Comparative Evaluation of Apically Extruded Debris During Root Canal Preparation Using Three Different File Systems Applied Under 2.5% Sodium Hypochlorite or 2% CHX Irrigation.

IF 1.1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
P Zarean, M Özcan, M Molaie, A Mortaheb, N Al-Haj Husain, H Molaeinasab, M Zare Jahromi, P Zarean
{"title":"Comparative Evaluation of Apically Extruded Debris During Root Canal Preparation Using Three Different File Systems Applied Under 2.5% Sodium Hypochlorite or 2% CHX Irrigation.","authors":"P Zarean, M Özcan, M Molaie, A Mortaheb, N Al-Haj Husain, H Molaeinasab, M Zare Jahromi, P Zarean","doi":"10.1922/EJPRD_2499Zareana07","DOIUrl":null,"url":null,"abstract":"<p><p>The chemomechanical cleaning of the root canal system is performed using manual and rotary files. This study aimed to compare the effect of ProTaper, Reciproc and HyFlex rotary files considering 2.5% sodium hypochlorite and 2% chlorhexidine (CHX) as irrigating solutions on apical extrusion of intracanal debris. Single-canal mandibular premolars (N=165) were evaluated. The teeth were divided into 6 experimental groups (N=25) for root canal instrumentation using 3 file systems, (Reciproc, HyFlex and ProTaper) and two irrigation solutions, namely 2.5% sodium hypochlorite or 2% CHX. Fifteen teeth were also assigned into three control groups (n=5) with saline as irrigation solution. Eppendorf tubes were weighed and the teeth were placed inside. The canals were instrumented and the tubes weighed to determine the dry weight of extruded debris. Data were analyzed using one-way ANOVA and Bonferroni test (α=0.05). The mean amount of extruded debris using the sodium hypochlorite solution was significantly higher than other irrigating solutions (p⟨0.001). The mean amount of extruded debris using the Reciproc file system was significantly higher compared to ProTaper and HyFlex (p⟨0.001). The use of the sodium hypochlorite solution, single-file systems and reciprocal movement are associated with higher debris extrusion and might be associated with higher risk of postoperative pain.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":" ","pages":"391-397"},"PeriodicalIF":1.1000,"publicationDate":"2023-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Prosthodontics and Restorative Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1922/EJPRD_2499Zareana07","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

The chemomechanical cleaning of the root canal system is performed using manual and rotary files. This study aimed to compare the effect of ProTaper, Reciproc and HyFlex rotary files considering 2.5% sodium hypochlorite and 2% chlorhexidine (CHX) as irrigating solutions on apical extrusion of intracanal debris. Single-canal mandibular premolars (N=165) were evaluated. The teeth were divided into 6 experimental groups (N=25) for root canal instrumentation using 3 file systems, (Reciproc, HyFlex and ProTaper) and two irrigation solutions, namely 2.5% sodium hypochlorite or 2% CHX. Fifteen teeth were also assigned into three control groups (n=5) with saline as irrigation solution. Eppendorf tubes were weighed and the teeth were placed inside. The canals were instrumented and the tubes weighed to determine the dry weight of extruded debris. Data were analyzed using one-way ANOVA and Bonferroni test (α=0.05). The mean amount of extruded debris using the sodium hypochlorite solution was significantly higher than other irrigating solutions (p⟨0.001). The mean amount of extruded debris using the Reciproc file system was significantly higher compared to ProTaper and HyFlex (p⟨0.001). The use of the sodium hypochlorite solution, single-file systems and reciprocal movement are associated with higher debris extrusion and might be associated with higher risk of postoperative pain.

在2.5%次氯酸钠或2% CHX灌溉条件下,三种不同文件系统对根管预备过程中根尖挤压碎片的比较评价。
化学机械清洁的根管系统是使用手动和旋转锉。本研究旨在比较2.5%次氯酸钠和2%氯己定(CHX)作为冲洗溶液的ProTaper、Reciproc和HyFlex旋转锉对管内碎片根尖挤压的影响。评估单管下颌前磨牙(N=165)。采用3种锉制(Reciproc、HyFlex和ProTaper)和2种灌洗液(2.5%次氯酸钠或2% CHX)进行根管预备,分为6组(N=25)。15颗牙分为3个对照组(n=5),以生理盐水为冲洗液。对埃彭多夫管进行称重,并将牙齿放入其中。对管道进行仪器测量,对管道称重以确定挤压碎片的干重。数据分析采用单因素方差分析和Bonferroni检验(α=0.05)。次氯酸钠溶液挤出碎片的平均量显著高于其他冲洗溶液(p⟨0.001)。与ProTaper和HyFlex相比,Reciproc文件系统的平均挤出碎片量明显更高(p⟨0.001)。使用次氯酸钠溶液、单锉系统和相互运动与较高的碎片挤压有关,并可能与较高的术后疼痛风险有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.30
自引率
7.70%
发文量
0
期刊介绍: The European Journal of Prosthodontics and Restorative Dentistry is published quarterly and includes clinical and research articles in subjects such as prosthodontics, operative dentistry, implantology, endodontics, periodontics and dental materials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信