K Bergin-Taylor, M P Funnell, R A Ferguson, S A Mears, L J James
{"title":"Serum osmolality measured in fingertip capillary blood is comparable to serum osmolality measured in venous blood.","authors":"K Bergin-Taylor, M P Funnell, R A Ferguson, S A Mears, L J James","doi":"10.1139/apnm-2022-0358","DOIUrl":null,"url":null,"abstract":"<p><p>Blood osmolality is considered the gold standard hydration assessment, but has limited application for technical and invasive reasons. Paired antecubital-venous blood and fingertip-capillary blood were collected pre- and 30 min post-drinking 600 mL water in 55 male/female participants. No bias (0.2 mOsmo/kg, limits of agreement = -2.5 to 2.8 mOsmo/kg) was found between sampling methods, with high linear correlation (Spearman's <i>r</i> = 0.95, <i>P</i> < 0.001). Capillary blood sampling offers an accurate less-invasive method for determining serum osmolality than venous blood sampling.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1139/apnm-2022-0358","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/8 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0
Abstract
Blood osmolality is considered the gold standard hydration assessment, but has limited application for technical and invasive reasons. Paired antecubital-venous blood and fingertip-capillary blood were collected pre- and 30 min post-drinking 600 mL water in 55 male/female participants. No bias (0.2 mOsmo/kg, limits of agreement = -2.5 to 2.8 mOsmo/kg) was found between sampling methods, with high linear correlation (Spearman's r = 0.95, P < 0.001). Capillary blood sampling offers an accurate less-invasive method for determining serum osmolality than venous blood sampling.
血液渗透压被认为是水合评价的金标准,但由于技术和侵入性原因,应用有限。55名男性/女性受试者在饮用600毫升水前和30分钟后采集配对的婚前静脉血和指尖毛细血管血。采样方法间无偏倚(0.2 mOsmo/kg,一致性限= -2.5 ~ 2.8 mOsmo/kg),线性相关性高(Spearman’s r = 0.95, P