Biomechanical Response of Head Surrogate With and Without the Helmet.

IF 1.7 4区 医学 Q4 BIOPHYSICS
Abhilash Singh, Devendra Kumar, Shailesh Ganpule
{"title":"Biomechanical Response of Head Surrogate With and Without the Helmet.","authors":"Abhilash Singh, Devendra Kumar, Shailesh Ganpule","doi":"10.1115/1.4062968","DOIUrl":null,"url":null,"abstract":"<p><p>Measurements of brain deformations under injurious loading scenarios are actively sought. In this work, we report experimentally measured head kinematics and corresponding dynamic, two-dimensional brain simulant deformations in head surrogates under a blunt impact, with and without a helmet. Head surrogates used in this work consisted of skin, skull, dura, falx, tentorium, and brain stimulants. The head surrogate geometry was based on the global human body models consortium's head model. A base head surrogate consisting of skin-skull-brain was considered. In addition, the response of two other head surrogates, skin-skull-dura-brain, and skin-skull-dura-brain-falx-tentorium, was investigated. Head surrogate response was studied for sagittal and coronal plane rotations for impactor velocities of 1 and 3 m/s. Response of head surrogates was compared against strain measurements in PMHS. The strain pattern in the brain simulant was heterogenous, and peak strains were established within ∼30 ms. The choice of head surrogate affect the spatiotemporal evolution of strain. For no helmet case, peak MPS of ∼50-60% and peak MSS of ∼35-50% were seen in brain simulant corresponding to peak rotational accelerations of ∼5000-7000 rad/s2. Peak head kinematics and peak MPS have been reduced by up to 75% and 45%, respectively, with the conventional helmet and by up to 90% and 85%, respectively, with the helmet with antirotational pads. Overall, these results provide important, new data on brain simulant strains under a variety of loading scenarios-with and without the helmets.</p>","PeriodicalId":54871,"journal":{"name":"Journal of Biomechanical Engineering-Transactions of the Asme","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomechanical Engineering-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4062968","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Measurements of brain deformations under injurious loading scenarios are actively sought. In this work, we report experimentally measured head kinematics and corresponding dynamic, two-dimensional brain simulant deformations in head surrogates under a blunt impact, with and without a helmet. Head surrogates used in this work consisted of skin, skull, dura, falx, tentorium, and brain stimulants. The head surrogate geometry was based on the global human body models consortium's head model. A base head surrogate consisting of skin-skull-brain was considered. In addition, the response of two other head surrogates, skin-skull-dura-brain, and skin-skull-dura-brain-falx-tentorium, was investigated. Head surrogate response was studied for sagittal and coronal plane rotations for impactor velocities of 1 and 3 m/s. Response of head surrogates was compared against strain measurements in PMHS. The strain pattern in the brain simulant was heterogenous, and peak strains were established within ∼30 ms. The choice of head surrogate affect the spatiotemporal evolution of strain. For no helmet case, peak MPS of ∼50-60% and peak MSS of ∼35-50% were seen in brain simulant corresponding to peak rotational accelerations of ∼5000-7000 rad/s2. Peak head kinematics and peak MPS have been reduced by up to 75% and 45%, respectively, with the conventional helmet and by up to 90% and 85%, respectively, with the helmet with antirotational pads. Overall, these results provide important, new data on brain simulant strains under a variety of loading scenarios-with and without the helmets.

戴头盔和不戴头盔时头部替代物的生物力学反应
我们正在积极寻求对伤害性负载情况下的脑变形进行测量。在这项工作中,我们报告了实验测量的头部运动学和相应的动态二维脑模拟变形,在钝器撞击下,戴头盔和不戴头盔的头部替代物。这项工作中使用的头部替代物包括皮肤、头骨、硬脑膜、颅骨、触角和脑刺激物。头部替代物的几何形状基于全球人体模型联盟的头部模型。考虑了由皮肤-头骨-大脑组成的基本头部替代物。此外,还研究了另外两个头部代用体的反应,即皮肤-颅骨-硬脑膜和皮肤-颅骨-硬脑膜-褶皱-腱膜。在撞击器速度为 1 米/秒和 3 米/秒的情况下,研究了矢状面和冠状面旋转时头部替代物的响应。将头部代用体的响应与 PMHS 中的应变测量值进行了比较。脑模拟物中的应变模式是异质的,峰值应变是在∼30 毫秒内建立的。头部替代物的选择会影响应变的时空演变。在无头盔的情况下,脑模拟物的峰值MPS为50-60%,峰值MSS为35-50%,对应的峰值旋转加速度为5000-7000 rad/s2。传统头盔的头部运动学峰值和 MPS 峰值分别降低了 75% 和 45%,而带防旋转垫的头盔则分别降低了 90% 和 85%。总之,这些结果提供了在各种加载情况下--戴头盔和不戴头盔--大脑模拟应变的重要新数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.40
自引率
5.90%
发文量
169
审稿时长
4-8 weeks
期刊介绍: Artificial Organs and Prostheses; Bioinstrumentation and Measurements; Bioheat Transfer; Biomaterials; Biomechanics; Bioprocess Engineering; Cellular Mechanics; Design and Control of Biological Systems; Physiological Systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信