Cindy Levesque-Boissonneault, Nicholas Bussière, Frédérique Roy-Côté, Frank Cloutier, Marie-Ève Caty, Johannes Frasnelli
{"title":"在家进行嗅觉和味觉功能障碍客观化快速测试:验证化学感知测试的概念证明。","authors":"Cindy Levesque-Boissonneault, Nicholas Bussière, Frédérique Roy-Côté, Frank Cloutier, Marie-Ève Caty, Johannes Frasnelli","doi":"10.1093/chemse/bjad033","DOIUrl":null,"url":null,"abstract":"<p><p>Recent studies have shown the efficacy of a home test for the self-evaluation of olfactory and gustatory functions in quarantined coronavirus disease-2019 (COVID-19) patients. However, testing was often limited to COVID-19 participants, and the accuracy of home test kits was rarely compared to standardized testing. This study aims at providing proof of concept for the validation of the new Chemosensory Perception Test (CPT) developed to remotely assess orthonasal olfactory, retronasal olfactory, and gustatory functions in various populations using common North American household items. In the 2 experiments, a total of 121 participants irrespective of having olfactory and/or gustatory complaints from various causes (COVID-19, sinunasal, post-viral, idiopathic) were tested first, with one or many of the following tests: (i) a brief chemosensory questionnaire, (ii) an olfactory test-Sniffin' Sticks Test (SST) or University of Pennsylvania Smell Identification Test (UPSIT), and/or (iii) a gustatory test-Brief Waterless Empirical Taste Test (B-WETT). We then applied the CPT which yielded 3 different subscores, namely orthonasal, retronasal, and gustatory CPT scores. The orthonasal CPT score was significantly correlated with SST (ρ = 0.837, P < 0.001) and UPSIT (ρ = 0.364, P < 0.001) scores, and exhibited an excellent accuracy to identify olfactory dysfunction (OD) as compared to SST (area under the curve [AUC]: 0.923 [95% confidence interval {CI}, 0.822-1.000], P < 0.001). The retronasal CPT score but not the gustatory CPT score allowed to distinguish between participants with or without subjective gustatory complaint (AUC: 0.818 [95% CI, 0.726-0.909], P < 0.001). The CPT has the ability to identify OD and to quantify subjective gustatory complaints.</p>","PeriodicalId":9771,"journal":{"name":"Chemical Senses","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10746307/pdf/","citationCount":"0","resultStr":"{\"title\":\"A quick test to objectify smell and taste dysfunction at home: a proof of concept for the validation of the chemosensory perception test.\",\"authors\":\"Cindy Levesque-Boissonneault, Nicholas Bussière, Frédérique Roy-Côté, Frank Cloutier, Marie-Ève Caty, Johannes Frasnelli\",\"doi\":\"10.1093/chemse/bjad033\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Recent studies have shown the efficacy of a home test for the self-evaluation of olfactory and gustatory functions in quarantined coronavirus disease-2019 (COVID-19) patients. However, testing was often limited to COVID-19 participants, and the accuracy of home test kits was rarely compared to standardized testing. This study aims at providing proof of concept for the validation of the new Chemosensory Perception Test (CPT) developed to remotely assess orthonasal olfactory, retronasal olfactory, and gustatory functions in various populations using common North American household items. In the 2 experiments, a total of 121 participants irrespective of having olfactory and/or gustatory complaints from various causes (COVID-19, sinunasal, post-viral, idiopathic) were tested first, with one or many of the following tests: (i) a brief chemosensory questionnaire, (ii) an olfactory test-Sniffin' Sticks Test (SST) or University of Pennsylvania Smell Identification Test (UPSIT), and/or (iii) a gustatory test-Brief Waterless Empirical Taste Test (B-WETT). We then applied the CPT which yielded 3 different subscores, namely orthonasal, retronasal, and gustatory CPT scores. The orthonasal CPT score was significantly correlated with SST (ρ = 0.837, P < 0.001) and UPSIT (ρ = 0.364, P < 0.001) scores, and exhibited an excellent accuracy to identify olfactory dysfunction (OD) as compared to SST (area under the curve [AUC]: 0.923 [95% confidence interval {CI}, 0.822-1.000], P < 0.001). The retronasal CPT score but not the gustatory CPT score allowed to distinguish between participants with or without subjective gustatory complaint (AUC: 0.818 [95% CI, 0.726-0.909], P < 0.001). The CPT has the ability to identify OD and to quantify subjective gustatory complaints.</p>\",\"PeriodicalId\":9771,\"journal\":{\"name\":\"Chemical Senses\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10746307/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chemical Senses\",\"FirstCategoryId\":\"102\",\"ListUrlMain\":\"https://doi.org/10.1093/chemse/bjad033\",\"RegionNum\":4,\"RegionCategory\":\"心理学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BEHAVIORAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemical Senses","FirstCategoryId":"102","ListUrlMain":"https://doi.org/10.1093/chemse/bjad033","RegionNum":4,"RegionCategory":"心理学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BEHAVIORAL SCIENCES","Score":null,"Total":0}
A quick test to objectify smell and taste dysfunction at home: a proof of concept for the validation of the chemosensory perception test.
Recent studies have shown the efficacy of a home test for the self-evaluation of olfactory and gustatory functions in quarantined coronavirus disease-2019 (COVID-19) patients. However, testing was often limited to COVID-19 participants, and the accuracy of home test kits was rarely compared to standardized testing. This study aims at providing proof of concept for the validation of the new Chemosensory Perception Test (CPT) developed to remotely assess orthonasal olfactory, retronasal olfactory, and gustatory functions in various populations using common North American household items. In the 2 experiments, a total of 121 participants irrespective of having olfactory and/or gustatory complaints from various causes (COVID-19, sinunasal, post-viral, idiopathic) were tested first, with one or many of the following tests: (i) a brief chemosensory questionnaire, (ii) an olfactory test-Sniffin' Sticks Test (SST) or University of Pennsylvania Smell Identification Test (UPSIT), and/or (iii) a gustatory test-Brief Waterless Empirical Taste Test (B-WETT). We then applied the CPT which yielded 3 different subscores, namely orthonasal, retronasal, and gustatory CPT scores. The orthonasal CPT score was significantly correlated with SST (ρ = 0.837, P < 0.001) and UPSIT (ρ = 0.364, P < 0.001) scores, and exhibited an excellent accuracy to identify olfactory dysfunction (OD) as compared to SST (area under the curve [AUC]: 0.923 [95% confidence interval {CI}, 0.822-1.000], P < 0.001). The retronasal CPT score but not the gustatory CPT score allowed to distinguish between participants with or without subjective gustatory complaint (AUC: 0.818 [95% CI, 0.726-0.909], P < 0.001). The CPT has the ability to identify OD and to quantify subjective gustatory complaints.
期刊介绍:
Chemical Senses publishes original research and review papers on all aspects of chemoreception in both humans and animals. An important part of the journal''s coverage is devoted to techniques and the development and application of new methods for investigating chemoreception and chemosensory structures.