Clinical performance of implant-supported single hybrid abutment crown restoration: A systematic review and meta-analysis.

IF 4.3 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC
ACS Applied Electronic Materials Pub Date : 2024-01-16 Epub Date: 2023-06-13 DOI:10.2186/jpr.JPR_D_22_00279
Mengze Zhang, Dominic King Lun Ho, George Pelekos, Melissa Rachel Fok
{"title":"Clinical performance of implant-supported single hybrid abutment crown restoration: A systematic review and meta-analysis.","authors":"Mengze Zhang, Dominic King Lun Ho, George Pelekos, Melissa Rachel Fok","doi":"10.2186/jpr.JPR_D_22_00279","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate survival rates and technical and biological complications of one-piece screw-retained hybrid abutments in implant-supported single crowns (SCs).</p><p><strong>Study selection: </strong>An electronic search was performed on five databases for clinical studies involving implant-supported single hybrid abutment crowns constructed using titanium-base (Ti base) abutments, with at least 12 months of follow-up. The RoB 2, Robins-I, and JBI tools were used to assess the risk of bias for the different study types. Success, survival, and complication rates were calculated, and a meta-analysis was performed to obtain a pooled estimate. Peri-implant health parameters were extracted and analyzed.</p><p><strong>Results: </strong>22 records (20 studies) were included in this analysis. Direct comparisons between screw-retained hybrid abutment SCs and cemented SCs showed no significant differences in the 1-year survival and success rates. For SCs using a hybrid abutment crown design, their 1-year survival rate was 100% (95% CI: 100%-100%, I<sup>2</sup> = 0.0%, P = 0.984), and a success rate of 99% (95% CI: 97%-100%, I<sup>2</sup> = 50.3%, P = 0.023) was calculated. No confounding variables significantly affected the estimates. The individual technical complication rate was low at 1-year follow-up. The estimated incidence of all types of complications in hybrid abutment SCs is less than 1%.</p><p><strong>Conclusions: </strong>Within the limitations of this study, implant-supported SCs using a hybrid abutment crown design showed favorable short-term clinical outcomes. Additional well-designed clinical trials with at least a 5-year observation period are required to confirm their long-term clinical performance.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2186/jpr.JPR_D_22_00279","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/6/13 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate survival rates and technical and biological complications of one-piece screw-retained hybrid abutments in implant-supported single crowns (SCs).

Study selection: An electronic search was performed on five databases for clinical studies involving implant-supported single hybrid abutment crowns constructed using titanium-base (Ti base) abutments, with at least 12 months of follow-up. The RoB 2, Robins-I, and JBI tools were used to assess the risk of bias for the different study types. Success, survival, and complication rates were calculated, and a meta-analysis was performed to obtain a pooled estimate. Peri-implant health parameters were extracted and analyzed.

Results: 22 records (20 studies) were included in this analysis. Direct comparisons between screw-retained hybrid abutment SCs and cemented SCs showed no significant differences in the 1-year survival and success rates. For SCs using a hybrid abutment crown design, their 1-year survival rate was 100% (95% CI: 100%-100%, I2 = 0.0%, P = 0.984), and a success rate of 99% (95% CI: 97%-100%, I2 = 50.3%, P = 0.023) was calculated. No confounding variables significantly affected the estimates. The individual technical complication rate was low at 1-year follow-up. The estimated incidence of all types of complications in hybrid abutment SCs is less than 1%.

Conclusions: Within the limitations of this study, implant-supported SCs using a hybrid abutment crown design showed favorable short-term clinical outcomes. Additional well-designed clinical trials with at least a 5-year observation period are required to confirm their long-term clinical performance.

种植体支持的单混合基台冠修复的临床表现:系统回顾与荟萃分析。
目的:研究种植体支持的单冠(SC)中一体式螺钉固位混合基台的存活率以及技术和生物学并发症:在五个数据库中对使用钛基(Ti base)基台制作的种植体支持单冠混合基台的临床研究进行了电子检索,并进行了至少 12 个月的随访。使用 RoB 2、Robins-I 和 JBI 工具来评估不同研究类型的偏倚风险。计算了成功率、存活率和并发症发生率,并进行了荟萃分析以获得综合估计值。提取并分析了种植体周围的健康参数。螺丝固位混合基台SC与粘结基台SC的直接比较显示,两者的1年存活率和成功率没有显著差异。对于使用混合基台冠设计的 SC,其 1 年存活率为 100%(95% CI:100%-100%,I2 = 0.0%,P = 0.984),成功率为 99%(95% CI:97%-100%,I2 = 50.3%,P = 0.023)。没有混杂变量对估计值产生明显影响。随访一年时,单项技术并发症发生率较低。混合基台SC各类并发症的估计发生率低于1%:在本研究的限制条件下,使用混合基台冠设计的种植体支持SC显示出良好的短期临床效果。要确认其长期临床表现,还需要进行至少 5 年观察期的其他设计良好的临床试验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信