Hyojin Kim, Won Suk Yang, Dongheui An, Sang-Guk Lee, Je-Hyun Baek
{"title":"Fast and straightforward simultaneous quantification of multiple apolipoproteins in human serum on a high-throughput LC-MS/MS platform.","authors":"Hyojin Kim, Won Suk Yang, Dongheui An, Sang-Guk Lee, Je-Hyun Baek","doi":"10.1002/prca.202200056","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Apolipoprotein monitoring is useful for diagnosing cardiovascular diseases, as they are risk factors of arteriosclerosis and other neutral fat-related diseases. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is advantageous for simultaneous apolipoprotein quantification, differentiation, and standardization including their isoforms. However, fast and straightforward sample preparation that retains quantification accuracy remains challenging in clinical MS.</p><p><strong>Experimental design: </strong>We developed a simultaneous assay for serum apolipoprotein A-I (ApoA-I), apolipoprotein B100 family, and apolipoprotein C-III (ApoC-III) using a high-throughput LC-MS/MS platform coupled with a BRAVO system. The assay was simplified by using sodium deoxycholate and trypsin/lys-C without reduction and alkylation steps.</p><p><strong>Results: </strong>Simple sample preparation reduced turnaround time by 1.5 h and neat goat serum was chosen as an optimal calibration matrix for accurate protein quantification. Assay precision, linearity, correlation, accuracy, limit of detection (LOD), limit of quantitation (LOQ), and carryover were validated according to CLSI guidelines over 41 days using more than 100 human serum samples. Good correlation compared with turbidimetric immunoassay (TIA) was observed by Deming regression for all analytes.</p><p><strong>Conclusions and clinical relevance: </strong>A high-throughput LC-MS/MS and BRAVO assay for simultaneous apolipoprotein analysis was validated using a simple preparation method with a human serum calibrator in goat serum matrix. The assay is readily expandable to include other target serum proteins and/or their isoforms.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1002/prca.202200056","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Apolipoprotein monitoring is useful for diagnosing cardiovascular diseases, as they are risk factors of arteriosclerosis and other neutral fat-related diseases. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is advantageous for simultaneous apolipoprotein quantification, differentiation, and standardization including their isoforms. However, fast and straightforward sample preparation that retains quantification accuracy remains challenging in clinical MS.
Experimental design: We developed a simultaneous assay for serum apolipoprotein A-I (ApoA-I), apolipoprotein B100 family, and apolipoprotein C-III (ApoC-III) using a high-throughput LC-MS/MS platform coupled with a BRAVO system. The assay was simplified by using sodium deoxycholate and trypsin/lys-C without reduction and alkylation steps.
Results: Simple sample preparation reduced turnaround time by 1.5 h and neat goat serum was chosen as an optimal calibration matrix for accurate protein quantification. Assay precision, linearity, correlation, accuracy, limit of detection (LOD), limit of quantitation (LOQ), and carryover were validated according to CLSI guidelines over 41 days using more than 100 human serum samples. Good correlation compared with turbidimetric immunoassay (TIA) was observed by Deming regression for all analytes.
Conclusions and clinical relevance: A high-throughput LC-MS/MS and BRAVO assay for simultaneous apolipoprotein analysis was validated using a simple preparation method with a human serum calibrator in goat serum matrix. The assay is readily expandable to include other target serum proteins and/or their isoforms.