Development of modified laser Doppler flowmetry device for real-time monitoring of esophageal mucosal blood flow: a preclinical assessment with an animal model.
Shun-Ichi Kawarai, Shintaro Katahira, Midori Miyatake, Kota Itagaki, Noriko Tsuruoka, Yoichi Haga, Yoshikatsu Saiki
{"title":"Development of modified laser Doppler flowmetry device for real-time monitoring of esophageal mucosal blood flow: a preclinical assessment with an animal model.","authors":"Shun-Ichi Kawarai, Shintaro Katahira, Midori Miyatake, Kota Itagaki, Noriko Tsuruoka, Yoichi Haga, Yoshikatsu Saiki","doi":"10.1007/s10047-023-01408-w","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to modify a laser Doppler flowmeter designed and assembled at our institute. After measuring sensitivity evaluation in ex vivo experiments, we confirmed the efficacy of this new device for monitoring real-time esophageal mucosal blood flow changes after thoracic stent graft implantation by simulating various clinical situations in an animal model. Thoracic stent graft implantation was performed in a swine model (n = 8). Esophageal mucosal blood flow decreased significantly from baseline (34.1 ± 18.8 ml/min/100 g vs. 16.7 ± 6.6 ml/min/100 g, P < 0.05) in the lower esophagus (Th6-Th8) where the stent graft covered the aorta. In the hemorrhagic shock model (shock index ≥ 1.0), esophageal mucosal blood flow showed a remarkable change from baseline in the upper esophagus (Th1-Th3), where the stent graft did not cover the aorta (20.8 ± 9.8 ml/min/100 g vs. 12.9 ± 8.6 ml/min/100 g, P < 0.01); however, it returned to the baseline value within a 30-min period. Mucosal blood flow remained stable in the esophagus, where the stent graft did not cover the aorta. After elevating the mean blood pressure to > 70 mmHg with continuous intravenous noradrenaline infusion, esophageal mucosal blood flow increased significantly in both regions; however, the reaction was different between the two regions. Our newly developed laser Doppler flowmeter could measure real-time esophageal mucosal blood flow changes in various clinical situations during thoracic stent graft implantation in a swine model. Hence, this device can be applied in many medical fields by downsizing it.</p>","PeriodicalId":15177,"journal":{"name":"Journal of Artificial Organs","volume":" ","pages":"284-292"},"PeriodicalIF":1.1000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-023-01408-w","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/7 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
This study aimed to modify a laser Doppler flowmeter designed and assembled at our institute. After measuring sensitivity evaluation in ex vivo experiments, we confirmed the efficacy of this new device for monitoring real-time esophageal mucosal blood flow changes after thoracic stent graft implantation by simulating various clinical situations in an animal model. Thoracic stent graft implantation was performed in a swine model (n = 8). Esophageal mucosal blood flow decreased significantly from baseline (34.1 ± 18.8 ml/min/100 g vs. 16.7 ± 6.6 ml/min/100 g, P < 0.05) in the lower esophagus (Th6-Th8) where the stent graft covered the aorta. In the hemorrhagic shock model (shock index ≥ 1.0), esophageal mucosal blood flow showed a remarkable change from baseline in the upper esophagus (Th1-Th3), where the stent graft did not cover the aorta (20.8 ± 9.8 ml/min/100 g vs. 12.9 ± 8.6 ml/min/100 g, P < 0.01); however, it returned to the baseline value within a 30-min period. Mucosal blood flow remained stable in the esophagus, where the stent graft did not cover the aorta. After elevating the mean blood pressure to > 70 mmHg with continuous intravenous noradrenaline infusion, esophageal mucosal blood flow increased significantly in both regions; however, the reaction was different between the two regions. Our newly developed laser Doppler flowmeter could measure real-time esophageal mucosal blood flow changes in various clinical situations during thoracic stent graft implantation in a swine model. Hence, this device can be applied in many medical fields by downsizing it.
期刊介绍:
The aim of the Journal of Artificial Organs is to introduce to colleagues worldwide a broad spectrum of important new achievements in the field of artificial organs, ranging from fundamental research to clinical applications. The scope of the Journal of Artificial Organs encompasses but is not restricted to blood purification, cardiovascular intervention, biomaterials, and artificial metabolic organs. Additionally, the journal will cover technical and industrial innovations. Membership in the Japanese Society for Artificial Organs is not a prerequisite for submission.