{"title":"In vitro modeling of crimped Dacron vascular grafts for aortic root replacement.","authors":"Rakan I Nazer, Abdulaziz Alhothali, Ali Albarrati","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To objectively quantify the effect of flattening the crimps in Dacron tube grafts on the radial compliance under pulsatile pressure. We aimed to minimize the dimensional changes in woven Dacron graft tubes by applying axial stretch to the graft. We hypothesize this might reduce the risk of coronary button misalignment in aortic root replacement.</p><p><strong>Methods: </strong>In an in vitro pulsatile model that delivered systemic circulatory pressures to Dacron tube grafts, we measured oscillatory movements in 26-30 mm Dacron vascular tube grafts before and after flattening the graft crimps. We also describe our surgical methods and clinical experiences in replacing the aortic root.</p><p><strong>Results: </strong>Flattening the crimps in Dacron tubes with axial stretching significantly reduced the mean maximal oscillation distance measured radially during each balloon pulse (3.2 ± 0.8 mm, 95% CI: 2.6, 3.7 mm vs. 1.5 ± 0.5 mm, 95% CI: 1.2, 1.7 mm; P < 0.001).</p><p><strong>Conclusion: </strong>The radial compliance of woven Dacron tubes was significantly reduced after flattening the crimps. Applying axial stretch to the Dacron grafts prior to determining the coronary button attachment site can help maintain dimensional stability in the graft, which may reduce the risk of coronary malperfusion in aortic root replacment.</p>","PeriodicalId":7427,"journal":{"name":"American journal of cardiovascular disease","volume":"13 2","pages":"59-67"},"PeriodicalIF":1.3000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10193250/pdf/ajcd0013-0059.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of cardiovascular disease","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To objectively quantify the effect of flattening the crimps in Dacron tube grafts on the radial compliance under pulsatile pressure. We aimed to minimize the dimensional changes in woven Dacron graft tubes by applying axial stretch to the graft. We hypothesize this might reduce the risk of coronary button misalignment in aortic root replacement.
Methods: In an in vitro pulsatile model that delivered systemic circulatory pressures to Dacron tube grafts, we measured oscillatory movements in 26-30 mm Dacron vascular tube grafts before and after flattening the graft crimps. We also describe our surgical methods and clinical experiences in replacing the aortic root.
Results: Flattening the crimps in Dacron tubes with axial stretching significantly reduced the mean maximal oscillation distance measured radially during each balloon pulse (3.2 ± 0.8 mm, 95% CI: 2.6, 3.7 mm vs. 1.5 ± 0.5 mm, 95% CI: 1.2, 1.7 mm; P < 0.001).
Conclusion: The radial compliance of woven Dacron tubes was significantly reduced after flattening the crimps. Applying axial stretch to the Dacron grafts prior to determining the coronary button attachment site can help maintain dimensional stability in the graft, which may reduce the risk of coronary malperfusion in aortic root replacment.
目的:客观量化压平涤纶管对搏动压力下桡骨顺应性的影响。我们的目标是通过向接枝施加轴向拉伸来最小化编织涤纶接枝管的尺寸变化。我们假设这可能会降低主动脉根置换术中冠状动脉钮扣错位的风险。方法:建立体外脉动模型,给涤纶管移植物施加体循环压力,测量26-30 mm涤纶管移植物卷曲压平前后的振荡运动。同时我们也介绍了主动脉根部置换的手术方法和临床经验。结果:轴向拉伸使涤纶管卷曲变平可显著减少每次球囊脉冲径向测量的平均最大振荡距离(3.2±0.8 mm, 95% CI: 2.6, 3.7 mm vs. 1.5±0.5 mm, 95% CI: 1.2, 1.7 mm;P < 0.001)。结论:压平卷曲后织物涤纶管的径向顺应性明显降低。在确定冠状动脉钮扣附着位置之前,对涤纶移植物进行轴向拉伸,有助于维持移植物的尺寸稳定性,从而降低主动脉根置换术中冠状动脉灌注不良的风险。