Salvatore Gitto, Domenico Albano, Francesca Serpi, Pierino Spadafora, Roberta Colombo, Carmelo Messina, Alberto Aliprandi, Luca Maria Sconfienza
{"title":"Diagnostic performance of high-resolution ultrasound in the evaluation of intrinsic and extrinsic wrist ligaments after trauma.","authors":"Salvatore Gitto, Domenico Albano, Francesca Serpi, Pierino Spadafora, Roberta Colombo, Carmelo Messina, Alberto Aliprandi, Luca Maria Sconfienza","doi":"10.1055/a-2066-9230","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the role of ultrasound (US) in the evaluation of intrinsic and extrinsic ligaments of the wrist with magnetic resonance arthrography (MRA) as the reference standard.</p><p><strong>Materials and methods: </strong>This prospective study included patients referred for MRA after wrist trauma. US examination was performed just before MRA. On the dorsal and palmar sides of the wrist, the intrinsic interosseus and midcarpal, extrinsic, and collateral ligaments were evaluated. MRA was performed on a 1.5-T unit. In the first 20 patients included, ligament thickness was independently assessed using US and MRA and thickness reproducibility was calculated. Ligament integrity was evaluated in all patients.</p><p><strong>Results: </strong>38 patients (22 men, 16 women; mean age: 38 years) were included. Ligament thickness reproducibility ranged between 44% for the palmar ulnocapitate ligament and 71% for the palmar scaphotriquetral ligament. US had a sensitivity, specificity, positive and negative predictive values, and accuracy of 100% in the identification of tears of the palmar (n=8) and dorsal (n=3) bands of the scapholunate ligament and the ulnar collateral ligament (n=3). It had a sensitivity of 100%, specificity of 97%, positive predictive value of 50%, negative predictive value of 100%, and accuracy of 97% in the identification of tears of the palmar ulnolunate ligament (n=1).</p><p><strong>Conclusion: </strong>Compared to MRA, US showed good reproducibility in the assessment of wrist ligament thickness and similar accuracy with respect to identifying tears of the scapholunate, palmar ulnolunate, and ulnar collateral ligaments.</p>","PeriodicalId":49400,"journal":{"name":"Ultraschall in Der Medizin","volume":" ","pages":"54-60"},"PeriodicalIF":3.1000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultraschall in Der Medizin","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2066-9230","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/3/31 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To investigate the role of ultrasound (US) in the evaluation of intrinsic and extrinsic ligaments of the wrist with magnetic resonance arthrography (MRA) as the reference standard.
Materials and methods: This prospective study included patients referred for MRA after wrist trauma. US examination was performed just before MRA. On the dorsal and palmar sides of the wrist, the intrinsic interosseus and midcarpal, extrinsic, and collateral ligaments were evaluated. MRA was performed on a 1.5-T unit. In the first 20 patients included, ligament thickness was independently assessed using US and MRA and thickness reproducibility was calculated. Ligament integrity was evaluated in all patients.
Results: 38 patients (22 men, 16 women; mean age: 38 years) were included. Ligament thickness reproducibility ranged between 44% for the palmar ulnocapitate ligament and 71% for the palmar scaphotriquetral ligament. US had a sensitivity, specificity, positive and negative predictive values, and accuracy of 100% in the identification of tears of the palmar (n=8) and dorsal (n=3) bands of the scapholunate ligament and the ulnar collateral ligament (n=3). It had a sensitivity of 100%, specificity of 97%, positive predictive value of 50%, negative predictive value of 100%, and accuracy of 97% in the identification of tears of the palmar ulnolunate ligament (n=1).
Conclusion: Compared to MRA, US showed good reproducibility in the assessment of wrist ligament thickness and similar accuracy with respect to identifying tears of the scapholunate, palmar ulnolunate, and ulnar collateral ligaments.
期刊介绍:
Ultraschall in der Medizin / European Journal of Ultrasound publishes scientific papers and contributions from a variety of disciplines on the diagnostic and therapeutic applications of ultrasound with an emphasis on clinical application. Technical papers with a physiological theme as well as the interaction between ultrasound and biological systems might also occasionally be considered for peer review and publication, provided that the translational relevance is high and the link with clinical applications is tight. The editors and the publishers reserve the right to publish selected articles online only. Authors are welcome to submit supplementary video material. Letters and comments are also accepted, promoting a vivid exchange of opinions and scientific discussions.