{"title":"开发相对简单的样品预处理策略,从液体口服药物成品中选择性去除聚山梨醇酯 80 的色谱干扰峰。","authors":"Sarju Adhikari, Shane N Berger, Abu M Rustum","doi":"10.1093/chromsci/bmad064","DOIUrl":null,"url":null,"abstract":"<p><p>Polysorbate 80 (PS 80) is a nonionic surfactant, used in myriad of pharmaceutical, food and cosmetic formulations. PS 80 components have strong UV absorbance and retain under reversed-phase chromatographic conditions, significantly masking sections of the chromatogram. PS 80-related peaks interferences in a sample are common and can be difficult to separate from the analyte peaks. A liquid oral finished product (LOFP) containing PS 80 and Ivermectin as the active pharmaceutical ingredient (API) was selected for this study. Herein, we report two sample pretreatment strategies focusing on the selective removal of PS 80 from the LOFP. Both methods significantly reduce and/or practically eliminate excipients and PS 80-related peaks interferences from the LOFP without a negative impact on the API and its key-related substances recovery. The solid-phase extraction (SPE) strategy uses a C18 SPE followed by a silica gel SPE, whereas the liquid-liquid extraction strategy uses in situ-generated sodium caprylate for the removal of formulation excipients and PS 80. These methods can significantly increase the reliability of high-performance liquid chromatography methods and decrease false positive out-of-specifications events because of coelution of PS 80-related peaks with peaks of interest.</p>","PeriodicalId":15430,"journal":{"name":"Journal of chromatographic science","volume":" ","pages":"593-599"},"PeriodicalIF":1.5000,"publicationDate":"2024-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of Relatively Simple Sample Pretreatment Strategies to Selectively Remove Chromatographic Interfering Peaks of Polysorbate 80 from Liquid Oral Finished Drug Product.\",\"authors\":\"Sarju Adhikari, Shane N Berger, Abu M Rustum\",\"doi\":\"10.1093/chromsci/bmad064\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Polysorbate 80 (PS 80) is a nonionic surfactant, used in myriad of pharmaceutical, food and cosmetic formulations. PS 80 components have strong UV absorbance and retain under reversed-phase chromatographic conditions, significantly masking sections of the chromatogram. PS 80-related peaks interferences in a sample are common and can be difficult to separate from the analyte peaks. A liquid oral finished product (LOFP) containing PS 80 and Ivermectin as the active pharmaceutical ingredient (API) was selected for this study. Herein, we report two sample pretreatment strategies focusing on the selective removal of PS 80 from the LOFP. Both methods significantly reduce and/or practically eliminate excipients and PS 80-related peaks interferences from the LOFP without a negative impact on the API and its key-related substances recovery. The solid-phase extraction (SPE) strategy uses a C18 SPE followed by a silica gel SPE, whereas the liquid-liquid extraction strategy uses in situ-generated sodium caprylate for the removal of formulation excipients and PS 80. These methods can significantly increase the reliability of high-performance liquid chromatography methods and decrease false positive out-of-specifications events because of coelution of PS 80-related peaks with peaks of interest.</p>\",\"PeriodicalId\":15430,\"journal\":{\"name\":\"Journal of chromatographic science\",\"volume\":\" \",\"pages\":\"593-599\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of chromatographic science\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1093/chromsci/bmad064\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of chromatographic science","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1093/chromsci/bmad064","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Development of Relatively Simple Sample Pretreatment Strategies to Selectively Remove Chromatographic Interfering Peaks of Polysorbate 80 from Liquid Oral Finished Drug Product.
Polysorbate 80 (PS 80) is a nonionic surfactant, used in myriad of pharmaceutical, food and cosmetic formulations. PS 80 components have strong UV absorbance and retain under reversed-phase chromatographic conditions, significantly masking sections of the chromatogram. PS 80-related peaks interferences in a sample are common and can be difficult to separate from the analyte peaks. A liquid oral finished product (LOFP) containing PS 80 and Ivermectin as the active pharmaceutical ingredient (API) was selected for this study. Herein, we report two sample pretreatment strategies focusing on the selective removal of PS 80 from the LOFP. Both methods significantly reduce and/or practically eliminate excipients and PS 80-related peaks interferences from the LOFP without a negative impact on the API and its key-related substances recovery. The solid-phase extraction (SPE) strategy uses a C18 SPE followed by a silica gel SPE, whereas the liquid-liquid extraction strategy uses in situ-generated sodium caprylate for the removal of formulation excipients and PS 80. These methods can significantly increase the reliability of high-performance liquid chromatography methods and decrease false positive out-of-specifications events because of coelution of PS 80-related peaks with peaks of interest.
期刊介绍:
The Journal of Chromatographic Science is devoted to the dissemination of information concerning all methods of chromatographic analysis. The standard manuscript is a description of recent original research that covers any or all phases of a specific separation problem, principle, or method. Manuscripts which have a high degree of novelty and fundamental significance to the field of separation science are particularly encouraged. It is expected the authors will clearly state in the Introduction how their method compares in some markedly new and improved way to previous published related methods. Analytical performance characteristics of new methods including sensitivity, tested limits of detection or quantification, accuracy, precision, and specificity should be provided. Manuscripts which describe a straightforward extension of a known analytical method or an application to a previously analyzed and/or uncomplicated sample matrix will not normally be reviewed favorably. Manuscripts in which mass spectrometry is the dominant analytical method and chromatography is of marked secondary importance may be declined.