Vincenzo Marchio, Chiara Cinquini, Giacomo Derchi, Bruno Carlo Brevi, Mario Miccoli, Antonio Barone
{"title":"Resonance Frequency Analysis to Assess the Stability of Immediate Implants: A Retrospective Clinical Trial.","authors":"Vincenzo Marchio, Chiara Cinquini, Giacomo Derchi, Bruno Carlo Brevi, Mario Miccoli, Antonio Barone","doi":"10.11607/prd.5971","DOIUrl":null,"url":null,"abstract":"<p><p>Adequate implant primary stability is a key factor to obtain osseointegration and can be measured at insertion by insertion torque (IT) and at different timepoints with resonance frequency analysis (RFA), expressed as an implant stability quotient (ISQ). This retrospective study investigated the correlation between ISQ and IT at implant insertion. All patients who were eligible for this single-cohort retrospective clinical trial were treated with an immediate implant. IT parameters were recorded at implant insertion, and ISQ values were recorded at insertion and at 2-, 4-, and 12-month follow-ups. The study comprised 23 patients who received 32 implants. The mean IT value was 46.87 ± 9.66 Ncm (range: 25 to 65 Ncm), and the mean ISQ value at implant insertion was 71.45 ± 4.24 (range: 63 to 78); these values showed a statistically significant correlation (<i>P</i> < .0001). According to the present data and considering the implant design used in this trial, there is a statistically significant and positive correlation between IT and ISQ values. Thus, ISQ can be used as a reliable method to measure implant stability over time.</p>","PeriodicalId":54948,"journal":{"name":"International Journal of Periodontics & Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Periodontics & Restorative Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/prd.5971","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Adequate implant primary stability is a key factor to obtain osseointegration and can be measured at insertion by insertion torque (IT) and at different timepoints with resonance frequency analysis (RFA), expressed as an implant stability quotient (ISQ). This retrospective study investigated the correlation between ISQ and IT at implant insertion. All patients who were eligible for this single-cohort retrospective clinical trial were treated with an immediate implant. IT parameters were recorded at implant insertion, and ISQ values were recorded at insertion and at 2-, 4-, and 12-month follow-ups. The study comprised 23 patients who received 32 implants. The mean IT value was 46.87 ± 9.66 Ncm (range: 25 to 65 Ncm), and the mean ISQ value at implant insertion was 71.45 ± 4.24 (range: 63 to 78); these values showed a statistically significant correlation (P < .0001). According to the present data and considering the implant design used in this trial, there is a statistically significant and positive correlation between IT and ISQ values. Thus, ISQ can be used as a reliable method to measure implant stability over time.
期刊介绍:
The International Journal of Periodontics & Restorative Dentistry will
publish manuscripts concerned with all aspects of clinical periodontology,
restorative dentistry, and implantology. This includes pertinent research
as well as clinical methodology (their interdependence and relationship
should be addressed where applicable); proceedings of relevant symposia
or conferences; and quality review papers. Original manuscripts are considered for publication on the condition that they have not been published
or submitted for publication elsewhere.