Scleral fixation of a novel modified, injected canine intraocular lens by haptic capture, in 17 dogs.

IF 1.7 4区 农林科学 Q2 VETERINARY SCIENCES
Veterinary ophthalmology Pub Date : 2025-03-01 Epub Date: 2023-07-06 DOI:10.1111/vop.13129
Gary A Lewin, Christopher J Dixon
{"title":"Scleral fixation of a novel modified, injected canine intraocular lens by haptic capture, in 17 dogs.","authors":"Gary A Lewin, Christopher J Dixon","doi":"10.1111/vop.13129","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The aims of lens removal surgery are to re-establish or preserve both a clear visual axis and emmetropic vision. Trans-scleral intraocular lens (IOL) fixation has been described in cases where lens capsule instability precludes the insertion of a prosthetic intraocular lens into the lens capsule. Previous techniques have necessitated enlargement of the corneal incision to accommodate either a rigid polymethylmethacrylate IOL or an acrylic foldable IOL inserted using forceps. This paper reports the modification of an endocapsular IOL to be used as an injectable suture-fixated IOL introduced through a 2.8 mm corneal incision.</p><p><strong>Materials and methods: </strong>All cases underwent lens extraction by phacoemulsification followed by removal of the unstable lens capsule. A PFI X4 IOL (Medicontur) was modified to create four open-loop haptics. The IOL was injected into the anterior chamber, each haptic was captured in a loop of suture introduced ab externo, and the lens was sutured with four-point fixation.</p><p><strong>Results: </strong>The results from 20 eyes in 17 dogs are reported. Over an average follow-up time of 14.5 months, vision was retained in 16/20 eyes. Vision was lost in four eyes due to corneal ulceration and ocular hypertension (1/20), retinal detachment (2/20), and Progressive Retinal Atrophy (1/20).</p><p><strong>Conclusions: </strong>The modified PFI X4 proved suitable for injection and scleral fixation through a 2.8 mm corneal incision, with a success rate comparable to previously published techniques.</p>","PeriodicalId":23836,"journal":{"name":"Veterinary ophthalmology","volume":" ","pages":"158-167"},"PeriodicalIF":1.7000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary ophthalmology","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1111/vop.13129","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/6 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: The aims of lens removal surgery are to re-establish or preserve both a clear visual axis and emmetropic vision. Trans-scleral intraocular lens (IOL) fixation has been described in cases where lens capsule instability precludes the insertion of a prosthetic intraocular lens into the lens capsule. Previous techniques have necessitated enlargement of the corneal incision to accommodate either a rigid polymethylmethacrylate IOL or an acrylic foldable IOL inserted using forceps. This paper reports the modification of an endocapsular IOL to be used as an injectable suture-fixated IOL introduced through a 2.8 mm corneal incision.

Materials and methods: All cases underwent lens extraction by phacoemulsification followed by removal of the unstable lens capsule. A PFI X4 IOL (Medicontur) was modified to create four open-loop haptics. The IOL was injected into the anterior chamber, each haptic was captured in a loop of suture introduced ab externo, and the lens was sutured with four-point fixation.

Results: The results from 20 eyes in 17 dogs are reported. Over an average follow-up time of 14.5 months, vision was retained in 16/20 eyes. Vision was lost in four eyes due to corneal ulceration and ocular hypertension (1/20), retinal detachment (2/20), and Progressive Retinal Atrophy (1/20).

Conclusions: The modified PFI X4 proved suitable for injection and scleral fixation through a 2.8 mm corneal incision, with a success rate comparable to previously published techniques.

一种新型改良注射犬人工晶状体的触觉捕获巩膜固定,17只犬。
摘晶状体手术的目的是重建或保留清晰的视轴和正视视力。经巩膜人工晶状体(IOL)固定已被描述的情况下,晶状体囊不稳定排除人工晶状体插入到晶状体囊。以前的技术需要扩大角膜切口,以容纳刚性聚甲基丙烯酸甲酯人工晶状体或丙烯酸可折叠人工晶状体。本文报道了一种经2.8 mm角膜切口植入的可注射式人工晶状体。材料和方法:所有病例均行超声乳化术摘除晶状体并取出不稳定晶状体囊。改良PFI X4 IOL (Medicontur),形成四个开环触觉。将人工晶状体注射到前房,每个触觉通过外部引入的缝合环捕获,并采用四点固定缝合晶状体。结果:报道了17只犬20只眼的检查结果。在平均14.5个月的随访时间里,20只眼睛中有16只保持视力。4眼因角膜溃疡和高眼压(1/20)、视网膜脱离(2/20)和进行性视网膜萎缩(1/20)而丧失视力。结论:改良的PFI X4被证明适合于通过2.8 mm角膜切口进行注射和巩膜固定,其成功率与先前发表的技术相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Veterinary ophthalmology
Veterinary ophthalmology 农林科学-兽医学
CiteScore
2.70
自引率
37.50%
发文量
82
审稿时长
12-24 weeks
期刊介绍: Veterinary Ophthalmology is a peer-reviewed, international journal that welcomes submission of manuscripts directed towards academic researchers of veterinary ophthalmology, specialists and general practitioners with a strong ophthalmology interest. Articles include those relating to all aspects of: Clinical and investigational veterinary and comparative ophthalmology; Prospective and retrospective studies or reviews of naturally occurring ocular disease in veterinary species; Experimental models of both animal and human ocular disease in veterinary species; Anatomic studies of the animal eye; Physiological studies of the animal eye; Pharmacological studies of the animal eye.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信