Rate of saphenous vein occlusion and side effects at 1 year follow up after 1470 nm endolaser.

IF 0.8 Q4 PERIPHERAL VASCULAR DISEASE
Leonardo Zelotti Movio, Marco Antônio Forastieri Mansano, Marcelo Eckert Zanoni, Nancy Christiane Ferreira Silva, Marcel Pereira Rangel
{"title":"Rate of saphenous vein occlusion and side effects at 1 year follow up after 1470 nm endolaser.","authors":"Leonardo Zelotti Movio,&nbsp;Marco Antônio Forastieri Mansano,&nbsp;Marcelo Eckert Zanoni,&nbsp;Nancy Christiane Ferreira Silva,&nbsp;Marcel Pereira Rangel","doi":"10.1590/1677-5449.202101812","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Use of endolaser for chronic venous disease involves choosing the laser wavelength and optical fiber to use and the quantity of energy to be administered. Efficacy is assessed by the venous occlusion rate and safety is evaluated in terms of side effects.</p><p><strong>Objectives: </strong>To determine the incidence of total post-endolaser saphenous vein occlusion at 1-year follow-up. To describe side effects and their incidence and rates of reintervention or supplementary treatment during the postoperative period.</p><p><strong>Methods: </strong>A retrospective, observational cohort study with a quantitative approach, enrolling patients with saphenous vein incompetence treated with intravenous 1,470 nm laser ablation. Data were input to an MS Excel 2019 spreadsheet, calculating means and standard deviations with the software's Power Query supplement.</p><p><strong>Results: </strong>38 patients and 104 venous segments were eligible for the study. 100% were occluded at 30 days and 99.04% were still occluded at 1 year after the procedure. Mean Linear Endovenous Energy Density administered to the internal saphenous vein was 2,040.52 W/cm/s with standard deviation of ± 1,510.06 W/cm/s and 1,168.4 W/cm/s with standard deviation of ± 665.011 W/cm/s was administered to the external saphenous vein. Pain along the saphenous path was the most common side effect, with eight cases (21.05%), followed by one case of paresthesia (2.63%).</p><p><strong>Conclusions: </strong>The total occlusion rate at 1-year follow-up suggests the technique is promising and is currently applicable in this sample. The incidence of pain and paresthesia may be caused by the high mean energy delivered in some cases. It is recommended that multicenter studies be conducted with larger and more uniform samples in terms of their Clinical-Etiological-Anatomical-Pathological classifications.</p>","PeriodicalId":14814,"journal":{"name":"Jornal Vascular Brasileiro","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10421577/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jornal Vascular Brasileiro","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/1677-5449.202101812","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Use of endolaser for chronic venous disease involves choosing the laser wavelength and optical fiber to use and the quantity of energy to be administered. Efficacy is assessed by the venous occlusion rate and safety is evaluated in terms of side effects.

Objectives: To determine the incidence of total post-endolaser saphenous vein occlusion at 1-year follow-up. To describe side effects and their incidence and rates of reintervention or supplementary treatment during the postoperative period.

Methods: A retrospective, observational cohort study with a quantitative approach, enrolling patients with saphenous vein incompetence treated with intravenous 1,470 nm laser ablation. Data were input to an MS Excel 2019 spreadsheet, calculating means and standard deviations with the software's Power Query supplement.

Results: 38 patients and 104 venous segments were eligible for the study. 100% were occluded at 30 days and 99.04% were still occluded at 1 year after the procedure. Mean Linear Endovenous Energy Density administered to the internal saphenous vein was 2,040.52 W/cm/s with standard deviation of ± 1,510.06 W/cm/s and 1,168.4 W/cm/s with standard deviation of ± 665.011 W/cm/s was administered to the external saphenous vein. Pain along the saphenous path was the most common side effect, with eight cases (21.05%), followed by one case of paresthesia (2.63%).

Conclusions: The total occlusion rate at 1-year follow-up suggests the technique is promising and is currently applicable in this sample. The incidence of pain and paresthesia may be caused by the high mean energy delivered in some cases. It is recommended that multicenter studies be conducted with larger and more uniform samples in terms of their Clinical-Etiological-Anatomical-Pathological classifications.

Abstract Image

Abstract Image

1470 nm激光术后1年随访隐静脉闭塞率及不良反应。
背景:使用内激光治疗慢性静脉疾病涉及到选择激光波长和光纤的使用以及给药能量的数量。通过静脉闭塞率来评估疗效,通过副作用来评估安全性。目的:观察激光手术后隐静脉闭塞1年的发生率。目的:描述术后不良反应及其发生率、再干预或补充治疗率。方法:采用回顾性、观察性队列研究,采用定量方法,纳入静脉内1470 nm激光消融治疗的隐静脉功能不全患者。数据输入到MS Excel 2019电子表格中,使用软件的Power Query补充计算平均值和标准差。结果:38例患者和104个静脉段符合研究条件。术后30天100%闭塞,术后1年仍有99.04%闭塞。内隐静脉平均线性静脉内能量密度为2040.52 W/cm/s,标准差为±1510.06 W/cm/s;外隐静脉平均线性静脉内能量密度为1168.4 W/cm/s,标准差为±665.011 W/cm/s。沿隐静脉路径疼痛是最常见的副作用,有8例(21.05%),其次是1例感觉异常(2.63%)。结论:1年随访的总闭塞率表明该技术是有希望的,目前适用于该样本。在某些情况下,疼痛和感觉异常的发生可能是由高平均能量传递引起的。根据临床-病因-解剖-病理分类,建议采用更大、更统一的样本进行多中心研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Jornal Vascular Brasileiro
Jornal Vascular Brasileiro Medicine-Cardiology and Cardiovascular Medicine
CiteScore
1.20
自引率
0.00%
发文量
57
审稿时长
20 weeks
期刊介绍: The Jornal Vascular Brasileiro is editated and published quaterly to select and disseminate high-quality scientific contents concerning original research, novel surgical and diagnostic techniques, and clinical observations in the field of vascular surgery, angiology, and endovascular surgery. Its abbreviated title is J. Vasc. Bras., which should be used in bibliographies, footnotes and bibliographical references and strips.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信