Application of polyetheretherketone (PEEK) posts: evaluation of fracture resistance and stress distribution in the root: in vitro and finite element analyses.

IF 2.5 4区 医学 Q2 Dentistry
Michele Oliveira Lima, Marcela Alvarez Ferretti, Ricardo Armini Caldas, Valentim Adelino Ricardo Barão, Fabiana Mantovani Gomes França, Débora Alves Nunes Leite Lima, Luís Roberto Martins, Flávio Henrique Baggio Aguiar
{"title":"Application of polyetheretherketone (PEEK) posts: evaluation of fracture resistance and stress distribution in the root: in vitro and finite element analyses.","authors":"Michele Oliveira Lima,&nbsp;Marcela Alvarez Ferretti,&nbsp;Ricardo Armini Caldas,&nbsp;Valentim Adelino Ricardo Barão,&nbsp;Fabiana Mantovani Gomes França,&nbsp;Débora Alves Nunes Leite Lima,&nbsp;Luís Roberto Martins,&nbsp;Flávio Henrique Baggio Aguiar","doi":"10.1590/1807-3107bor-2023.vol37.0047","DOIUrl":null,"url":null,"abstract":"<p><p>To evaluate the feasibility of using a milled polyetheretherketone (PEEK) post and core in endodontically treated teeth with or without a ferrule. Sixty bovine tooth roots were endodontically treated followed by cementation of intraradicular retainers (IR), according to each experimental group: a) non-ferrule glass fiber post (f0FP); b) 2-mm-ferrule glass fiber post (f2FP); c) non-ferrule resized glass fiber post (f0PR); d) 2-mm-ferrule resized glass fiber post (f2PR); e) non-ferrule PEEK post and core (f0PPC); and f) 2-mm-ferrule PEEK post and core (f2PPC). Metal crowns were made and cemented. A periodontal ligament was simulated using polyether. A force was applied to the palatine portion of each sample at 45°, until fracture. Fracture resistance data were submitted to two-way ANOVA and Tukey's test (α = 0.05). Three-dimensional digital models were developed to calculate the tensions formed in the root using finite element analysis. Models of glass fiber posts and PEEK posts and cores were evaluated with or without a ferrule. The results were analyzed by the Mohr-Coulomb criterion. The type of IR was not influenced by fracture strength (p = 0.243). There were significant statistical differences among the remaining factors. Ferrule groups had greater fracture resistance, and the failure mode of teeth with a ferrule was more catastrophic than the non-ferrule group. A ferrule increases fracture resistance and influences failure mode; the PEEK post and core did not modify the biomechanics of endodontically treated teeth, and resembled the glass fiber post results. The crack initiation point differed between the ferrule and non-ferrule groups.</p>","PeriodicalId":48942,"journal":{"name":"Brazilian Oral Research","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Oral Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/1807-3107bor-2023.vol37.0047","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 2

Abstract

To evaluate the feasibility of using a milled polyetheretherketone (PEEK) post and core in endodontically treated teeth with or without a ferrule. Sixty bovine tooth roots were endodontically treated followed by cementation of intraradicular retainers (IR), according to each experimental group: a) non-ferrule glass fiber post (f0FP); b) 2-mm-ferrule glass fiber post (f2FP); c) non-ferrule resized glass fiber post (f0PR); d) 2-mm-ferrule resized glass fiber post (f2PR); e) non-ferrule PEEK post and core (f0PPC); and f) 2-mm-ferrule PEEK post and core (f2PPC). Metal crowns were made and cemented. A periodontal ligament was simulated using polyether. A force was applied to the palatine portion of each sample at 45°, until fracture. Fracture resistance data were submitted to two-way ANOVA and Tukey's test (α = 0.05). Three-dimensional digital models were developed to calculate the tensions formed in the root using finite element analysis. Models of glass fiber posts and PEEK posts and cores were evaluated with or without a ferrule. The results were analyzed by the Mohr-Coulomb criterion. The type of IR was not influenced by fracture strength (p = 0.243). There were significant statistical differences among the remaining factors. Ferrule groups had greater fracture resistance, and the failure mode of teeth with a ferrule was more catastrophic than the non-ferrule group. A ferrule increases fracture resistance and influences failure mode; the PEEK post and core did not modify the biomechanics of endodontically treated teeth, and resembled the glass fiber post results. The crack initiation point differed between the ferrule and non-ferrule groups.

聚醚醚酮(PEEK)桩的应用:根部抗断裂性和应力分布的评估:体外和有限元分析。
评价在有卡箍或无卡箍的根管治疗牙齿中使用聚醚醚酮(PEEK)磨桩和核的可行性。对60只牛牙根进行根内治疗,并进行根内固位器(IR)固位,实验组分为:a)无套圈玻璃纤维桩(f0FP);b) 2mm套圈玻璃纤维桩(f2FP);c)无套圈调整玻璃纤维桩(f0PR);d) 2mm套圈调整玻璃纤维桩(f2PR);e)无套圈PEEK桩芯(f0PPC);f) 2mm套圈PEEK桩芯(f2PPC)。制作金属冠并粘接。用聚醚模拟牙周韧带。每个样品的腭部以45°方向受力,直至断裂。断裂阻力数据采用双因素方差分析和Tukey检验(α = 0.05)。建立了三维数字模型,利用有限元分析计算根部形成的张力。模型的玻璃纤维桩和PEEK桩和芯评估有或没有卡箍。用Mohr-Coulomb准则对结果进行了分析。IR类型不受断裂强度的影响(p = 0.243)。其余因素间差异有统计学意义。有卡箍组具有更强的抗断裂能力,且有卡箍组牙的失效模式比无卡箍组更具灾难性。卡箍增加抗断裂能力,影响破坏模式;PEEK桩和核不改变根管治疗后牙齿的生物力学,与玻璃纤维桩的结果相似。有套圈组和无套圈组的裂纹起裂点不同。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Brazilian Oral Research
Brazilian Oral Research DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.70
自引率
4.00%
发文量
107
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信