{"title":"The effect of the electromagnetic field on metabolic-active bacterial biofilm experimentallyinduced on titanium dental implants.","authors":"Grazia Brunetti, Elisa Valentini, Francesca Berlutti, Paolo Calvani, Flavia Raponi, Guido Antonelli, Umberto Romeo, Giammarco Raponi","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Microbial biofilm is of paramount importance in the development of mucositis or peri-implantitis in patients with dental implants. This study was designed to investigate whether an electromagnetic field at high frequency waves directly applied on 33 titanium implants could remove experimentally-induced Enterococcus faecalis bacterial biofilm. A specially designed device (X-IMPLANT) was used to generate the electromagnetic field, with output power of 8 W, supply frequency (action/pause) 3/2s, and an output frequency of 625±5% kHz in plastic devices containing the biofilm-covered implants immersed in sterile saline. The bacterial biofilm on both treated and untreated control implants was quantitatively measured by phenol red-based Bio-Timer-Assay reagent. The kinetic analysis of the curves showed that the electrical treatment generated by the X-IMPLANT device completely removed the bacterial biofilm after 30 minutes of treatment (p<0.01). Elimination of the biofilm was also confirmed by chromatic observation in the macro-method. Our data seem to indicate that the procedure could be considered for clinical application in peri-implantitis to counteract bacterial biofilm on dental implants.</p>","PeriodicalId":54723,"journal":{"name":"New Microbiologica","volume":"46 2","pages":"202-206"},"PeriodicalIF":1.5000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"New Microbiologica","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Microbial biofilm is of paramount importance in the development of mucositis or peri-implantitis in patients with dental implants. This study was designed to investigate whether an electromagnetic field at high frequency waves directly applied on 33 titanium implants could remove experimentally-induced Enterococcus faecalis bacterial biofilm. A specially designed device (X-IMPLANT) was used to generate the electromagnetic field, with output power of 8 W, supply frequency (action/pause) 3/2s, and an output frequency of 625±5% kHz in plastic devices containing the biofilm-covered implants immersed in sterile saline. The bacterial biofilm on both treated and untreated control implants was quantitatively measured by phenol red-based Bio-Timer-Assay reagent. The kinetic analysis of the curves showed that the electrical treatment generated by the X-IMPLANT device completely removed the bacterial biofilm after 30 minutes of treatment (p<0.01). Elimination of the biofilm was also confirmed by chromatic observation in the macro-method. Our data seem to indicate that the procedure could be considered for clinical application in peri-implantitis to counteract bacterial biofilm on dental implants.
期刊介绍:
The publication, diffusion and furtherance of research and study on all aspects of basic and clinical Microbiology and related fields are the chief aims of the journal.