Three-Dimensional Evaluation of Autogenous Ramus Block Graft Donor Site and Its Relation to Mandibular Canal.

IF 1.5 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Emel Tuğba Ataman-Duruel, Nazan Ece Erduran, Onurcem Duruel, Marco Cicciu, Tolga Fikret Tözüm
{"title":"Three-Dimensional Evaluation of Autogenous Ramus Block Graft Donor Site and Its Relation to Mandibular Canal.","authors":"Emel Tuğba Ataman-Duruel,&nbsp;Nazan Ece Erduran,&nbsp;Onurcem Duruel,&nbsp;Marco Cicciu,&nbsp;Tolga Fikret Tözüm","doi":"10.1563/aaid-joi-D-21-00218","DOIUrl":null,"url":null,"abstract":"<p><p>Sufficient bone volume is necessary for placing a dental implant in an ideal position. To restore severely insufficient bone volume, autogenous block graft procedures with various intraoral donor sites are presented in the literature. The aims of this retrospective study are to present the dimensions and volume of the potential ramus block graft site, and to evaluate possible effect of mandibular canal diameter and its position in relation to mandibular ramus block graft volume. Two-hundred cone-beam computed tomography (CBCT) images were evaluated. The maximum length, width, height, and volume of the potential ramus block graft site, mandibular canal diameter, mandibular canal-mandibular basis distance, and mandibular canal-crest distance were measured. Mandibular canal diameter, mandibular canal-crest distance, and mandibular canal-mandibular basis distance were 3.139 ± 0.446 mm, 15.376 ± 2.562, and 7.834 ± 1.285 mm, respectively. In addition, the dimensions of the potential ramus block graft sites were measured 11.156 ± 2.297 mm × 10.390 ± 3.420 mm × 8.816 ± 1.720 mm (height × length × width). Moreover, the potential ramus bone block volume was calculated as 1.076 ± 0.398 cm3. While a positive correlation was detected between mandibular canal-crest distance and the potential ramus block graft volume (r = .160, P = .025), a negative correlation was found between mandibular canal-mandibular basis distance and the potential ramus block graft volume (r = -.020, P = .001). Mandibular ramus is one of the predictable intraoral donor sites for bone augmentation procedures. However, ramus has some volumetric limitations related to its neighboring anatomic structures. It seems to be important to evaluate lower jaw in a 3-dimensional manner to prevent surgical complications.</p>","PeriodicalId":50101,"journal":{"name":"Journal of Oral Implantology","volume":"49 3","pages":"233-237"},"PeriodicalIF":1.5000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Oral Implantology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1563/aaid-joi-D-21-00218","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Sufficient bone volume is necessary for placing a dental implant in an ideal position. To restore severely insufficient bone volume, autogenous block graft procedures with various intraoral donor sites are presented in the literature. The aims of this retrospective study are to present the dimensions and volume of the potential ramus block graft site, and to evaluate possible effect of mandibular canal diameter and its position in relation to mandibular ramus block graft volume. Two-hundred cone-beam computed tomography (CBCT) images were evaluated. The maximum length, width, height, and volume of the potential ramus block graft site, mandibular canal diameter, mandibular canal-mandibular basis distance, and mandibular canal-crest distance were measured. Mandibular canal diameter, mandibular canal-crest distance, and mandibular canal-mandibular basis distance were 3.139 ± 0.446 mm, 15.376 ± 2.562, and 7.834 ± 1.285 mm, respectively. In addition, the dimensions of the potential ramus block graft sites were measured 11.156 ± 2.297 mm × 10.390 ± 3.420 mm × 8.816 ± 1.720 mm (height × length × width). Moreover, the potential ramus bone block volume was calculated as 1.076 ± 0.398 cm3. While a positive correlation was detected between mandibular canal-crest distance and the potential ramus block graft volume (r = .160, P = .025), a negative correlation was found between mandibular canal-mandibular basis distance and the potential ramus block graft volume (r = -.020, P = .001). Mandibular ramus is one of the predictable intraoral donor sites for bone augmentation procedures. However, ramus has some volumetric limitations related to its neighboring anatomic structures. It seems to be important to evaluate lower jaw in a 3-dimensional manner to prevent surgical complications.

自体支块移植供体的三维评价及其与下颌骨管的关系。
足够的骨容量是将牙种植体放置在理想位置所必需的。为了恢复严重不足的骨容量,文献中提出了各种口腔内供体部位的自体骨块移植手术。本回顾性研究的目的是展示潜在支块移植部位的尺寸和体积,并评估下颌管直径及其位置对下颌支块移植体积的可能影响。评估了200张锥形束计算机断层扫描(CBCT)图像。测量潜在支块移植部位的最大长度、宽度、高度、体积、下颌管直径、下颌管与下颌基间距离、下颌管与下颌冠间距离。下颌管径为3.139±0.446 mm,下颌管-牙冠距离为15.376±2.562 mm,下颌管-基底距离为7.834±1.285 mm。此外,测量了潜在支块移植位点的尺寸为11.156±2.297 mm × 10.390±3.420 mm × 8.816±1.720 mm(高×长×宽)。计算出潜在分支骨块体积为1.076±0.398 cm3。下颌管-嵴距离与潜在支块移植物体积呈正相关(r = 0.160, P = 0.025),而下颌管-下颌基距与潜在支块移植物体积呈负相关(r = -)。020, p = .001)。下颌支是一个可预测的口腔内供体部位骨增强手术。然而,分支的体积受其邻近解剖结构的限制。因此,对下颌进行三维评估以预防手术并发症显得尤为重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Oral Implantology
Journal of Oral Implantology DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.30
自引率
6.20%
发文量
54
审稿时长
6-12 weeks
期刊介绍: The official publication of the American Academy of Implant Dentistry and of the American Academy of Implant Prosthodontics, is dedicated to providing valuable information to general dentists, oral surgeons, prosthodontists, periodontists, scientists, clinicians, laboratory owners and technicians, manufacturers, and educators. Implant basics, prosthetics, pharmaceuticals, the latest research in implantology, implant surgery, and advanced implant procedures are just some of the topics covered.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信