The aims of this study were to analyze the radiation emitted and exposure time for common orthopedic trauma surgeries and to assess whether they are affected by surgeon experience.

Methods: Data from 1842 trauma orthopedic procedures were retrospectively analyzed. A total of 1421 procedures were included in the analysis. Radiation dose and time were collected to identify reference values for each surgery and compared for when the lead surgeon was a young resident, a senior resident, or a specialist.

Results: The most performed surgeries requiring fluoroscopy were proximal femur short intramedullary nailing (n = 401), ankle open reduction and internal fixation (ORIF) (n = 141), distal radius ORIF (n = 125), and proximal femur dynamic hip screw (DHS) (n = 114). Surgeries using higher radiation dose were proximal femur long intramedullary nailing (mean dose area [DAP]): 1361.35 mGycm2), proximal femur DHS (1094.81 mGycm2), and proximal femur short intramedullary nailing (891.41 mGycm2). Surgeries requiring longer radiation time were proximal humerus and/or humeral shaft intramedullary nailing (02 mm:20 ss), proximal femur long intramedullary nailing (02 mm:04 ss), and tibial shaft/distal tibia intramedullary nailing (01 mm:49 ss). Senior residents required shorter radiation time when performing short intramedullary nailing of the proximal femur than young residents. Specialists required more radiation dose than residents when performing tibial nailing and tibial plateau ORIF and required longer radiation time than young residents when performing tibial nailing.

Conclusions: This study presents mean values of radiation dose and time for common orthopedic trauma surgeries. Orthopedic surgeon experience influences radiation dose and time values. Contrary to expected, less experience is associated with lower values in some of the cases analyzed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信