{"title":"Current status of optical scanning in facial prosthetics: A systematic review and meta-analysis.","authors":"János König, Kata Kelemen, László Márk Czumbel, Bence Szabó, Gábor Varga, Judit Borbély, Orsolya Németh, Péter Hegyi, Péter Hermann","doi":"10.2186/jpr.JPR_D_22_00221","DOIUrl":null,"url":null,"abstract":"<p><p>Purpose To assess the accuracy of scanning technologies for constructing facial prostheses on human faces.Study selection Our systematic search was performed on five databases. Studies reporting on human volunteers (P) whose faces were scanned with a scanning technology were eligible. The anthropometrical interlandmark distances (ILDs) were used as indicators of accuracy; the ILDs are measured on the virtual models (I) and directly on the faces (C). The virtual models deviated from their true values (O). Studies reporting the measurements on patients with or without facial deformities were included, but cadavers or inanimate objects were reasons for exclusion. We performed a mean difference (MD) / standardized MD analysis with a random effect model. The difficulties regarding the scanning procedure mentioned in the articles were also assessed.Results We found 3723 records after duplicate removal. Twenty five articles were eligible for the qualitative review, and ten articles were included in the quantitative synthesis. Eight different ILDs were compared in MD analyses. The differences were between -0.54-0.43 mm. We also performed a regional three-dimensional analysis to compare scanning technologies in each major region. No significant differences were found in any of the regions and axes. The most mentioned difficulties were artifacts due to motion or blinking.Conclusions The results suggest no systematic skew in linear dimensions neither between direct caliper measurements nor between measurements on the scanned models, scanning technologies, or facial regions.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2186/jpr.JPR_D_22_00221","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/8 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose To assess the accuracy of scanning technologies for constructing facial prostheses on human faces.Study selection Our systematic search was performed on five databases. Studies reporting on human volunteers (P) whose faces were scanned with a scanning technology were eligible. The anthropometrical interlandmark distances (ILDs) were used as indicators of accuracy; the ILDs are measured on the virtual models (I) and directly on the faces (C). The virtual models deviated from their true values (O). Studies reporting the measurements on patients with or without facial deformities were included, but cadavers or inanimate objects were reasons for exclusion. We performed a mean difference (MD) / standardized MD analysis with a random effect model. The difficulties regarding the scanning procedure mentioned in the articles were also assessed.Results We found 3723 records after duplicate removal. Twenty five articles were eligible for the qualitative review, and ten articles were included in the quantitative synthesis. Eight different ILDs were compared in MD analyses. The differences were between -0.54-0.43 mm. We also performed a regional three-dimensional analysis to compare scanning technologies in each major region. No significant differences were found in any of the regions and axes. The most mentioned difficulties were artifacts due to motion or blinking.Conclusions The results suggest no systematic skew in linear dimensions neither between direct caliper measurements nor between measurements on the scanned models, scanning technologies, or facial regions.

光学扫描在面部修复中的应用现状:系统回顾和荟萃分析。
目的 评估在人脸上构建面部义齿的扫描技术的准确性。我们在五个数据库中进行了系统性搜索,符合条件的研究报告涉及使用扫描技术对人脸进行扫描的人类志愿者(P)。人体测量学上的地标间距离(ILD)被用作准确性的指标;ILD 是在虚拟模型(I)和直接在人脸(C)上测量的。虚拟模型偏离真实值(O)。报告对面部畸形或无面部畸形患者进行测量的研究也包括在内,但尸体或无生命物体是排除在外的原因。我们采用随机效应模型进行了平均差(MD)/标准化 MD 分析。我们还对文章中提到的扫描过程中的困难进行了评估。有 25 篇文章符合定性综述的条件,10 篇文章被纳入定量综述。在 MD 分析中对八种不同的 ILD 进行了比较。差异在-0.54-0.43毫米之间。我们还进行了区域三维分析,以比较各主要区域的扫描技术。没有发现任何区域和轴有明显差异。结论 结果表明,无论是在卡尺直接测量之间,还是在扫描模型、扫描技术或面部区域测量之间,线性尺寸都没有系统性偏差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信