Reexamining Compliance with Gastric Emptying Scintigraphy Guidelines: An Updated Analysis of the Intersocietal Accreditation Commission Database.

IF 1 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Dawood Tafti, Mary Beth Farrell, M Cory Dearborn, Kevin P Banks
{"title":"Reexamining Compliance with Gastric Emptying Scintigraphy Guidelines: An Updated Analysis of the Intersocietal Accreditation Commission Database.","authors":"Dawood Tafti, Mary Beth Farrell, M Cory Dearborn, Kevin P Banks","doi":"10.2967/jnmt.123.265496","DOIUrl":null,"url":null,"abstract":"<p><p>Many variables can influence the results of gastric emptying scintigraphy (GES). A lack of standardization causes variability, limits comparisons, and decreases the credibility of the study. To increase standardization, in 2009 the Society of Nuclear Medicine and Molecular Imaging (SNMMI) published a guideline for a standardized, validated GES protocol for adults based on a 2008 consensus document. Laboratories must closely follow the consensus guideline to provide valid and standardized results as an incentive to achieve consistency in patient care. As part of the accreditation process, the Intersocietal Accreditation Commission (IAC) evaluates compliance with such guidelines. The rate of compliance with the SNMMI guideline was assessed in 2016 and showed a substantial degree of noncompliance. The aim of this study was to reassess compliance with the standardized protocol across the same cohort of laboratories, looking for changes and trends. <b>Methods:</b> The IAC nuclear/PET database was used to extract GES protocols from all laboratories applying for accreditation from 2018 to 2021, 5 y after the initial assessment. The number of labs was 118 (vs. 127 in the initial assessment). Each protocol was again evaluated for compliance with the methods described in the SNMMI guideline. The same 14 variables were assessed in a binary fashion: patient preparation (4 variables-types of medications withheld, withholding of these medication for 48 h, blood glucose ≤ 200 mg/dL, blood glucose recorded), meal (5 variables-use of consensus meal, nothing by mouth for 4 h or more, meal consumed within 10 min, documentation of percentage of meal consumed, meal labeled with 18.5-37 MBq [0.5-1.0 mCi]), acquisition (2 variables-anterior and posterior projections obtained, imaging each hour out to 4 h), and processing (3 variables-use of the geometric mean, decay correction of data, and measurement of percentage retention). <b>Results:</b> Protocols from the 118 labs demonstrated that compliance is improving in some key areas but remains suboptimal in others. Overall, labs were compliant with an average of 8 of the 14 variables, with a low of 1-variable compliance at 1 site, and only 4 sites compliant with all 14 variables. Nineteen sites met an 80% threshold for compliance (11+ variables). The variable with the highest compliance was the patient's taking nothing by mouth for 4 h or more before the exam (97%). The variable with the lowest compliance was the recording of blood glucose values (3%). Notable areas of improvement include the use of the consensus meal, now 62% versus previously only 30% of labs. Greater compliance was also noted with measurement of retention percentages (instead of emptying percentages or half-times), with compliance by 65% of sites versus only 35% 5 y prior. <b>Conclusion:</b> Almost 13 y after the publication of the SNMMI GES guidelines, there is improving but still suboptimal protocol adherence among laboratories applying for IAC accreditation. Persistent variation in the performance of GES protocols may significantly affect patient management, as results may be unreliable. Using the standardized GES protocol permits interpretation of results in a consistent manner that allows interlaboratory comparisons and fosters acceptance of the test validity by referring clinicians.