Myrthe A. Nuijts, Inge Stegeman, Giorgio L. Porro, Carlien A. M. Bennebroek, Tom van Seeters, Frank A. Proudlock, Antoinette Y. N. Schouten – van Meeteren, Saskia M. Imhof
{"title":"Diagnostic accuracy of retinal optical coherence tomography in children with a newly diagnosed brain tumour","authors":"Myrthe A. Nuijts, Inge Stegeman, Giorgio L. Porro, Carlien A. M. Bennebroek, Tom van Seeters, Frank A. Proudlock, Antoinette Y. N. Schouten – van Meeteren, Saskia M. Imhof","doi":"10.1111/aos.15650","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Purpose</h3>\n \n <p>To estimate the diagnostic accuracy of circumpapillary retinal nerve fibre layer (RNFL) thickness and macular ganglion cell layer–inner plexiform layer (GCL-IPL) thickness measurements to discriminate an abnormal visual function (i.e. abnormal age-based visual acuity and/or visual field defect) in children with a newly diagnosed brain tumour.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>This cross-sectional analysis of a prospective longitudinal nationwide cohort study was conducted at four hospitals in the Netherlands, including the national referral centre for paediatric oncology. Patients aged 0–18 years with a newly diagnosed brain tumour and reliable visual acuity and/or visual field examination and optical coherence tomography were included. Diagnostic accuracy was evaluated with sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV).</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Of 115 patients included in the study (67 [58.3%] male; median age 10.6 years [range, 0.2–17.8 years]), reliable RNFL thickness and GCL-IPL thickness measurements were available in 92 patients (80.0%) and 84 patients (73.0%), respectively. The sensitivity for detecting an abnormal visual function was 74.5% for average RNFL thickness and 41.7% for average GCL-IPL thickness at a specificity of 44.5% and 82.9%, respectively. The PPV and NPV were 33.0% and 82.6% for the average RNFL thickness and 57.1% and 82.2% for the average GCL-IPL thickness.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>An abnormal visual function was discriminated correctly by using the average RNFL thickness in seven out of ten patients and by using the average GCL-IPL thickness in four out of ten patients. The relatively high NPVs signified that patients with normal average RNFL thickness and average GCL-IPL thickness measurements had a relative high certainty of a normal visual function.</p>\n </section>\n </div>","PeriodicalId":6915,"journal":{"name":"Acta Ophthalmologica","volume":"101 6","pages":"658-669"},"PeriodicalIF":3.0000,"publicationDate":"2023-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/aos.15650","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Ophthalmologica","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/aos.15650","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose
To estimate the diagnostic accuracy of circumpapillary retinal nerve fibre layer (RNFL) thickness and macular ganglion cell layer–inner plexiform layer (GCL-IPL) thickness measurements to discriminate an abnormal visual function (i.e. abnormal age-based visual acuity and/or visual field defect) in children with a newly diagnosed brain tumour.
Methods
This cross-sectional analysis of a prospective longitudinal nationwide cohort study was conducted at four hospitals in the Netherlands, including the national referral centre for paediatric oncology. Patients aged 0–18 years with a newly diagnosed brain tumour and reliable visual acuity and/or visual field examination and optical coherence tomography were included. Diagnostic accuracy was evaluated with sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV).
Results
Of 115 patients included in the study (67 [58.3%] male; median age 10.6 years [range, 0.2–17.8 years]), reliable RNFL thickness and GCL-IPL thickness measurements were available in 92 patients (80.0%) and 84 patients (73.0%), respectively. The sensitivity for detecting an abnormal visual function was 74.5% for average RNFL thickness and 41.7% for average GCL-IPL thickness at a specificity of 44.5% and 82.9%, respectively. The PPV and NPV were 33.0% and 82.6% for the average RNFL thickness and 57.1% and 82.2% for the average GCL-IPL thickness.
Conclusion
An abnormal visual function was discriminated correctly by using the average RNFL thickness in seven out of ten patients and by using the average GCL-IPL thickness in four out of ten patients. The relatively high NPVs signified that patients with normal average RNFL thickness and average GCL-IPL thickness measurements had a relative high certainty of a normal visual function.
期刊介绍:
Acta Ophthalmologica is published on behalf of the Acta Ophthalmologica Scandinavica Foundation and is the official scientific publication of the following societies: The Danish Ophthalmological Society, The Finnish Ophthalmological Society, The Icelandic Ophthalmological Society, The Norwegian Ophthalmological Society and The Swedish Ophthalmological Society, and also the European Association for Vision and Eye Research (EVER).
Acta Ophthalmologica publishes clinical and experimental original articles, reviews, editorials, educational photo essays (Diagnosis and Therapy in Ophthalmology), case reports and case series, letters to the editor and doctoral theses.