Luminex Crossmatch in kidney transplantation.

IF 4.1 4区 医学 Q2 IMMUNOLOGY
Radouan Fadi Ameur, Lilya Meriem Berkani, Brahim Belaid, Khadidja Habchi, Messaoud Saidani, Reda Djidjik
{"title":"Luminex Crossmatch in kidney transplantation.","authors":"Radouan Fadi Ameur,&nbsp;Lilya Meriem Berkani,&nbsp;Brahim Belaid,&nbsp;Khadidja Habchi,&nbsp;Messaoud Saidani,&nbsp;Reda Djidjik","doi":"10.1111/sji.13279","DOIUrl":null,"url":null,"abstract":"<p><p>The introduction of the Luminex Crossmatch assay (LumXm) which uses Luminex bead technology, consists of extracting the donor's Human Leukocyte Antigen (HLA) molecules from their lymphocytes, and binding them to fluorescent beads that are put in contact with recipient's serum. HLA donor-specific antibodies (DSA) are detected using a fluorescent conjugate. The goal of our study is to determine the benefits of using LumXm in a renal transplantation algorithm. We tested 78 recipients' sera using the LumXm, and the results were compared with the Luminex single antigen bead assay (SAB) for all sera, as well as the Flow Cytometry Crossmatch (FCXM) for 46 sera. We compared our results with those of SAB using 3 cutoffs, the first being the manufacturer's criteria where sensitivity and specificity were at 62.5% and 91.3% respectively for HLA class 1, and 88.5% and 50.0% respectively for HLA class 2. When using the third cutoff criteria (≥2 Adjusted values + MFI [Mean fluorescence intensity] >500 + Neg MFI < 500), the sensitivity increased to 69.0% for HLA class 1 and decreased to 84.0% for HLA class 2, while the specificity increased for HLA class 1 and 2. When comparing with FCXM, the 3 assays agreed in 55.8% of results for class 1 and 2 alike. However, major discrepancies were found for two groups in HLA class 1 and one in HLA class 2. The LumXm when used with other techniques to overcome its' weak points, can provide an interesting insight into the patient's HLA-DSA profile.</p>","PeriodicalId":21493,"journal":{"name":"Scandinavian Journal of Immunology","volume":"98 1","pages":"e13279"},"PeriodicalIF":4.1000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian Journal of Immunology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/sji.13279","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"IMMUNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The introduction of the Luminex Crossmatch assay (LumXm) which uses Luminex bead technology, consists of extracting the donor's Human Leukocyte Antigen (HLA) molecules from their lymphocytes, and binding them to fluorescent beads that are put in contact with recipient's serum. HLA donor-specific antibodies (DSA) are detected using a fluorescent conjugate. The goal of our study is to determine the benefits of using LumXm in a renal transplantation algorithm. We tested 78 recipients' sera using the LumXm, and the results were compared with the Luminex single antigen bead assay (SAB) for all sera, as well as the Flow Cytometry Crossmatch (FCXM) for 46 sera. We compared our results with those of SAB using 3 cutoffs, the first being the manufacturer's criteria where sensitivity and specificity were at 62.5% and 91.3% respectively for HLA class 1, and 88.5% and 50.0% respectively for HLA class 2. When using the third cutoff criteria (≥2 Adjusted values + MFI [Mean fluorescence intensity] >500 + Neg MFI < 500), the sensitivity increased to 69.0% for HLA class 1 and decreased to 84.0% for HLA class 2, while the specificity increased for HLA class 1 and 2. When comparing with FCXM, the 3 assays agreed in 55.8% of results for class 1 and 2 alike. However, major discrepancies were found for two groups in HLA class 1 and one in HLA class 2. The LumXm when used with other techniques to overcome its' weak points, can provide an interesting insight into the patient's HLA-DSA profile.

肾移植中的Luminex交叉配型。
Luminex交叉配型试验(LumXm)采用Luminex珠头技术,包括从供体淋巴细胞中提取人类白细胞抗原(HLA)分子,并将其结合到与受体血清接触的荧光珠上。HLA供体特异性抗体(DSA)检测使用荧光偶联物。我们研究的目的是确定在肾移植算法中使用LumXm的益处。我们使用LumXm检测了78例受体血清,并将结果与所有血清的Luminex单抗原珠测定(SAB)和46份血清的流式细胞术交叉匹配(FCXM)进行了比较。我们使用3个截止点将我们的结果与SAB的结果进行比较,第一个是制造商的标准,HLA 1型的敏感性和特异性分别为62.5%和91.3%,HLA 2型的敏感性和特异性分别为88.5%和50.0%。当使用第三个截止标准时(≥2调整值+ MFI[平均荧光强度]>500 +阴性MFI
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.70
自引率
5.40%
发文量
109
审稿时长
1 months
期刊介绍: This peer-reviewed international journal publishes original articles and reviews on all aspects of basic, translational and clinical immunology. The journal aims to provide high quality service to authors, and high quality articles for readers. The journal accepts for publication material from investigators all over the world, which makes a significant contribution to basic, translational and clinical immunology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信