Short-Term functional comparison of three total knee arthroplasties-Journey II, Genesis II and Profix.

IF 1.3 4区 医学 Q3 ORTHOPEDICS
Daniel Guta, Alasdair Ja Santini, Matt Gornall, Andrew Phillipson, John S Davidson, Joanne Banks, Jill A Pope, Joanne Yorke
{"title":"Short-Term functional comparison of three total knee arthroplasties-Journey II, Genesis II and Profix.","authors":"Daniel Guta,&nbsp;Alasdair Ja Santini,&nbsp;Matt Gornall,&nbsp;Andrew Phillipson,&nbsp;John S Davidson,&nbsp;Joanne Banks,&nbsp;Jill A Pope,&nbsp;Joanne Yorke","doi":"10.1177/10225536231169572","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim of the study: </strong>To compare the outcomes of three knee arthroplasty design philosophies and surface tribology.• A zirconium-surfaced, bicruciate-stabilised implant designed to mimic kinematic movement and improve flexion and outcomes;• A cobalt-chrome surfaced, multi-radius design with built-in femoral external rotation to aid balancing and patella tracking through a deeper trochlea groove;• A zirconium-surfaced, single-radius implant designed on surface conformity, particularly within the patello-femoral joint.</p><p><strong>Methods: </strong>313 knee replacements - 103 <i>Journey II,</i> 103 <i>Genesis II</i> and 107 <i>Profix</i> - were statistically assessed at a minimum of 2 years using WOMAC, Oxford and SF-12 scores, and range of movement.</p><p><strong>Results: </strong>There was no difference between the actual or unit change in WOMAC scores (<i>p</i> = 0.140 and <i>p</i> = 0.287), SF-12 physical (<i>p</i> = 0.088) or mental scores (<i>p</i> = 0.975) between the three implants; or between the actual or unit change in Oxford score (<i>p</i> = 0.912 and <i>p</i> = 0.874) for the <i>Journey II</i> or <i>Genesis II</i>. The <i>Journey II</i> produced more flexion and range of movement than the <i>Genesis II</i> (<i>p</i> < 0.001 and <i>p</i> = 0.018) and <i>Profix</i> (<i>p</i> < 0.001 and <0.001) with no difference between the latter two (<i>p</i> = 0.402 and 0.568); with no difference in extension between the three implants (<i>p</i> = 0.086). There was no difference between those with or without a resurfaced patella.</p><p><strong>Conclusion: </strong>The three design philosophies and surfaces yielded no difference in outcome scores at 2 years post-operatively. The <i>Journey II</i> demonstrated better post-operative flexion. Resurfacing the patella did not alter the outcome scores or flexion.</p>","PeriodicalId":48794,"journal":{"name":"Journal of Orthopaedic Surgery","volume":"31 1","pages":"10225536231169572"},"PeriodicalIF":1.3000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/10225536231169572","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Aim of the study: To compare the outcomes of three knee arthroplasty design philosophies and surface tribology.• A zirconium-surfaced, bicruciate-stabilised implant designed to mimic kinematic movement and improve flexion and outcomes;• A cobalt-chrome surfaced, multi-radius design with built-in femoral external rotation to aid balancing and patella tracking through a deeper trochlea groove;• A zirconium-surfaced, single-radius implant designed on surface conformity, particularly within the patello-femoral joint.

Methods: 313 knee replacements - 103 Journey II, 103 Genesis II and 107 Profix - were statistically assessed at a minimum of 2 years using WOMAC, Oxford and SF-12 scores, and range of movement.

Results: There was no difference between the actual or unit change in WOMAC scores (p = 0.140 and p = 0.287), SF-12 physical (p = 0.088) or mental scores (p = 0.975) between the three implants; or between the actual or unit change in Oxford score (p = 0.912 and p = 0.874) for the Journey II or Genesis II. The Journey II produced more flexion and range of movement than the Genesis II (p < 0.001 and p = 0.018) and Profix (p < 0.001 and <0.001) with no difference between the latter two (p = 0.402 and 0.568); with no difference in extension between the three implants (p = 0.086). There was no difference between those with or without a resurfaced patella.

Conclusion: The three design philosophies and surfaces yielded no difference in outcome scores at 2 years post-operatively. The Journey II demonstrated better post-operative flexion. Resurfacing the patella did not alter the outcome scores or flexion.

三种全膝关节置换术- journey II, Genesis II和Profix的短期功能比较。
研究的目的:比较三种膝关节置换术的设计理念和表面摩擦学的结果。•一种钴铬表面的多半径设计,内置股骨外旋,帮助平衡和髌骨通过更深的滑车槽跟踪;•一种锆表面的单半径植入物设计在表面一致性上,特别是在髌骨-股骨关节内。方法:313例膝关节置换术- 103例Journey II, 103例Genesis II和107例Profix -在至少2年内使用WOMAC, Oxford和SF-12评分和活动范围进行统计评估。结果:三种种植体在WOMAC评分(p = 0.140和p = 0.287)、SF-12生理评分(p = 0.088)和心理评分(p = 0.975)上的实际变化和单位变化无显著差异;或者在《Journey II》或《Genesis II》中牛津分数的实际或单位变化之间(p = 0.912和p = 0.874)。Journey II比Genesis II (p < 0.001和p = 0.018)和Profix (p < 0.001和p = 0.402和0.568)产生更多的屈曲和活动范围;三种种植体的伸展无差异(p = 0.086)。有或没有髌骨置换的患者之间没有差异。结论:三种设计理念和表面在术后2年的预后评分上没有差异。Journey II显示出更好的术后屈曲。髌骨表面置换不改变预后评分或屈曲。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Orthopaedic Surgery
Journal of Orthopaedic Surgery ORTHOPEDICS-SURGERY
CiteScore
3.10
自引率
0.00%
发文量
91
审稿时长
13 weeks
期刊介绍: Journal of Orthopaedic Surgery is an open access peer-reviewed journal publishing original reviews and research articles on all aspects of orthopaedic surgery. It is the official journal of the Asia Pacific Orthopaedic Association. The journal welcomes and will publish materials of a diverse nature, from basic science research to clinical trials and surgical techniques. The journal encourages contributions from all parts of the world, but special emphasis is given to research of particular relevance to the Asia Pacific region.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信