Minimum Sampling Frequency for Accurate and Reliable Tibial Acceleration Measurements During Rearfoot Strike Running in the Field.

IF 1.1 4区 医学 Q4 ENGINEERING, BIOMEDICAL
Kevin G Aubol, Clare E Milner
{"title":"Minimum Sampling Frequency for Accurate and Reliable Tibial Acceleration Measurements During Rearfoot Strike Running in the Field.","authors":"Kevin G Aubol,&nbsp;Clare E Milner","doi":"10.1123/jab.2022-0069","DOIUrl":null,"url":null,"abstract":"<p><p>Field-based tibial acceleration measurements are increasingly common but sampling frequencies vary between accelerometers. The purpose of this study was to determine the minimum sampling frequency needed for reliable and accurate measurement of peak axial and resultant tibial acceleration during running in the field. Tibial acceleration was measured at 7161 Hz in 19 healthy runners on concrete and grass. Acceleration data were down sampled to approximate previously used sampling frequencies. Peak axial and resultant tibial acceleration were calculated for each sampling frequency. The within-session reliability and accuracy of peak axial and resultant tibial accelerations were evaluated using intraclass correlation coefficients, mean differences, and 95% limits of agreements. Intraclass correlation coefficients greater than .9 indicated excellent within-session reliability for both peak axial and resultant tibial acceleration measured while running on concrete and grass. Peak axial and resultant tibial accelerations were 0.5 to 1.4 g lower and minimal detectable differences were up to 0.6 g higher at 102 Hz compared with higher sampling frequencies. We recommend a minimum sampling frequency of 199 Hz for accurate and reliable measurements of peak axial and resultant tibial acceleration in the field.</p>","PeriodicalId":54883,"journal":{"name":"Journal of Applied Biomechanics","volume":"39 3","pages":"193-198"},"PeriodicalIF":1.1000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Biomechanics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1123/jab.2022-0069","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 1

Abstract

Field-based tibial acceleration measurements are increasingly common but sampling frequencies vary between accelerometers. The purpose of this study was to determine the minimum sampling frequency needed for reliable and accurate measurement of peak axial and resultant tibial acceleration during running in the field. Tibial acceleration was measured at 7161 Hz in 19 healthy runners on concrete and grass. Acceleration data were down sampled to approximate previously used sampling frequencies. Peak axial and resultant tibial acceleration were calculated for each sampling frequency. The within-session reliability and accuracy of peak axial and resultant tibial accelerations were evaluated using intraclass correlation coefficients, mean differences, and 95% limits of agreements. Intraclass correlation coefficients greater than .9 indicated excellent within-session reliability for both peak axial and resultant tibial acceleration measured while running on concrete and grass. Peak axial and resultant tibial accelerations were 0.5 to 1.4 g lower and minimal detectable differences were up to 0.6 g higher at 102 Hz compared with higher sampling frequencies. We recommend a minimum sampling frequency of 199 Hz for accurate and reliable measurements of peak axial and resultant tibial acceleration in the field.

准确可靠的胫骨加速度测量的最小采样频率。
基于场的胫骨加速度测量越来越普遍,但加速度计之间的采样频率不同。本研究的目的是确定在野外跑步时可靠和准确测量峰值轴向和由此产生的胫骨加速度所需的最小采样频率。在混凝土和草地上,19名健康跑步者的胫骨加速度为7161 Hz。加速度数据向下采样,以近似先前使用的采样频率。计算每个采样频率的峰值轴向加速度和由此产生的胫骨加速度。使用类内相关系数、平均差异和95%的一致性限来评估峰值轴向加速度和由此产生的胫骨加速度的组内可靠性和准确性。类内相关系数大于0.9表明,在混凝土和草地上跑步时测量的峰值轴向加速度和最终胫骨加速度的组内可靠性都很好。与较高的采样频率相比,102 Hz时的峰值轴向加速度和由此产生的胫骨加速度降低了0.5至1.4 g,最小可检测差异高达0.6 g。我们建议最小采样频率为199hz,以准确可靠地测量峰值轴向和由此产生的胫骨加速度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Applied Biomechanics
Journal of Applied Biomechanics 医学-工程:生物医学
CiteScore
2.00
自引率
0.00%
发文量
47
审稿时长
6-12 weeks
期刊介绍: The mission of the Journal of Applied Biomechanics (JAB) is to disseminate the highest quality peer-reviewed studies that utilize biomechanical strategies to advance the study of human movement. Areas of interest include clinical biomechanics, gait and posture mechanics, musculoskeletal and neuromuscular biomechanics, sport mechanics, and biomechanical modeling. Studies of sport performance that explicitly generalize to broader activities, contribute substantially to fundamental understanding of human motion, or are in a sport that enjoys wide participation, are welcome. Also within the scope of JAB are studies using biomechanical strategies to investigate the structure, control, function, and state (health and disease) of animals.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信