{"title":"Comparison of 980-nm/1470-nm Dual-Wavelength Fiber Laser Versus Ultrasonic Scalpel Device in Open Thyroidectomy.","authors":"Faya Liang, Peiliang Lin, Ping Han, Xijun Lin, Renhui Chen, Jingyi Wang, Lanlan Deng, Xin Zou, Tan Cheng, Xiaoming Huang","doi":"10.1089/photob.2023.0022","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Background:</i></b> To investigate the application value of 980-nm/1470-nm dual-wavelength fiber laser in thyroidectomy. <b><i>Methods:</i></b> The clinical data of 130 patients undergoing thyroid surgery from March 2017 to December 2018 were retrospectively analyzed. According to the use types of energy devices, the patients were divided into laser group and ultrasonic scalpel group, with 65 patients in each group. The baseline data, operation-related indicators, operation complications, postoperative pathological conditions, and follow-up results of the two groups were compared. <b><i>Results:</i></b> The operations were successfully completed in both groups. The median operative time of total thyroidectomy (TT), lobectomy+central lymph node dissection (CLND), TT+CLND in the laser group were longer than that in the harmonic scalpel group, and the difference was statistically significant (<i>p</i> < 0.05). The incidence of parathyroid gland congestion in the laser group (10.3%) was lower than that in the harmonic scalpel group (19.2%), and the difference was statistically significant (<i>p</i> < 0.05). No significant differences were found in operative type, intraoperative blood loss, postoperative drainage volume, operative complications, postoperative hospital stay, and lymph node metastasis rate between the two groups (<i>p</i> > 0.05). No incidence was noted of recurrence, metastasis, or death in both groups. <b><i>Conclusions:</i></b> The 980-nm/1470-nm dual-wavelength fiber laser had an efficacy in open thyroidectomy similar to that of the harmonic scalpel, was safe and feasible, and less damage to the parathyroid gland blood supply than a scalpel. It can be used as a new option for thyroid surgery.</p>","PeriodicalId":20111,"journal":{"name":"Photobiomodulation, photomedicine, and laser surgery","volume":"41 8","pages":"422-428"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Photobiomodulation, photomedicine, and laser surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1089/photob.2023.0022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: To investigate the application value of 980-nm/1470-nm dual-wavelength fiber laser in thyroidectomy. Methods: The clinical data of 130 patients undergoing thyroid surgery from March 2017 to December 2018 were retrospectively analyzed. According to the use types of energy devices, the patients were divided into laser group and ultrasonic scalpel group, with 65 patients in each group. The baseline data, operation-related indicators, operation complications, postoperative pathological conditions, and follow-up results of the two groups were compared. Results: The operations were successfully completed in both groups. The median operative time of total thyroidectomy (TT), lobectomy+central lymph node dissection (CLND), TT+CLND in the laser group were longer than that in the harmonic scalpel group, and the difference was statistically significant (p < 0.05). The incidence of parathyroid gland congestion in the laser group (10.3%) was lower than that in the harmonic scalpel group (19.2%), and the difference was statistically significant (p < 0.05). No significant differences were found in operative type, intraoperative blood loss, postoperative drainage volume, operative complications, postoperative hospital stay, and lymph node metastasis rate between the two groups (p > 0.05). No incidence was noted of recurrence, metastasis, or death in both groups. Conclusions: The 980-nm/1470-nm dual-wavelength fiber laser had an efficacy in open thyroidectomy similar to that of the harmonic scalpel, was safe and feasible, and less damage to the parathyroid gland blood supply than a scalpel. It can be used as a new option for thyroid surgery.
背景:探讨980 nm/1470 nm双波长光纤激光器在甲状腺切除术中的应用价值。方法:回顾性分析2017年3月至2018年12月130例甲状腺手术患者的临床资料。根据能量装置的使用类型,将患者分为激光组和超声手术刀组,每组65例。比较两组患者的基线资料、手术相关指标、手术并发症、术后病理情况及随访结果。结果:两组患者均顺利完成手术。激光组甲状腺全切除术(TT)、肺叶切除术+中央淋巴结清扫术(CLND)、TT+CLND的中位手术时间均长于谐波刀组,差异有统计学意义(p p p > 0.05)。两组患者均未发生复发、转移或死亡。结论:980 nm/1470 nm双波长光纤激光在开放式甲状腺切除术中的疗效与谐波刀相当,安全可行,且对甲状旁腺血液供应的损害小于手术刀。它可以作为甲状腺手术的新选择。