T恤测试用于评估无支撑坐在手动轮椅使用者脊髓损伤的可靠性和有效性。

IF 1.5 4区 医学 Q3 REHABILITATION
Francielle Romanini, Rafaella M Zambetta, Natália Padula, Roberta C Gaspar, Thiago L Russo, Jocemar Ilha
{"title":"T恤测试用于评估无支撑坐在手动轮椅使用者脊髓损伤的可靠性和有效性。","authors":"Francielle Romanini,&nbsp;Rafaella M Zambetta,&nbsp;Natália Padula,&nbsp;Roberta C Gaspar,&nbsp;Thiago L Russo,&nbsp;Jocemar Ilha","doi":"10.1097/MRR.0000000000000600","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to evaluate the validity and reliability of the T-shirt test (TST) in assessing sitting stability under three thigh support conditions and with timed outcomes derived in six ways among individuals with a spinal cord injury (SCI). The TST was performed five times under three thigh support conditions (85%, 55% and 25% of total thigh length) in two evaluations spaced between 7-14 days. For each thigh condition, six different outcomes were derived (average or best time from 2, 3, and 5 trial). All outcomes derivation showed excellent reliability on test day (intraclass correlation coefficient; ICC  ≥ 0.997) and excellent test-retest reliability (ICC ≥ 0.874) for each thigh support condition. The TST showed high inverse correlations with the Spinal Cord Independence Measure III (SCIM)-mobility score for all outcomes and support conditions (ρ≥-0.706), except for Best-5; moderate inverse correlations with total SCIM-total scores for most outcome derivations and support conditions (ρ≥-0.636); and a moderate inverse correlation with confidence and capacity domains of Wheelchair Skills Test-Questionnaire for most outcome derivation and support conditions (ρ≥-0.504). The TST could discriminate cervical from high and low thoracic levels of injuries under minimal thigh support condition. Overall, all the TST-derived outcomes and support conditions showed adequate validity and test-retest reliability, but Best-5 had inconsistency. Under the minimal thigh support condition, all outcome derivations except Best-3 could discriminate cervical from other injury-level groups. Although all outcome derivations and thigh support conditions provided reliable results, we recommend using the average of 3 trials under the maximal thigh support condition.</p>","PeriodicalId":14301,"journal":{"name":"International Journal of Rehabilitation Research","volume":" ","pages":"331-337"},"PeriodicalIF":1.5000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reliability and validity of the T-shirt test for the assessment of unsupported sitting in manual wheelchair users with spinal cord injury.\",\"authors\":\"Francielle Romanini,&nbsp;Rafaella M Zambetta,&nbsp;Natália Padula,&nbsp;Roberta C Gaspar,&nbsp;Thiago L Russo,&nbsp;Jocemar Ilha\",\"doi\":\"10.1097/MRR.0000000000000600\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study aimed to evaluate the validity and reliability of the T-shirt test (TST) in assessing sitting stability under three thigh support conditions and with timed outcomes derived in six ways among individuals with a spinal cord injury (SCI). The TST was performed five times under three thigh support conditions (85%, 55% and 25% of total thigh length) in two evaluations spaced between 7-14 days. For each thigh condition, six different outcomes were derived (average or best time from 2, 3, and 5 trial). All outcomes derivation showed excellent reliability on test day (intraclass correlation coefficient; ICC  ≥ 0.997) and excellent test-retest reliability (ICC ≥ 0.874) for each thigh support condition. The TST showed high inverse correlations with the Spinal Cord Independence Measure III (SCIM)-mobility score for all outcomes and support conditions (ρ≥-0.706), except for Best-5; moderate inverse correlations with total SCIM-total scores for most outcome derivations and support conditions (ρ≥-0.636); and a moderate inverse correlation with confidence and capacity domains of Wheelchair Skills Test-Questionnaire for most outcome derivation and support conditions (ρ≥-0.504). The TST could discriminate cervical from high and low thoracic levels of injuries under minimal thigh support condition. Overall, all the TST-derived outcomes and support conditions showed adequate validity and test-retest reliability, but Best-5 had inconsistency. Under the minimal thigh support condition, all outcome derivations except Best-3 could discriminate cervical from other injury-level groups. Although all outcome derivations and thigh support conditions provided reliable results, we recommend using the average of 3 trials under the maximal thigh support condition.