Lukas Hausmanninger, Igor Komnik, Mario Fleiter, Wolfgang Potthast
{"title":"Influence of Surface Geometry on Palm and Fist Contact Pressure Distribution During Strikes With the Hand in Automotive Assembly.","authors":"Lukas Hausmanninger, Igor Komnik, Mario Fleiter, Wolfgang Potthast","doi":"10.1123/jab.2022-0127","DOIUrl":null,"url":null,"abstract":"<p><p>The increase in repetitive strain injuries to the hand underscores the need for assessing and preventing musculoskeletal overuse associated with hand-intensive tasks. This study investigates the risk of overload injuries in soft tissue structures of the hand by analyzing the pressure distribution and location of peak pressure in the hand during snap-fit connection assembly in the automotive industry. The influence of the surface geometry of automotive trim components the pressure distribution and force imparted during strikes with the palm and the fist are investigated in a cohort of 30 subjects with extensive experience installing trim parts with snap-fit connections. Using the palm or fist (ulnar hand side) of the dominant hand, the subjects struck a simulation device with a flat, rounded, or edged surface geometry. The average peak force applied was 600 N (±122 N), nearly 3 times the force required to overcome the technical resistance of the snap-fit connector (220 N). Fist strikes exerted a 40% higher mean peak pressure and 18% higher mean pressure than did palm strikes. The pressure distribution in the region of the thenar eminence and soft tissue of the ulnar side of the hand did not differ between fist strikes on flat and edged surfaces. Considering the delicate anatomy of the hand, especially the hypothenar muscles on the ulnar side, assembling connection claps using the fist instead of the palm may prevent repetitive blunt trauma to the sensitive blood vessels and nerves in the palm.</p>","PeriodicalId":54883,"journal":{"name":"Journal of Applied Biomechanics","volume":"39 4","pages":"246-253"},"PeriodicalIF":1.1000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Biomechanics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1123/jab.2022-0127","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
The increase in repetitive strain injuries to the hand underscores the need for assessing and preventing musculoskeletal overuse associated with hand-intensive tasks. This study investigates the risk of overload injuries in soft tissue structures of the hand by analyzing the pressure distribution and location of peak pressure in the hand during snap-fit connection assembly in the automotive industry. The influence of the surface geometry of automotive trim components the pressure distribution and force imparted during strikes with the palm and the fist are investigated in a cohort of 30 subjects with extensive experience installing trim parts with snap-fit connections. Using the palm or fist (ulnar hand side) of the dominant hand, the subjects struck a simulation device with a flat, rounded, or edged surface geometry. The average peak force applied was 600 N (±122 N), nearly 3 times the force required to overcome the technical resistance of the snap-fit connector (220 N). Fist strikes exerted a 40% higher mean peak pressure and 18% higher mean pressure than did palm strikes. The pressure distribution in the region of the thenar eminence and soft tissue of the ulnar side of the hand did not differ between fist strikes on flat and edged surfaces. Considering the delicate anatomy of the hand, especially the hypothenar muscles on the ulnar side, assembling connection claps using the fist instead of the palm may prevent repetitive blunt trauma to the sensitive blood vessels and nerves in the palm.
期刊介绍:
The mission of the Journal of Applied Biomechanics (JAB) is to disseminate the highest quality peer-reviewed studies that utilize biomechanical strategies to advance the study of human movement. Areas of interest include clinical biomechanics, gait and posture mechanics, musculoskeletal and neuromuscular biomechanics, sport mechanics, and biomechanical modeling. Studies of sport performance that explicitly generalize to broader activities, contribute substantially to fundamental understanding of human motion, or are in a sport that enjoys wide participation, are welcome. Also within the scope of JAB are studies using biomechanical strategies to investigate the structure, control, function, and state (health and disease) of animals.