Verification of Reproducibility of VCS2000 Equipment for Mechanical Measurement of Korean Landrace×Yorkshire (F1), F1×Duroc (LYD) Pig Carcasses.

IF 4.2 3区 农林科学 Q2 FOOD SCIENCE & TECHNOLOGY
Yunhwan Park, Kwantae Kim, Jaeyoung Kim, Jongtae Seo, Jungseok Choi
{"title":"Verification of Reproducibility of VCS2000 Equipment for Mechanical Measurement of Korean Landrace×Yorkshire (F1), F1×Duroc (LYD) Pig Carcasses.","authors":"Yunhwan Park,&nbsp;Kwantae Kim,&nbsp;Jaeyoung Kim,&nbsp;Jongtae Seo,&nbsp;Jungseok Choi","doi":"10.5851/kosfa.2023.e17","DOIUrl":null,"url":null,"abstract":"<p><p>With an increase in meat consumption, the need to measure the weight of each primal cut of pork has increased. Recently, automation devices have been used to measure the weight of each primal cut of pork. The objective of this study was to investigate the accuracy of VCS2000, one of the non-invasive pig carcass analyzers. Production levels of 7 primal cuts of 50 pigs were measured with VCS2000. Average error rates between dissected value for each primal cut and VCS2000 measurement values of ham, shoulder picnic, belly, loin, and shoulder blade were around 5%. Average error rates for spare rib and tenderloin were about 10%. Correlation coefficients between the dissected value and the VCS2000 measured value for ham, shoulder picnic, loin, belly, and shoulder blade were high at 0.66-0.83. Correlation coefficients of spare rib and tenderloin were low at 0.35 and 0.47. Coefficient of determination of the VCS2000 measured value for each primal cut by regression analysis was 0.77 or more for ham, shoulder picnic, loin, and shoulder blade and 0.63 for belly. Coefficients of determination for spare rib and tenderloin were low at 0.40 and 0.27. In addition, the coefficient of determination of VCS2000 for each primal cut was higher than that of the dissected value for all primal cuts. In conclusion, pig carcass analysis using the VCS2000 has a high reliability for pork cuts with high production levels, but a relatively low reliability for pork cuts with low production levels and high fat levels.</p>","PeriodicalId":12459,"journal":{"name":"Food Science of Animal Resources","volume":"43 4","pages":"553-562"},"PeriodicalIF":4.2000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/b0/e8/kosfa-43-4-553.PMC10359848.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Food Science of Animal Resources","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.5851/kosfa.2023.e17","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"FOOD SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

With an increase in meat consumption, the need to measure the weight of each primal cut of pork has increased. Recently, automation devices have been used to measure the weight of each primal cut of pork. The objective of this study was to investigate the accuracy of VCS2000, one of the non-invasive pig carcass analyzers. Production levels of 7 primal cuts of 50 pigs were measured with VCS2000. Average error rates between dissected value for each primal cut and VCS2000 measurement values of ham, shoulder picnic, belly, loin, and shoulder blade were around 5%. Average error rates for spare rib and tenderloin were about 10%. Correlation coefficients between the dissected value and the VCS2000 measured value for ham, shoulder picnic, loin, belly, and shoulder blade were high at 0.66-0.83. Correlation coefficients of spare rib and tenderloin were low at 0.35 and 0.47. Coefficient of determination of the VCS2000 measured value for each primal cut by regression analysis was 0.77 or more for ham, shoulder picnic, loin, and shoulder blade and 0.63 for belly. Coefficients of determination for spare rib and tenderloin were low at 0.40 and 0.27. In addition, the coefficient of determination of VCS2000 for each primal cut was higher than that of the dissected value for all primal cuts. In conclusion, pig carcass analysis using the VCS2000 has a high reliability for pork cuts with high production levels, but a relatively low reliability for pork cuts with low production levels and high fat levels.

Abstract Image

Abstract Image

韩国Landrace×Yorkshire (F1), F1×Duroc (LYD)猪胴体机械测量VCS2000设备的重复性验证。
随着肉类消费量的增加,测量猪肉每一块原切肉重量的需求也在增加。最近,自动化设备被用来测量每一块猪肉的重量。本研究的目的是研究一种非侵入式猪胴体分析仪VCS2000的准确性。用VCS2000测定了50头猪的7个初切的生产水平。每个原始切口的解剖值与VCS2000测量值之间的平均错误率约为5%,其中包括火腿、肩部野餐、腹部、腰部和肩胛骨。排骨和里脊肉的平均错误率约为10%。火腿、肩野餐、腰、腹、肩胛骨的解剖值与VCS2000测量值的相关系数较高,为0.66 ~ 0.83。排骨和里脊的相关系数较低,分别为0.35和0.47。通过回归分析,VCS2000对每个原始切口的测量值的决定系数为:火腿、肩肉、腰肉和肩胛骨为0.77或更多,腹部为0.63。排骨和里脊的决定系数较低,分别为0.40和0.27。此外,VCS2000对每个原始切口的决定系数高于所有原始切口的解剖值。综上所述,使用VCS2000进行猪胴体分析对高产猪肉块具有较高的可靠性,但对低产量和高脂肪猪肉块的可靠性相对较低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Food Science of Animal Resources
Food Science of Animal Resources Agricultural and Biological Sciences-Animal Science and Zoology
CiteScore
6.70
自引率
6.70%
发文量
75
期刊介绍: Food Science of Animal Resources (Food Sci. Anim. Resour.) is an international, peer-reviewed journal publishing original research and review articles on scientific and technological aspects of chemistry, biotechnology, processing, engineering, and microbiology of meat, egg, dairy, and edible insect/worm products.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信