</p>\",\"PeriodicalId\":14301,\"journal\":{\"name\":\"International Journal of Rehabilitation Research\",\"volume\":\" \",\"pages\":\"331-337\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Rehabilitation Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/MRR.0000000000000600\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/8/15 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"REHABILITATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Rehabilitation Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MRR.0000000000000600","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/15 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在评估T恤测试(TST)在评估三种大腿支撑条件下的坐姿稳定性方面的有效性和可靠性,并通过六种方式得出脊髓损伤(SCI)患者的时间结果。在间隔7-14天的两次评估中,在三种大腿支撑条件下(占大腿总长度的85%、55%和25%)进行了五次TST。对于每种大腿状况,得出六种不同的结果(2、3和5次试验的平均或最佳时间)。所有结果推导在测试日显示出良好的可靠性(组内相关系数;ICC ≥ 0.997)和良好的重测可靠性(ICC ≥ 0.874)。除Best-5外,TST与所有结果和支持条件下的脊髓独立性测量III(SCIM)-活动性评分呈高度负相关(ρ≥-0.706);在大多数结果推导和支持条件下,与SCIM总分呈中度负相关(ρ≥-0.636);在大多数结果推导和支持条件下,与轮椅技能测试问卷的置信度和能力域呈中度负相关(ρ≥-0.504)。TST可以在最小大腿支持条件下区分颈部和胸部的损伤程度。总体而言,所有TST得出的结果和支持条件都显示出足够的有效性和重新测试的可靠性,但Best-5存在不一致性。在最小大腿支撑条件下,除Best-3外的所有结果推导都可以区分宫颈损伤和其他损伤水平组。尽管所有结果推导和大腿支撑条件都提供了可靠的结果,但我们建议在最大大腿支撑条件下使用3次试验的平均值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reliability and validity of the T-shirt test for the assessment of unsupported sitting in manual wheelchair users with spinal cord injury.

This study aimed to evaluate the validity and reliability of the T-shirt test (TST) in assessing sitting stability under three thigh support conditions and with timed outcomes derived in six ways among individuals with a spinal cord injury (SCI). The TST was performed five times under three thigh support conditions (85%, 55% and 25% of total thigh length) in two evaluations spaced between 7-14 days. For each thigh condition, six different outcomes were derived (average or best time from 2, 3, and 5 trial). All outcomes derivation showed excellent reliability on test day (intraclass correlation coefficient; ICC  ≥ 0.997) and excellent test-retest reliability (ICC ≥ 0.874) for each thigh support condition. The TST showed high inverse correlations with the Spinal Cord Independence Measure III (SCIM)-mobility score for all outcomes and support conditions (ρ≥-0.706), except for Best-5; moderate inverse correlations with total SCIM-total scores for most outcome derivations and support conditions (ρ≥-0.636); and a moderate inverse correlation with confidence and capacity domains of Wheelchair Skills Test-Questionnaire for most outcome derivation and support conditions (ρ≥-0.504). The TST could discriminate cervical from high and low thoracic levels of injuries under minimal thigh support condition. Overall, all the TST-derived outcomes and support conditions showed adequate validity and test-retest reliability, but Best-5 had inconsistency. Under the minimal thigh support condition, all outcome derivations except Best-3 could discriminate cervical from other injury-level groups. Although all outcome derivations and thigh support conditions provided reliable results, we recommend using the average of 3 trials under the maximal thigh support condition.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.10
自引率
0.00%
发文量
88
审稿时长
6-12 weeks
期刊介绍: International Journal of Rehabilitation Research is a quarterly, peer-reviewed, interdisciplinary forum for the publication of research into functioning, disability and contextual factors experienced by persons of all ages in both developed and developing societies. The wealth of information offered makes the journal a valuable resource for researchers, practitioners, and administrators in such fields as rehabilitation medicine, outcome measurement nursing, social and vocational rehabilitation/case management, return to work, special education, social policy, social work and social welfare, sociology, psychology, psychiatry assistive technology and environmental factors/disability. Areas of interest include functioning and disablement throughout the life cycle; rehabilitation programmes for persons with physical, sensory, mental and developmental disabilities; measurement of functioning and disability; special education and vocational rehabilitation; equipment access and transportation; information technology; independent living; consumer, legal, economic and sociopolitical aspects of functioning, disability and contextual factors.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信