一种基于发光共价有机框架的“开-关-开”荧光开关,用于草甘膦的快速选择性检测。

IF 4.3 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC
Jiaxuan Fan, Jing Li, Wenfeng Zhou, Haixiang Gao, Runhua Lu, Hongchao Guo
{"title":"一种基于发光共价有机框架的“开-关-开”荧光开关,用于草甘膦的快速选择性检测。","authors":"Jiaxuan Fan,&nbsp;Jing Li,&nbsp;Wenfeng Zhou,&nbsp;Haixiang Gao,&nbsp;Runhua Lu,&nbsp;Hongchao Guo","doi":"10.1002/bio.4549","DOIUrl":null,"url":null,"abstract":"<p>Glyphosate, the most used herbicide in the world, has a residue problem that cannot be ignored. However, glyphosate itself does not have fluorescence emission and lacks the conditions for fluorescence detection. In this work, a rapid and selective fluorescence detection method of glyphosate was designed by an ‘on–off–on’ fluorescent switch based on a luminous covalent organic framework (L-COF). Only the fixed concentration of Fe<sup>3+</sup> as an intermediate could trigger the fluorescent switch and no incubation step was required. The proposed method showed good accuracy with a correlation coefficient of 0.9978. The method's limits of detection and quantitation were 0.88 and 2.93 μmol/L, which were lower than the maximum allowable residue limits in some regulations. Environmental water samples and tomatoes were selected as actual samples to verify the application in a complex matrix. A satisfactory mean recovery from 87% to 106% was gained. Furthermore, Fe<sup>3+</sup> could induce fluorescence quenching of L-COF through the photo-induced electron transfer (PET) effect, while the addition of glyphosate could block the PET effect to achieve detection. These results demonstrated the proposed method had abilities to detect glyphosate and broaden the application of L-COF.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2023-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An ‘on–off–on’ fluorescent switch based on a luminous covalent organic framework for the rapid and selective detection of glyphosate\",\"authors\":\"Jiaxuan Fan,&nbsp;Jing Li,&nbsp;Wenfeng Zhou,&nbsp;Haixiang Gao,&nbsp;Runhua Lu,&nbsp;Hongchao Guo\",\"doi\":\"10.1002/bio.4549\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Glyphosate, the most used herbicide in the world, has a residue problem that cannot be ignored. However, glyphosate itself does not have fluorescence emission and lacks the conditions for fluorescence detection. In this work, a rapid and selective fluorescence detection method of glyphosate was designed by an ‘on–off–on’ fluorescent switch based on a luminous covalent organic framework (L-COF). Only the fixed concentration of Fe<sup>3+</sup> as an intermediate could trigger the fluorescent switch and no incubation step was required. The proposed method showed good accuracy with a correlation coefficient of 0.9978. The method's limits of detection and quantitation were 0.88 and 2.93 μmol/L, which were lower than the maximum allowable residue limits in some regulations. Environmental water samples and tomatoes were selected as actual samples to verify the application in a complex matrix. A satisfactory mean recovery from 87% to 106% was gained. Furthermore, Fe<sup>3+</sup> could induce fluorescence quenching of L-COF through the photo-induced electron transfer (PET) effect, while the addition of glyphosate could block the PET effect to achieve detection. These results demonstrated the proposed method had abilities to detect glyphosate and broaden the application of L-COF.</p>\",\"PeriodicalId\":3,\"journal\":{\"name\":\"ACS Applied Electronic Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2023-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Electronic Materials\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/bio.4549\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"92","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/bio.4549","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

草甘膦是世界上使用最多的除草剂,其残留问题不容忽视。然而,草甘膦本身不具有荧光发射,并且缺乏荧光检测的条件。在这项工作中,通过基于发光共价有机框架(L-COF)的“开-关-开”荧光开关,设计了一种快速、选择性的草甘膦荧光检测方法。只有固定浓度的Fe3+作为中间体才能触发荧光开关,并且不需要培养步骤。该方法具有良好的准确性,相关系数为0.9978。该方法的检测和定量限分别为0.88和2.93 μmol/L,低于某些规定的最大允许残留限量。选择环境水样和番茄作为实际样品,以验证其在复杂基质中的应用。获得了令人满意的平均回收率,从87%到106%。此外,Fe3+可以通过光诱导电子转移(PET)效应诱导L-COF的荧光猝灭,而草甘膦的加入可以阻断PET效应以实现检测。这些结果表明,该方法具有检测草甘膦的能力,拓宽了L-COF的应用范围。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An ‘on–off–on’ fluorescent switch based on a luminous covalent organic framework for the rapid and selective detection of glyphosate

Glyphosate, the most used herbicide in the world, has a residue problem that cannot be ignored. However, glyphosate itself does not have fluorescence emission and lacks the conditions for fluorescence detection. In this work, a rapid and selective fluorescence detection method of glyphosate was designed by an ‘on–off–on’ fluorescent switch based on a luminous covalent organic framework (L-COF). Only the fixed concentration of Fe3+ as an intermediate could trigger the fluorescent switch and no incubation step was required. The proposed method showed good accuracy with a correlation coefficient of 0.9978. The method's limits of detection and quantitation were 0.88 and 2.93 μmol/L, which were lower than the maximum allowable residue limits in some regulations. Environmental water samples and tomatoes were selected as actual samples to verify the application in a complex matrix. A satisfactory mean recovery from 87% to 106% was gained. Furthermore, Fe3+ could induce fluorescence quenching of L-COF through the photo-induced electron transfer (PET) effect, while the addition of glyphosate could block the PET effect to achieve detection. These results demonstrated the proposed method had abilities to detect glyphosate and broaden the application of L-COF.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信