Fluorescence-aided identification technique using a low-cost violet flashlight and rotatory instruments for dental trauma splint removal.

IF 2.3 3区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Dental Traumatology Pub Date : 2023-12-01 Epub Date: 2023-06-21 DOI:10.1111/edt.12864
Andomar Bruno Fernandes Vilela, Priscilla Barbosa Ferreira Soares, Fernanda Silva Gonçalves, Thiago Leite Beaini, Thiago Silva Peres, Carlos José Soares
{"title":"Fluorescence-aided identification technique using a low-cost violet flashlight and rotatory instruments for dental trauma splint removal.","authors":"Andomar Bruno Fernandes Vilela, Priscilla Barbosa Ferreira Soares, Fernanda Silva Gonçalves, Thiago Leite Beaini, Thiago Silva Peres, Carlos José Soares","doi":"10.1111/edt.12864","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/aim: </strong>Removing resin composites used for bonding dental trauma splints may result in irreversible damage to the enamel. This in vitro study evaluated the influence of additional violet illumination and different bur types on damage caused to tooth enamel.</p><p><strong>Materials and methods: </strong>Fifteen maxillary models with four bovine incisor teeth were prepared. All models were scanned using a laboratory scanning system (s600 ARTI; Zirkonzahn). Six experimental groups (n = 10) were generated by two study factors: lighting type (three levels), (1) low-cost (5-7 US$) violet LED flashlight (LUATEK, LT 408); (2) VALO Cordless light curing unit (Ultradent) with black lens; or (3) without additional illumination; and rotatory instrument (two levels), (1) diamond bur or (2) multifluted tungsten-carbide bur. New scanning was performed after splint removal, and the generated files were superimposed on the initial scans using Cumulus software. The light emitted by both violet light sources was characterized by using integrating sphere and beam profile. A qualitative and quantitative analysis of enamel damage and two-way ANOVA followed by Tukey's post hoc was used at an α = 0.05.</p><p><strong>Results: </strong>The use of low-cost violet flashlight that emitted the violet peak light at 385 nm and VALO Cordless with black lens at 396 nm resulted in significantly lower damage to the enamel surface than those in the groups without additional violet light (p < .001). An interaction between rotatory instruments and lighting was found. When no additional violet lighting was used, the diamond bur presented higher mean and maximum depth values.</p><p><strong>Conclusions: </strong>Fluorescence lighting facilitated the removal of remnant resin composite dental trauma splints, leading to less invasive treatment. The diamond bur resulted in higher enamel damage than that affected by the multifluted bur when no violet lighting was used. A low-cost violet flashlight is a useful fluorescence-aided identification technique for removing resin composite dental trauma splints.</p>","PeriodicalId":55180,"journal":{"name":"Dental Traumatology","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Traumatology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/edt.12864","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/21 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 2

Abstract

Background/aim: Removing resin composites used for bonding dental trauma splints may result in irreversible damage to the enamel. This in vitro study evaluated the influence of additional violet illumination and different bur types on damage caused to tooth enamel.

Materials and methods: Fifteen maxillary models with four bovine incisor teeth were prepared. All models were scanned using a laboratory scanning system (s600 ARTI; Zirkonzahn). Six experimental groups (n = 10) were generated by two study factors: lighting type (three levels), (1) low-cost (5-7 US$) violet LED flashlight (LUATEK, LT 408); (2) VALO Cordless light curing unit (Ultradent) with black lens; or (3) without additional illumination; and rotatory instrument (two levels), (1) diamond bur or (2) multifluted tungsten-carbide bur. New scanning was performed after splint removal, and the generated files were superimposed on the initial scans using Cumulus software. The light emitted by both violet light sources was characterized by using integrating sphere and beam profile. A qualitative and quantitative analysis of enamel damage and two-way ANOVA followed by Tukey's post hoc was used at an α = 0.05.

Results: The use of low-cost violet flashlight that emitted the violet peak light at 385 nm and VALO Cordless with black lens at 396 nm resulted in significantly lower damage to the enamel surface than those in the groups without additional violet light (p < .001). An interaction between rotatory instruments and lighting was found. When no additional violet lighting was used, the diamond bur presented higher mean and maximum depth values.

Conclusions: Fluorescence lighting facilitated the removal of remnant resin composite dental trauma splints, leading to less invasive treatment. The diamond bur resulted in higher enamel damage than that affected by the multifluted bur when no violet lighting was used. A low-cost violet flashlight is a useful fluorescence-aided identification technique for removing resin composite dental trauma splints.

荧光辅助识别技术使用低成本的紫色手电筒和旋转仪器在牙外伤夹板移除。
背景/目的:去除用于粘接牙外伤夹板的树脂复合材料可能会对牙釉质造成不可逆的损伤。本研究评估了紫光照射和不同类型牙釉质对牙釉质损伤的影响。材料与方法:制备上颌模型15个,共4颗牛切牙。所有模型均采用实验室扫描系统(s600 ARTI;Zirkonzahn)。根据两个研究因素:照明类型(三个级别),(1)低成本(5-7美元)紫光LED手电筒(LUATEK, LT 408),共分为6个实验组(n = 10);(2) VALO无绳光固化装置(Ultradent),黑色镜头;或(3)无额外照明;旋转仪器(两级),(1)金刚石钎焊或(2)多槽碳化钨钎焊。移除夹板后进行新的扫描,并使用Cumulus软件将生成的文件叠加在初始扫描上。利用积分球和光束轮廓对两种紫光源发出的光进行了表征。对牙釉质损伤进行定性和定量分析,采用双因素方差分析,并采用Tukey’s事后分析,α = 0.05。结果:使用低成本的紫光手电筒照射385 nm的紫光峰值,使用VALO Cordless手电筒照射396 nm的黑色镜片,与不加紫光照射组相比,对牙釉质表面的损伤明显降低(p)。结论:荧光照射有助于去除残余树脂复合牙外伤夹板,减少了治疗的创伤。在不使用紫光照明的情况下,钻石钻对牙釉质的损害比多槽钻对牙釉质的损害更严重。一种低成本的紫色手电筒是一种有用的荧光辅助识别技术,用于去除树脂复合牙外伤夹板。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Dental Traumatology
Dental Traumatology 医学-牙科与口腔外科
CiteScore
6.40
自引率
32.00%
发文量
85
审稿时长
6-12 weeks
期刊介绍: Dental Traumatology is an international journal that aims to convey scientific and clinical progress in all areas related to adult and pediatric dental traumatology. This includes the following topics: - Epidemiology, Social Aspects, Education, Diagnostics - Esthetics / Prosthetics/ Restorative - Evidence Based Traumatology & Study Design - Oral & Maxillofacial Surgery/Transplant/Implant - Pediatrics and Orthodontics - Prevention and Sports Dentistry - Endodontics and Periodontal Aspects The journal"s aim is to promote communication among clinicians, educators, researchers, and others interested in the field of dental traumatology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信