{"title":"A Sensitive Liquid Chromatography-Mass Spectrometric Method for Determination of Bisoprolol in Rat Serum after Pre-Column Derivatization.","authors":"Huda A Shaheen, Saleh O Bahaffi, Alaa M Khedr","doi":"10.1093/chromsci/bmad056","DOIUrl":null,"url":null,"abstract":"<p><p>Two derivatization regents were reacted with bisoprolol (BIS), followed by liquid-chromatography-mass spectrometric analysis. 3-Bromomethyl-propyphenazone (BMP) and dansyl-chloride (Dns-Cl) were reacted via the secondary amino group using a catalyst to accelerate the reaction progress and completeness with minimal reaction byproducts. The sensitivity and the ionization efficiency of both BIS-methyl-propyphenazone (BIS-MP) and BIS-Dns via electrospray ionization were studied. The sensitivity of BIS-MP was superior to BIS-Dns. The derivatization procedure, extraction procedure, and LC-MS method were optimized and validated to achieve the monitoring of BIS in rat serum at a picogram scale. The calibration curve showed a regression coefficient value of 0.999 within a concentration spanning a range of 10-500 pg/mL. The detection limit and quantitation were 4 and 10 pg/mL, respectively. The intraday and inter-day precision values (% relative standard deviation) ranged from 0.53 to 6.91%, whereas the accuracy values (expressed as % error) ranged from -4.20 to -0.77%. The pharmacokinetic parameters were: 15,280 pg/mL for a maximum concentration of BIS (Cmax) at the maximum time (Tmax) of 1 h. BIS's elimination half-life (t1/2) was determined to be 3 h. The value of the area under the concentration-time curve (AUC0 - t) was 34,370 pg/mL h.</p>","PeriodicalId":15430,"journal":{"name":"Journal of chromatographic science","volume":" ","pages":"668-675"},"PeriodicalIF":1.5000,"publicationDate":"2024-08-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of chromatographic science","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1093/chromsci/bmad056","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Two derivatization regents were reacted with bisoprolol (BIS), followed by liquid-chromatography-mass spectrometric analysis. 3-Bromomethyl-propyphenazone (BMP) and dansyl-chloride (Dns-Cl) were reacted via the secondary amino group using a catalyst to accelerate the reaction progress and completeness with minimal reaction byproducts. The sensitivity and the ionization efficiency of both BIS-methyl-propyphenazone (BIS-MP) and BIS-Dns via electrospray ionization were studied. The sensitivity of BIS-MP was superior to BIS-Dns. The derivatization procedure, extraction procedure, and LC-MS method were optimized and validated to achieve the monitoring of BIS in rat serum at a picogram scale. The calibration curve showed a regression coefficient value of 0.999 within a concentration spanning a range of 10-500 pg/mL. The detection limit and quantitation were 4 and 10 pg/mL, respectively. The intraday and inter-day precision values (% relative standard deviation) ranged from 0.53 to 6.91%, whereas the accuracy values (expressed as % error) ranged from -4.20 to -0.77%. The pharmacokinetic parameters were: 15,280 pg/mL for a maximum concentration of BIS (Cmax) at the maximum time (Tmax) of 1 h. BIS's elimination half-life (t1/2) was determined to be 3 h. The value of the area under the concentration-time curve (AUC0 - t) was 34,370 pg/mL h.
期刊介绍:
The Journal of Chromatographic Science is devoted to the dissemination of information concerning all methods of chromatographic analysis. The standard manuscript is a description of recent original research that covers any or all phases of a specific separation problem, principle, or method. Manuscripts which have a high degree of novelty and fundamental significance to the field of separation science are particularly encouraged. It is expected the authors will clearly state in the Introduction how their method compares in some markedly new and improved way to previous published related methods. Analytical performance characteristics of new methods including sensitivity, tested limits of detection or quantification, accuracy, precision, and specificity should be provided. Manuscripts which describe a straightforward extension of a known analytical method or an application to a previously analyzed and/or uncomplicated sample matrix will not normally be reviewed favorably. Manuscripts in which mass spectrometry is the dominant analytical method and chromatography is of marked secondary importance may be declined.