Veno-venous extracorporeal membrane oxygenation support of pulmonary insufficiency using Avalon Elite® cannula in pediatric patients.

IF 1.1 4区 医学 Q4 ENGINEERING, BIOMEDICAL
Journal of Artificial Organs Pub Date : 2024-09-01 Epub Date: 2023-06-29 DOI:10.1007/s10047-023-01412-0
Satoshi Fujita, Tomoki Ushijima, Gen Shinohara, Shinichiro Oda, Akira Shiose
{"title":"Veno-venous extracorporeal membrane oxygenation support of pulmonary insufficiency using Avalon Elite<sup>®</sup> cannula in pediatric patients.","authors":"Satoshi Fujita, Tomoki Ushijima, Gen Shinohara, Shinichiro Oda, Akira Shiose","doi":"10.1007/s10047-023-01412-0","DOIUrl":null,"url":null,"abstract":"<p><p>The \"Avalon Elite<sup>®</sup>\" cannula is a double-lumen cannula used to establish veno-venous extracorporeal membrane oxygenation support. The reported advantages are that extracorporeal circulation can be established by cannulating through the right internal jugular vein only, and there is less re-circulation than with a two-cannula technique. It is available in a wide range of cannula sizes and can be used in a variety of patients, from children to adults. We herein report three pediatric cases in which an Avalon Elite<sup>®</sup> cannula was useful. The first was a case of acute mitral regurgitation due to idiopathic chordal rupture for postoperative severe lung injury and atelectasis due to cardiogenic pulmonary edema. The second was a case of end-stage radiation pneumonitis for safe transfer to facility of lung transplantation. The third was a convalescent case of fulminant myocarditis with severe atelectasis due to cardiogenic pulmonary edema. In each case, veno-venous extracorporeal membrane oxygenation using an Avalon Elite<sup>®</sup> cannula was established, the expected sufficient support was secured, and a good clinical course was obtained without major complications associated with an Avalon Elite<sup>®</sup> cannula.</p>","PeriodicalId":15177,"journal":{"name":"Journal of Artificial Organs","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-023-01412-0","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/29 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The "Avalon Elite®" cannula is a double-lumen cannula used to establish veno-venous extracorporeal membrane oxygenation support. The reported advantages are that extracorporeal circulation can be established by cannulating through the right internal jugular vein only, and there is less re-circulation than with a two-cannula technique. It is available in a wide range of cannula sizes and can be used in a variety of patients, from children to adults. We herein report three pediatric cases in which an Avalon Elite® cannula was useful. The first was a case of acute mitral regurgitation due to idiopathic chordal rupture for postoperative severe lung injury and atelectasis due to cardiogenic pulmonary edema. The second was a case of end-stage radiation pneumonitis for safe transfer to facility of lung transplantation. The third was a convalescent case of fulminant myocarditis with severe atelectasis due to cardiogenic pulmonary edema. In each case, veno-venous extracorporeal membrane oxygenation using an Avalon Elite® cannula was established, the expected sufficient support was secured, and a good clinical course was obtained without major complications associated with an Avalon Elite® cannula.

Abstract Image

使用 Avalon Elite® 插管为肺功能不全的儿科患者提供静脉-静脉体外膜氧合支持。
Avalon Elite®" 插管是一种双腔插管,用于建立静脉-静脉体外膜氧合支持。据报道,它的优点是只需通过右颈内静脉插管即可建立体外循环,而且与双插管技术相比,再循环更少。它有多种尺寸的插管可供选择,适用于从儿童到成人的各种病人。我们在此报告三个使用 Avalon Elite® 插管的儿科病例。第一个病例是特发性脊索断裂导致的急性二尖瓣反流,术后出现严重肺损伤和心源性肺水肿引起的肺不张。第二例是终末期放射性肺炎病例,用于安全转运至肺移植机构。第三例是一例因心源性肺水肿导致严重肺不张的暴发性心肌炎康复病例。在每个病例中,都使用 Avalon Elite® 插管建立了静脉-静脉体外膜氧合,获得了预期的充分支持,临床疗程良好,没有出现与 Avalon Elite® 插管相关的重大并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Artificial Organs
Journal of Artificial Organs 医学-工程:生物医学
CiteScore
2.80
自引率
15.40%
发文量
68
审稿时长
6-12 weeks
期刊介绍: The aim of the Journal of Artificial Organs is to introduce to colleagues worldwide a broad spectrum of important new achievements in the field of artificial organs, ranging from fundamental research to clinical applications. The scope of the Journal of Artificial Organs encompasses but is not restricted to blood purification, cardiovascular intervention, biomaterials, and artificial metabolic organs. Additionally, the journal will cover technical and industrial innovations. Membership in the Japanese Society for Artificial Organs is not a prerequisite for submission.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信