Clinical Utility of CT-based Attenuation-correction in Myocardial Perfusion SPECT Imaging.

IF 0.9 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Filiz Hatipoğlu, Neslihan Çetin
{"title":"Clinical Utility of CT-based Attenuation-correction in Myocardial Perfusion SPECT Imaging.","authors":"Filiz Hatipoğlu,&nbsp;Neslihan Çetin","doi":"10.4274/mirt.galenos.2022.68094","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>We aimed to investigate and compare the role of computed tomography (CT)-based attenuation-corrected images (AC) with non-attenuation-corrected images (NAC) obtained by single-photon emission computed tomography/computed tomography (SPECT/CT) myocardial perfusion imaging (MPI).</p><p><strong>Methods: </strong>The data of 124 patients who were applied one-day stress-rest Tc-99m sestamibi SPECT/CT MPI and who had coronary angiography (CAG) results within ±3 months were retrospectively reviewed. AC and NAC images were visually evaluated by two nuclear medicine specialists in a consensus. CAG results were used as the reference standard.</p><p><strong>Results: </strong>Specificity, sensitivity, and accuracy were calculated as 66%, 61%, 71%, 79% and 69%, 70% for AC and NAC imaging in the whole group, respectively. There was no statistically significant difference between AC and NAC images for specificity, sensitivity, and accuracy in the male and female subgroups. In the diagnosis of right coronary artery (RCA) disease, CT AC significantly increased the specificity from 87% to 96%. However, in the left anterior descending artery (LAD) region, the specificity was significantly reduced from 95% to 77%.</p><p><strong>Conclusion: </strong>CT-based AC did not significantly contribute to diagnostic performance for increased specificity for the RCA and reduced specificity in the LAD region. Therefore, AC images should always be evaluated side by side with NAC images to benefit from the different advantages of both techniques.</p>","PeriodicalId":44681,"journal":{"name":"Molecular Imaging and Radionuclide Therapy","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2023-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/74/8a/MIRT-32-138.PMC10284174.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Molecular Imaging and Radionuclide Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4274/mirt.galenos.2022.68094","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: We aimed to investigate and compare the role of computed tomography (CT)-based attenuation-corrected images (AC) with non-attenuation-corrected images (NAC) obtained by single-photon emission computed tomography/computed tomography (SPECT/CT) myocardial perfusion imaging (MPI).

Methods: The data of 124 patients who were applied one-day stress-rest Tc-99m sestamibi SPECT/CT MPI and who had coronary angiography (CAG) results within ±3 months were retrospectively reviewed. AC and NAC images were visually evaluated by two nuclear medicine specialists in a consensus. CAG results were used as the reference standard.

Results: Specificity, sensitivity, and accuracy were calculated as 66%, 61%, 71%, 79% and 69%, 70% for AC and NAC imaging in the whole group, respectively. There was no statistically significant difference between AC and NAC images for specificity, sensitivity, and accuracy in the male and female subgroups. In the diagnosis of right coronary artery (RCA) disease, CT AC significantly increased the specificity from 87% to 96%. However, in the left anterior descending artery (LAD) region, the specificity was significantly reduced from 95% to 77%.

Conclusion: CT-based AC did not significantly contribute to diagnostic performance for increased specificity for the RCA and reduced specificity in the LAD region. Therefore, AC images should always be evaluated side by side with NAC images to benefit from the different advantages of both techniques.

Abstract Image

Abstract Image

Abstract Image

基于ct的心肌灌注SPECT成像衰减校正的临床应用。
目的:研究并比较基于计算机断层扫描(CT)的衰减校正图像(AC)与通过单光子发射计算机断层扫描/计算机断层扫描(SPECT/CT)心肌灌注成像(MPI)获得的非衰减校正图像(NAC)的作用。方法:回顾性分析124例应用1天压力休息Tc-99m sestamibi SPECT/CT MPI并在±3个月内进行冠状动脉造影(CAG)结果的患者的资料。AC和NAC图像由两名核医学专家在共识下进行视觉评估。CAG结果作为参考标准。结果:全组AC和NAC成像的特异性、敏感性和准确性分别为66%、61%、71%、79%和69%、70%。在男性和女性亚组中,AC和NAC图像的特异性、敏感性和准确性没有统计学差异。在右冠状动脉(RCA)疾病的诊断中,CT AC的特异性从87%显著提高到96%。然而,在左前降支(LAD)区域,特异性从95%显著降低到77%。结论:基于ct的AC对RCA的特异性增加,对LAD的特异性降低,对诊断性能没有显著贡献。因此,应始终将AC图像与NAC图像并排评估,以从两种技术的不同优势中获益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Molecular Imaging and Radionuclide Therapy
Molecular Imaging and Radionuclide Therapy RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.30
自引率
0.00%
发文量
50
期刊介绍: Molecular Imaging and Radionuclide Therapy (Mol Imaging Radionucl Ther, MIRT) is publishes original research articles, invited reviews, editorials, short communications, letters, consensus statements, guidelines and case reports with a literature review on the topic, in the field of molecular imaging, multimodality imaging, nuclear medicine, radionuclide therapy, radiopharmacy, medical physics, dosimetry and radiobiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信