Duplicate Left-Sided Vagus Nerve: Intraoperative Imaging, Management, and Placement.

IF 0.6 Q4 CLINICAL NEUROLOGY
Nicholas Zacharewski, Brendan D Killory
{"title":"Duplicate Left-Sided Vagus Nerve: Intraoperative Imaging, Management, and Placement.","authors":"Nicholas Zacharewski,&nbsp;Brendan D Killory","doi":"10.1055/s-0043-1768713","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction</b>  Duplicate cranial nerves are fundamentally rare anatomical variants. Few case reports have documented cranial nerve duplication. One previous case report has reported a vagus nerve with a smaller secondary accessory nerve component. We present the first reported case of duplicate vagus nerves identical in size and thickness with otolaryngological diagnostic confirmation. <b>Case Description</b>  A 25-year-old woman with seizures refractory to medical management decided to undergo placement of a vagus nerve stimulator. During carotid sheath microdissection, two parallel nerve tracts were identified. The two nerves were identical in size and width. Proximal dissection confirmed that the two nerves were independent of one another and neither was a branching segment. To confirm duplicate vagus nerves, otolaryngology was consulted intraoperatively and the duplicate nerves were verified. The vagus nerve stimulator was placed in typical fashion around the medial nerve. <b>Conclusion</b>  This is the first reported case of duplicate vagus nerves identical in size and with confirmation by otolaryngology. The authors would like to highlight the operative management of the vagus nerve stimulator placement as well as integrity of the diagnostic conclusions based on size, further dissection, and specialist consultation.</p>","PeriodicalId":44256,"journal":{"name":"Journal of Neurological Surgery Reports","volume":null,"pages":null},"PeriodicalIF":0.6000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/95/50/10-1055-s-0043-1768713.PMC10195161.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Neurological Surgery Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0043-1768713","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction  Duplicate cranial nerves are fundamentally rare anatomical variants. Few case reports have documented cranial nerve duplication. One previous case report has reported a vagus nerve with a smaller secondary accessory nerve component. We present the first reported case of duplicate vagus nerves identical in size and thickness with otolaryngological diagnostic confirmation. Case Description  A 25-year-old woman with seizures refractory to medical management decided to undergo placement of a vagus nerve stimulator. During carotid sheath microdissection, two parallel nerve tracts were identified. The two nerves were identical in size and width. Proximal dissection confirmed that the two nerves were independent of one another and neither was a branching segment. To confirm duplicate vagus nerves, otolaryngology was consulted intraoperatively and the duplicate nerves were verified. The vagus nerve stimulator was placed in typical fashion around the medial nerve. Conclusion  This is the first reported case of duplicate vagus nerves identical in size and with confirmation by otolaryngology. The authors would like to highlight the operative management of the vagus nerve stimulator placement as well as integrity of the diagnostic conclusions based on size, further dissection, and specialist consultation.

Abstract Image

重复左侧迷走神经:术中成像、处理和放置。
重复脑神经是一种极为罕见的解剖变异。很少有病例报告显示脑神经重复。一个先前的病例报告报告迷走神经与较小的次级副神经组成部分。我们提出了第一个报告的病例重复迷走神经相同的大小和厚度与耳鼻喉科诊断确认。病例描述一名25岁的女性癫痫发作难治性决定接受迷走神经刺激器的放置。在颈动脉鞘显微解剖中,发现了两条平行的神经束。这两条神经的大小和宽度相同。近端解剖证实两神经彼此独立,两者都不是分支节段。术中求诊耳鼻喉科,确认重复神经。迷走神经刺激器以典型的方式放置在内侧神经周围。结论这是首例大小相同的迷走神经重复病例,经耳鼻喉科证实。作者想强调迷走神经刺激器放置的手术处理,以及基于大小、进一步解剖和专家咨询的诊断结论的完整性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
31
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信