{"title":"A comparison of endovascular coil systems for the treatment of small intracranial aneurysms.","authors":"Sabrina L Begley, Timothy G White, Kevin A Shah, Justin Turpin, Daniel Toscano, Amir R Dehdashti, Ina Teron, Thomas Link, Athos Patsalides, Henry H Woo","doi":"10.1177/15910199231182456","DOIUrl":null,"url":null,"abstract":"<p><p>BackgroundEndovascular coiling of small, intracranial aneurysms remains controversial and difficult, despite advances in technology.MethodsWe retrospectively reviewed data for 62 small aneurysms (<3.99 mm) in 59 patients. Occlusion rates, complications rates, and coil packing densities were compared between subgroups based upon coil type and rupture status.ResultsRuptured aneurysms predominated (67.7%). Aneurysms measured 2.99 ± 0.63 mm by 2.51 ± 0.61 mm with an aspect ratio of 1.21 ± 0.34 mm. Brands included Optima (Balt) (29%), MicroVention Hydrogel (24.2%), and Penumbra SMART (19.4%) coil systems. Average packing density was 34.3 ± 13.5 mm<sup>3</sup>. Occlusion rate was 100% in unruptured aneurysms; 84% utilized adjuvant devices. For ruptured aneurysms, complete occlusion or stable neck remnant was achieved in 88.6% while recanalization occurred in 11.4%. No rebleeding occurred. Average packing density (<i>p</i> = 0.919) and coil type (<i>p</i> = 0.056) did not impact occlusion. Aspect ratio was smaller in aneurysms with technical complications (<i>p</i> = 0.281), and aneurysm volume was significantly smaller in those with coil protrusion (<i>p</i> = 0.018). Complication rates did not differ between ruptured and unruptured aneurysms (22.6 vs. 15.8%, <i>p</i> = 0.308) or coil types (<i>p</i> = 0.830).ConclusionDespite advances in embolization devices, coiling of small intracranial aneurysms is still scrutinized. High occlusion rates are achievable, especially in unruptured aneurysms, with coil type and packing density suggesting association with complete occlusion. Technical complications may be influenced by aneurysm geometry. Advances in endovascular technologies have revolutionized small aneurysm treatment, with this series demonstrating excellent aneurysm occlusion especially in unruptured aneurysms.</p>","PeriodicalId":14380,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"690-696"},"PeriodicalIF":2.1000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12475379/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199231182456","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/13 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

BackgroundEndovascular coiling of small, intracranial aneurysms remains controversial and difficult, despite advances in technology.MethodsWe retrospectively reviewed data for 62 small aneurysms (<3.99 mm) in 59 patients. Occlusion rates, complications rates, and coil packing densities were compared between subgroups based upon coil type and rupture status.ResultsRuptured aneurysms predominated (67.7%). Aneurysms measured 2.99 ± 0.63 mm by 2.51 ± 0.61 mm with an aspect ratio of 1.21 ± 0.34 mm. Brands included Optima (Balt) (29%), MicroVention Hydrogel (24.2%), and Penumbra SMART (19.4%) coil systems. Average packing density was 34.3 ± 13.5 mm3. Occlusion rate was 100% in unruptured aneurysms; 84% utilized adjuvant devices. For ruptured aneurysms, complete occlusion or stable neck remnant was achieved in 88.6% while recanalization occurred in 11.4%. No rebleeding occurred. Average packing density (p = 0.919) and coil type (p = 0.056) did not impact occlusion. Aspect ratio was smaller in aneurysms with technical complications (p = 0.281), and aneurysm volume was significantly smaller in those with coil protrusion (p = 0.018). Complication rates did not differ between ruptured and unruptured aneurysms (22.6 vs. 15.8%, p = 0.308) or coil types (p = 0.830).ConclusionDespite advances in embolization devices, coiling of small intracranial aneurysms is still scrutinized. High occlusion rates are achievable, especially in unruptured aneurysms, with coil type and packing density suggesting association with complete occlusion. Technical complications may be influenced by aneurysm geometry. Advances in endovascular technologies have revolutionized small aneurysm treatment, with this series demonstrating excellent aneurysm occlusion especially in unruptured aneurysms.

血管内线圈系统治疗颅内小动脉瘤的比较。
背景:尽管技术进步,颅内小动脉瘤的血管卷曲仍然存在争议和困难。方法回顾性分析62例小动脉瘤(3例)的临床资料。未破裂动脉瘤的闭塞率为100%;84%使用辅助器械。对于破裂的动脉瘤,88.6%的患者实现了完全闭塞或稳定的颈部残余,11.4%的患者实现了再通。无再出血发生。平均填充密度(p = 0.919)和线圈类型(p = 0.056)对闭塞无影响。有技术并发症的动脉瘤宽高比较小(p = 0.281),有线圈突出的动脉瘤体积较小(p = 0.018)。并发症发生率在破裂动脉瘤和未破裂动脉瘤(22.6 vs 15.8%, p = 0.308)或动脉瘤圈类型(p = 0.830)之间没有差异。结论尽管栓塞装置有了进步,颅内小动脉瘤的栓塞仍需仔细检查。高闭塞率是可以实现的,特别是在未破裂的动脉瘤中,线圈类型和填充密度提示与完全闭塞有关。技术性并发症可能受动脉瘤几何形状的影响。血管内技术的进步使小动脉瘤治疗发生了革命性的变化,这一系列的研究表明,在未破裂的动脉瘤中,动脉瘤的闭塞效果非常好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.80
自引率
11.80%
发文量
192
审稿时长
6-12 weeks
期刊介绍: Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信