Diagnostic Value of Transbronchial Lung Cryobiopsy Using an Ultrathin Cryoprobe and Guide Sheath for Peripheral Pulmonary Lesions.

IF 3.3 Q2 RESPIRATORY SYSTEM
Chaeuk Chung, Yoonjoo Kim, Jeong Eun Lee, Da Hyun Kang, Dongil Park
{"title":"Diagnostic Value of Transbronchial Lung Cryobiopsy Using an Ultrathin Cryoprobe and Guide Sheath for Peripheral Pulmonary Lesions.","authors":"Chaeuk Chung, Yoonjoo Kim, Jeong Eun Lee, Da Hyun Kang, Dongil Park","doi":"10.1097/LBR.0000000000000917","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The addition of cryobiopsy to conventional biopsy methods improves the diagnostic yield of peripheral pulmonary lesions. Moreover, cryobiopsy with a guide sheath (GS) provides additional diagnostic benefits. Semi-real-time biopsy can be repeatedly performed using conventional biopsy devices and a GS, and subsequent cryobiopsy can be easily performed at the same location. Recently, a disposable 1.1 mm-diameter ultrathin cryoprobe has been developed and can be used with a 1.95 mm GS in a 2.0 mm working channel. In this study, we evaluated the diagnostic performance of transbronchial lung cryobiopsy (TBLC) with the 1.1 mm cryoprobe and a GS in patients with peripheral pulmonary lesions.</p><p><strong>Methods: </strong>We retrospectively reviewed the medical records of patients who underwent endobronchial ultrasound transbronchial lung biopsy with a guide sheath and TBLC from July 23, 2021 to April 30, 2022 at Chungnam National University Hospital.</p><p><strong>Results: </strong>Of a consecutive series of 229 patients, 199 were included. The diagnostic yields of forceps biopsy and cryobiopsy were 65.3% (130/199) and 84.4% (168/199), respectively, and the total diagnostic yield was 91.5% (182/199) ( P <0.001 vs. forceps biopsy). Multivariate analysis showed that solid lesion morphology [adjusted odds ratio (OR) 3.659, P =0.002] was associated with a significantly greater diagnostic yield of cryobiopsy, whereas a lesion diameter >20 mm ( P =0.026; adjusted OR 3.816) and 'within' orientation ( P =0.004; adjusted OR 6.174) were associated with a significantly greater overall diagnostic yield.</p><p><strong>Conclusion: </strong>TBLC using an ultrathin cryoprobe and GS markedly improves the diagnostic yield.</p>","PeriodicalId":15268,"journal":{"name":"Journal of Bronchology & Interventional Pulmonology","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10763711/pdf/","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Bronchology & Interventional Pulmonology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/LBR.0000000000000917","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 1

Abstract

Background: The addition of cryobiopsy to conventional biopsy methods improves the diagnostic yield of peripheral pulmonary lesions. Moreover, cryobiopsy with a guide sheath (GS) provides additional diagnostic benefits. Semi-real-time biopsy can be repeatedly performed using conventional biopsy devices and a GS, and subsequent cryobiopsy can be easily performed at the same location. Recently, a disposable 1.1 mm-diameter ultrathin cryoprobe has been developed and can be used with a 1.95 mm GS in a 2.0 mm working channel. In this study, we evaluated the diagnostic performance of transbronchial lung cryobiopsy (TBLC) with the 1.1 mm cryoprobe and a GS in patients with peripheral pulmonary lesions.

Methods: We retrospectively reviewed the medical records of patients who underwent endobronchial ultrasound transbronchial lung biopsy with a guide sheath and TBLC from July 23, 2021 to April 30, 2022 at Chungnam National University Hospital.

Results: Of a consecutive series of 229 patients, 199 were included. The diagnostic yields of forceps biopsy and cryobiopsy were 65.3% (130/199) and 84.4% (168/199), respectively, and the total diagnostic yield was 91.5% (182/199) ( P <0.001 vs. forceps biopsy). Multivariate analysis showed that solid lesion morphology [adjusted odds ratio (OR) 3.659, P =0.002] was associated with a significantly greater diagnostic yield of cryobiopsy, whereas a lesion diameter >20 mm ( P =0.026; adjusted OR 3.816) and 'within' orientation ( P =0.004; adjusted OR 6.174) were associated with a significantly greater overall diagnostic yield.

Conclusion: TBLC using an ultrathin cryoprobe and GS markedly improves the diagnostic yield.

使用超薄冷冻探针和导引鞘进行经支气管肺冷冻活组织检查对周围肺部病变的诊断价值
背景:在传统活组织检查方法的基础上增加冷冻活组织检查可提高外周肺部病变的诊断率。此外,使用导鞘(GS)进行低温活检还能带来额外的诊断优势。使用传统活检设备和导引鞘可重复进行半实时活检,随后的冷冻活检可在同一位置轻松进行。最近开发出了一种直径为 1.1 毫米的一次性超薄冷冻探针,可在 2.0 毫米的工作通道中与 1.95 毫米的 GS 配合使用。在这项研究中,我们评估了使用 1.1 毫米冷冻探针和 GS 对肺部周围病变患者进行经支气管肺冷冻活检(TBLC)的诊断效果:我们回顾性地查看了2021年7月23日至2022年4月30日在忠南大学医院接受支气管内超声经支气管肺活检术(带导鞘)和TBLC的患者的病历:结果:在229例连续系列患者中,199例被纳入。镊子活检和冷冻活检的诊断率分别为 65.3%(130/199)和 84.4%(168/199),总诊断率为 91.5%(182/199):结论:使用超薄冷冻探针和 GS 的 TBLC 能显著提高诊断率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.40
自引率
6.10%
发文量
121
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信