{"title":"Instrumental dead space and proximal working channel connector design in flexible ureteroscopy: a new concept.","authors":"Jia-Lun Kwok,&nbsp;Vincent De Coninck,&nbsp;Amelia Pietropaolo,&nbsp;Patrick Juliebø-Jones,&nbsp;Eugenio Ventimiglia,&nbsp;Thomas Tailly,&nbsp;Florian Alexander Schmid,&nbsp;Manuela Hunziker,&nbsp;Cédric Poyet,&nbsp;Olivier Traxer,&nbsp;Daniel Eberli,&nbsp;Etienne Xavier Keller","doi":"10.1177/17562872231179332","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The objective of this study was to evaluate a new concept in flexible ureteroscopy: instrumental dead space (IDS). For this purpose, various proximal working channel connector designs, as well as the impact of ancillary devices occupying the working channel were evaluated in currently available flexible ureteroscopes.</p><p><strong>Design and methods: </strong>IDS was defined as the volume of saline irrigation needed to inject at the proximal connector for delivery at the distal working channel tip. Because IDS is related to working channel diameter and length, proximal connector design, as well as occupation of working channel by ancillary devices, these parameters were also reviewed.</p><p><strong>Results: </strong>IDS significantly varied between flexible ureteroscope models, ranging from 1.1 ml for the Pusen bare scopes, to 2.3 ml for Olympus scopes with their 4-way connector (<i>p</i> < 0.001). Proximal connector designs showed a high degree of variability in the number of available Luer locks, valves, seals, angles, and rotative characteristics. The measured length of the working channel of bare scopes ranged between 739 and 854 mm and significantly correlated with measured IDS (<i>R</i><sup>2</sup> = 0.82, <i>p</i> < 0.001). The coupling of scopes with an alternative ancillary proximal connector and the insertion of ancillary devices into the working channel significantly reduced IDS (mean IDS reduction of 0.1 to 0.5 ml; <i>p</i> < 0.001).</p><p><strong>Conclusions: </strong>IDS appears as a new parameter that should be considered for future applications of flexible ureteroscopes. A low IDS seems desirable for several clinical applications. The main factors impacting IDS are working channel and proximal connector design, as well as ancillary devices inserted into the working channel. Future studies should clarify how reducing IDS may affect irrigation flow, intrarenal pressure, and direct in-scope suction, as well as evaluate the most desirable proximal connector design properties.</p>","PeriodicalId":23010,"journal":{"name":"Therapeutic Advances in Urology","volume":"15 ","pages":"17562872231179332"},"PeriodicalIF":2.6000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10291398/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Therapeutic Advances in Urology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/17562872231179332","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The objective of this study was to evaluate a new concept in flexible ureteroscopy: instrumental dead space (IDS). For this purpose, various proximal working channel connector designs, as well as the impact of ancillary devices occupying the working channel were evaluated in currently available flexible ureteroscopes.

Design and methods: IDS was defined as the volume of saline irrigation needed to inject at the proximal connector for delivery at the distal working channel tip. Because IDS is related to working channel diameter and length, proximal connector design, as well as occupation of working channel by ancillary devices, these parameters were also reviewed.

Results: IDS significantly varied between flexible ureteroscope models, ranging from 1.1 ml for the Pusen bare scopes, to 2.3 ml for Olympus scopes with their 4-way connector (p < 0.001). Proximal connector designs showed a high degree of variability in the number of available Luer locks, valves, seals, angles, and rotative characteristics. The measured length of the working channel of bare scopes ranged between 739 and 854 mm and significantly correlated with measured IDS (R2 = 0.82, p < 0.001). The coupling of scopes with an alternative ancillary proximal connector and the insertion of ancillary devices into the working channel significantly reduced IDS (mean IDS reduction of 0.1 to 0.5 ml; p < 0.001).

Conclusions: IDS appears as a new parameter that should be considered for future applications of flexible ureteroscopes. A low IDS seems desirable for several clinical applications. The main factors impacting IDS are working channel and proximal connector design, as well as ancillary devices inserted into the working channel. Future studies should clarify how reducing IDS may affect irrigation flow, intrarenal pressure, and direct in-scope suction, as well as evaluate the most desirable proximal connector design properties.

Abstract Image

Abstract Image

Abstract Image

软输尿管镜下仪器死区及近端工作通道接头设计:新概念。
目的:本研究的目的是评估输尿管软镜下的一个新概念:工具性死腔(IDS)。为此,在目前可用的柔性输尿管镜中,评估了各种近端工作通道连接器设计,以及占用工作通道的辅助装置的影响。设计和方法:IDS被定义为需要在近端连接器注入盐水冲洗量,以便在远端工作通道尖端输送。由于IDS与工作通道直径和长度、近端连接器设计以及辅助设备对工作通道的占用有关,因此也对这些参数进行了回顾。结果:输尿管软镜的IDS在不同型号间差异显著,Pusen裸镜的IDS为1.1 ml,而带4路接头的Olympus镜的IDS为2.3 ml (p R2 = 0.82, pp)。结论:输尿管软镜的IDS是未来应用中需要考虑的一个新参数。在一些临床应用中,低IDS似乎是可取的。影响IDS的主要因素是工作通道和近端连接器的设计,以及插入工作通道的辅助设备。未来的研究应阐明降低IDS如何影响灌洗流量、肾内压和直接范围内吸引,并评估最理想的近端连接器设计特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.70
自引率
0.00%
发文量
39
审稿时长
10 weeks
期刊介绍: Therapeutic Advances in Urology delivers the highest quality peer-reviewed articles, reviews, and scholarly comment on pioneering efforts and innovative studies across all areas of urology. The journal has a strong clinical and pharmacological focus and is aimed at clinicians and researchers in urology, providing a forum in print and online for publishing the highest quality articles in this area. The editors welcome articles of current interest across all areas of urology, including treatment of urological disorders, with a focus on emerging pharmacological therapies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信