Experimental Design Application for Measuring Histamine in Tuna Fish Samples by Phenyl Isothiocyanate Derivation Method Using Ultra-Performance Liquid Chromatography.
{"title":"Experimental Design Application for Measuring Histamine in Tuna Fish Samples by Phenyl Isothiocyanate Derivation Method Using Ultra-Performance Liquid Chromatography.","authors":"Maede Ameri, Seyed Mosayeb Daryanavard","doi":"10.1093/chromsci/bmad060","DOIUrl":null,"url":null,"abstract":"<p><p>Histamine as an important biogenic amino acid was measured in tuna fish samples by ultra-performance liquid chromatography using a phenyl isothiocyanate derivative. Minitab software was used to design the experiment and investigate the effective factors during the process, which includes screening and optimization steps. A partial factorial design was used in the screening stage and a central composite design was used in the optimization. Effective parameters in histamine derivatized were examined in the screening step including triethylamine volume, phenyl isothiocyanate volume, reaction temperature, reaction time and mobile phase pH. Then, in the optimization, effective parameters were identified and finally, the calibration curve was drawn from a concentration of 0.5-10.0 μg.mL-1 for histamine derivatized and a correlation coefficient of 0.994 was obtained for histamine derivatized. The method detection limit was 0.36 μg.mL-1 and the limit of quantification (LOQ) was 1.19 μg.mL-1. The relative standard deviation of the method was obtained for concentrations of 1.0-100.0 μg.mL-1 in the range between 1.06 and 2.21%. The recovery method was obtained from 90.8 to 103.1% for measuring histamine derivatized in real fish samples.</p>","PeriodicalId":15430,"journal":{"name":"Journal of chromatographic science","volume":" ","pages":"570-579"},"PeriodicalIF":1.5000,"publicationDate":"2024-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of chromatographic science","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1093/chromsci/bmad060","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Histamine as an important biogenic amino acid was measured in tuna fish samples by ultra-performance liquid chromatography using a phenyl isothiocyanate derivative. Minitab software was used to design the experiment and investigate the effective factors during the process, which includes screening and optimization steps. A partial factorial design was used in the screening stage and a central composite design was used in the optimization. Effective parameters in histamine derivatized were examined in the screening step including triethylamine volume, phenyl isothiocyanate volume, reaction temperature, reaction time and mobile phase pH. Then, in the optimization, effective parameters were identified and finally, the calibration curve was drawn from a concentration of 0.5-10.0 μg.mL-1 for histamine derivatized and a correlation coefficient of 0.994 was obtained for histamine derivatized. The method detection limit was 0.36 μg.mL-1 and the limit of quantification (LOQ) was 1.19 μg.mL-1. The relative standard deviation of the method was obtained for concentrations of 1.0-100.0 μg.mL-1 in the range between 1.06 and 2.21%. The recovery method was obtained from 90.8 to 103.1% for measuring histamine derivatized in real fish samples.
期刊介绍:
The Journal of Chromatographic Science is devoted to the dissemination of information concerning all methods of chromatographic analysis. The standard manuscript is a description of recent original research that covers any or all phases of a specific separation problem, principle, or method. Manuscripts which have a high degree of novelty and fundamental significance to the field of separation science are particularly encouraged. It is expected the authors will clearly state in the Introduction how their method compares in some markedly new and improved way to previous published related methods. Analytical performance characteristics of new methods including sensitivity, tested limits of detection or quantification, accuracy, precision, and specificity should be provided. Manuscripts which describe a straightforward extension of a known analytical method or an application to a previously analyzed and/or uncomplicated sample matrix will not normally be reviewed favorably. Manuscripts in which mass spectrometry is the dominant analytical method and chromatography is of marked secondary importance may be declined.