</p>","PeriodicalId":16548,"journal":{"name":"Journal of nuclear medicine technology","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2024-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10924152/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of nuclear medicine technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2967/jnmt.123.265496","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Many variables can influence the results of gastric emptying scintigraphy (GES). A lack of standardization causes variability, limits comparisons, and decreases the credibility of the study. To increase standardization, in 2009 the Society of Nuclear Medicine and Molecular Imaging (SNMMI) published a guideline for a standardized, validated GES protocol for adults based on a 2008 consensus document. Laboratories must closely follow the consensus guideline to provide valid and standardized results as an incentive to achieve consistency in patient care. As part of the accreditation process, the Intersocietal Accreditation Commission (IAC) evaluates compliance with such guidelines. The rate of compliance with the SNMMI guideline was assessed in 2016 and showed a substantial degree of noncompliance. The aim of this study was to reassess compliance with the standardized protocol across the same cohort of laboratories, looking for changes and trends. Methods: The IAC nuclear/PET database was used to extract GES protocols from all laboratories applying for accreditation from 2018 to 2021, 5 y after the initial assessment. The number of labs was 118 (vs. 127 in the initial assessment). Each protocol was again evaluated for compliance with the methods described in the SNMMI guideline. The same 14 variables were assessed in a binary fashion: patient preparation (4 variables-types of medications withheld, withholding of these medication for 48 h, blood glucose ≤ 200 mg/dL, blood glucose recorded), meal (5 variables-use of consensus meal, nothing by mouth for 4 h or more, meal consumed within 10 min, documentation of percentage of meal consumed, meal labeled with 18.5-37 MBq [0.5-1.0 mCi]), acquisition (2 variables-anterior and posterior projections obtained, imaging each hour out to 4 h), and processing (3 variables-use of the geometric mean, decay correction of data, and measurement of percentage retention). Results: Protocols from the 118 labs demonstrated that compliance is improving in some key areas but remains suboptimal in others. Overall, labs were compliant with an average of 8 of the 14 variables, with a low of 1-variable compliance at 1 site, and only 4 sites compliant with all 14 variables. Nineteen sites met an 80% threshold for compliance (11+ variables). The variable with the highest compliance was the patient's taking nothing by mouth for 4 h or more before the exam (97%). The variable with the lowest compliance was the recording of blood glucose values (3%). Notable areas of improvement include the use of the consensus meal, now 62% versus previously only 30% of labs. Greater compliance was also noted with measurement of retention percentages (instead of emptying percentages or half-times), with compliance by 65% of sites versus only 35% 5 y prior. Conclusion: Almost 13 y after the publication of the SNMMI GES guidelines, there is improving but still suboptimal protocol adherence among laboratories applying for IAC accreditation. Persistent variation in the performance of GES protocols may significantly affect patient management, as results may be unreliable. Using the standardized GES protocol permits interpretation of results in a consistent manner that allows interlaboratory comparisons and fosters acceptance of the test validity by referring clinicians.

重新审查胃排空闪烁成像指南的合规性:对协会间评审委员会数据库的最新分析。
胃排空闪烁扫描(GES)的结果会受到许多变量的影响。缺乏标准化会导致变异、限制比较并降低研究的可信度。为了提高标准化程度,2009 年,核医学与分子影像学会(SNMMI)在 2008 年共识文件的基础上发布了成人胃排空扫描标准化验证方案指南。实验室必须严格遵守该共识指南,以提供有效和标准化的结果,以此激励实现患者护理的一致性。作为认证程序的一部分,国际认证委员会(IAC)会对此类指南的合规性进行评估。2016 年对 SNMMI 指南的合规率进行了评估,结果显示存在很大程度的不合规。本研究的目的是重新评估同一批实验室对标准化方案的合规性,寻找变化和趋势。研究方法使用 IAC 核/PET 数据库提取 2018 年至 2021 年(首次评估后 5 年)所有申请评审的实验室的 GES 协议。实验室数量为 118 家(初次评估时为 127 家)。每项方案均按照 SNMMI 指南中描述的方法进行了再次评估。同样的 14 个变量以二进制方式进行评估:患者准备(4 个变量--暂停用药的类型、暂停用药 48 小时、血糖≤ 200 mg/dL、血糖记录)、用餐(5 个变量--使用共识餐、4 小时或更长时间内未口服任何药物、10 分钟内用餐、用餐百分比记录、用餐标注 18.5-37 MBq [0.5-1.0 mCi])、采集(2 个变量--获得前方和后方投影,每小时成像 4 小时)和处理(3 个变量--使用几何平均数、数据衰减校正和测量保留百分比)。结果:118 家实验室的方案表明,在某些关键领域的合规性正在提高,但在其他领域仍未达到最佳水平。总体而言,实验室平均符合 14 个变量中 8 个变量的要求,只有 1 个实验室符合 1 个变量的要求,只有 4 个实验室符合所有 14 个变量的要求。有 19 家实验室达到了 80% 的合规阈值(11 个以上变量)。依从性最高的变量是患者在检查前 4 小时或更长时间内未口服任何药物(97%)。依从性最低的变量是记录血糖值(3%)。值得注意的改进领域包括共识餐的使用,目前使用率为 62%,而以前仅为 30%。测量保留百分比(而不是排空百分比或半衰期)的依从性也有所提高,65% 的实验室都能做到,而 5 年前只有 35%。结论:在 SNMMI GES 指南发布近 13 年后,申请 IAC 认证的实验室对指南的遵守情况有所改善,但仍未达到最佳水平。GES 方案执行情况的持续差异可能会严重影响患者管理,因为结果可能并不可靠。使用标准化的 GES 方案可以以一致的方式解释结果,从而进行实验室间比较,并促进转诊临床医生对检验有效性的认可。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of nuclear medicine technology
Journal of nuclear medicine technology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.90
自引率
15.40%
发文量
57
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信