Comparison of 980-nm/1470-nm Dual-Wavelength Fiber Laser Versus Ultrasonic Scalpel Device in Open Thyroidectomy.

Faya Liang, Peiliang Lin, Ping Han, Xijun Lin, Renhui Chen, Jingyi Wang, Lanlan Deng, Xin Zou, Tan Cheng, Xiaoming Huang
{"title":"Comparison of 980-nm/1470-nm Dual-Wavelength Fiber Laser Versus Ultrasonic Scalpel Device in Open Thyroidectomy.","authors":"Faya Liang,&nbsp;Peiliang Lin,&nbsp;Ping Han,&nbsp;Xijun Lin,&nbsp;Renhui Chen,&nbsp;Jingyi Wang,&nbsp;Lanlan Deng,&nbsp;Xin Zou,&nbsp;Tan Cheng,&nbsp;Xiaoming Huang","doi":"10.1089/photob.2023.0022","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Background:</i></b> To investigate the application value of 980-nm/1470-nm dual-wavelength fiber laser in thyroidectomy. <b><i>Methods:</i></b> The clinical data of 130 patients undergoing thyroid surgery from March 2017 to December 2018 were retrospectively analyzed. According to the use types of energy devices, the patients were divided into laser group and ultrasonic scalpel group, with 65 patients in each group. The baseline data, operation-related indicators, operation complications, postoperative pathological conditions, and follow-up results of the two groups were compared. <b><i>Results:</i></b> The operations were successfully completed in both groups. The median operative time of total thyroidectomy (TT), lobectomy+central lymph node dissection (CLND), TT+CLND in the laser group were longer than that in the harmonic scalpel group, and the difference was statistically significant (<i>p</i> < 0.05). The incidence of parathyroid gland congestion in the laser group (10.3%) was lower than that in the harmonic scalpel group (19.2%), and the difference was statistically significant (<i>p</i> < 0.05). No significant differences were found in operative type, intraoperative blood loss, postoperative drainage volume, operative complications, postoperative hospital stay, and lymph node metastasis rate between the two groups (<i>p</i> > 0.05). No incidence was noted of recurrence, metastasis, or death in both groups. <b><i>Conclusions:</i></b> The 980-nm/1470-nm dual-wavelength fiber laser had an efficacy in open thyroidectomy similar to that of the harmonic scalpel, was safe and feasible, and less damage to the parathyroid gland blood supply than a scalpel. It can be used as a new option for thyroid surgery.</p>","PeriodicalId":20111,"journal":{"name":"Photobiomodulation, photomedicine, and laser surgery","volume":"41 8","pages":"422-428"},"PeriodicalIF":0.0000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Photobiomodulation, photomedicine, and laser surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1089/photob.2023.0022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: To investigate the application value of 980-nm/1470-nm dual-wavelength fiber laser in thyroidectomy. Methods: The clinical data of 130 patients undergoing thyroid surgery from March 2017 to December 2018 were retrospectively analyzed. According to the use types of energy devices, the patients were divided into laser group and ultrasonic scalpel group, with 65 patients in each group. The baseline data, operation-related indicators, operation complications, postoperative pathological conditions, and follow-up results of the two groups were compared. Results: The operations were successfully completed in both groups. The median operative time of total thyroidectomy (TT), lobectomy+central lymph node dissection (CLND), TT+CLND in the laser group were longer than that in the harmonic scalpel group, and the difference was statistically significant (p < 0.05). The incidence of parathyroid gland congestion in the laser group (10.3%) was lower than that in the harmonic scalpel group (19.2%), and the difference was statistically significant (p < 0.05). No significant differences were found in operative type, intraoperative blood loss, postoperative drainage volume, operative complications, postoperative hospital stay, and lymph node metastasis rate between the two groups (p > 0.05). No incidence was noted of recurrence, metastasis, or death in both groups. Conclusions: The 980-nm/1470-nm dual-wavelength fiber laser had an efficacy in open thyroidectomy similar to that of the harmonic scalpel, was safe and feasible, and less damage to the parathyroid gland blood supply than a scalpel. It can be used as a new option for thyroid surgery.

980 nm/1470 nm双波长光纤激光与超声手术刀在开放性甲状腺切除术中的比较。
背景:探讨980 nm/1470 nm双波长光纤激光器在甲状腺切除术中的应用价值。方法:回顾性分析2017年3月至2018年12月130例甲状腺手术患者的临床资料。根据能量装置的使用类型,将患者分为激光组和超声手术刀组,每组65例。比较两组患者的基线资料、手术相关指标、手术并发症、术后病理情况及随访结果。结果:两组患者均顺利完成手术。激光组甲状腺全切除术(TT)、肺叶切除术+中央淋巴结清扫术(CLND)、TT+CLND的中位手术时间均长于谐波刀组,差异有统计学意义(p p p > 0.05)。两组患者均未发生复发、转移或死亡。结论:980 nm/1470 nm双波长光纤激光在开放式甲状腺切除术中的疗效与谐波刀相当,安全可行,且对甲状旁腺血液供应的损害小于手术刀。它可以作为甲状腺手术的新选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信