{"title":"唾液饱和的吐痰罩会影响通风吗?","authors":"Mark W Kroll, Stacey L Hail, Michael A Brave","doi":"10.1097/PAF.0000000000000877","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>Spit hoods are used by law enforcement, officers in correctional facilities, and medical personnel during the restraint of agitated subjects that are actively spitting to prevent the transmission of droplet-transmitted pathogens. We could find no studies reporting on the time course of normal breathing to clear saliva from such a saturated spit hood. We purchased samples of 3 popular spit hood models and applied a section over the output of a pneumatic test system. We used a digital anemometer, digital manometer, and an inline controllable fan for back pressure and flow. The pressure was 3 mm Hg to match quiet breathing. The tested area was saturated with artificial saliva, and air pressure was applied while we recorded the pressure and airflow. Within 5 seconds, the spit hoods all cleared sufficient artificial saliva to allow 1 m/s of airflow, which exceeds that of an N95 mask with similar pressure. Commonly used spit hoods offer very low resistance to breathing even after being initially saturated with artificial saliva. Our results do not support the hypothesis that a saliva-filled spit hood might contribute to death.</p>","PeriodicalId":55535,"journal":{"name":"American Journal of Forensic Medicine and Pathology","volume":" ","pages":"10-14"},"PeriodicalIF":1.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Do Saliva-Saturated Spit Hoods Interfere With Ventilation?\",\"authors\":\"Mark W Kroll, Stacey L Hail, Michael A Brave\",\"doi\":\"10.1097/PAF.0000000000000877\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Abstract: </strong>Spit hoods are used by law enforcement, officers in correctional facilities, and medical personnel during the restraint of agitated subjects that are actively spitting to prevent the transmission of droplet-transmitted pathogens. We could find no studies reporting on the time course of normal breathing to clear saliva from such a saturated spit hood. We purchased samples of 3 popular spit hood models and applied a section over the output of a pneumatic test system. We used a digital anemometer, digital manometer, and an inline controllable fan for back pressure and flow. The pressure was 3 mm Hg to match quiet breathing. The tested area was saturated with artificial saliva, and air pressure was applied while we recorded the pressure and airflow. Within 5 seconds, the spit hoods all cleared sufficient artificial saliva to allow 1 m/s of airflow, which exceeds that of an N95 mask with similar pressure. Commonly used spit hoods offer very low resistance to breathing even after being initially saturated with artificial saliva. Our results do not support the hypothesis that a saliva-filled spit hood might contribute to death.</p>\",\"PeriodicalId\":55535,\"journal\":{\"name\":\"American Journal of Forensic Medicine and Pathology\",\"volume\":\" \",\"pages\":\"10-14\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American Journal of Forensic Medicine and Pathology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/PAF.0000000000000877\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/8/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, LEGAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Forensic Medicine and Pathology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/PAF.0000000000000877","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/14 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"MEDICINE, LEGAL","Score":null,"Total":0}
Do Saliva-Saturated Spit Hoods Interfere With Ventilation?
Abstract: Spit hoods are used by law enforcement, officers in correctional facilities, and medical personnel during the restraint of agitated subjects that are actively spitting to prevent the transmission of droplet-transmitted pathogens. We could find no studies reporting on the time course of normal breathing to clear saliva from such a saturated spit hood. We purchased samples of 3 popular spit hood models and applied a section over the output of a pneumatic test system. We used a digital anemometer, digital manometer, and an inline controllable fan for back pressure and flow. The pressure was 3 mm Hg to match quiet breathing. The tested area was saturated with artificial saliva, and air pressure was applied while we recorded the pressure and airflow. Within 5 seconds, the spit hoods all cleared sufficient artificial saliva to allow 1 m/s of airflow, which exceeds that of an N95 mask with similar pressure. Commonly used spit hoods offer very low resistance to breathing even after being initially saturated with artificial saliva. Our results do not support the hypothesis that a saliva-filled spit hood might contribute to death.
期刊介绍:
Drawing on the expertise of leading forensic pathologists, lawyers, and criminologists, The American Journal of Forensic Medicine and Pathology presents up-to-date coverage of forensic medical practices worldwide. Each issue of the journal features original articles on new examination and documentation procedures.
While most articles are available as web based articles, PDF and in ePub reader format, some earlier articles do not have PDFs available. If you would like to view an article in the ePub format, you will need to download an ePub reader to view this file, a number of which are available for free online.