Clinical Significance of Serum IgG4 in the Diagnosis and Treatment Response of IgG4-Related Disease in Adults of Southwest China: A Retrospective Study.
Bin Wei, Ying Guo, Xiaoqi Ou, Liyan Lin, Zhenzhen Su, Lixin Li, XiaoJuan Wu, Bei Cai
{"title":"Clinical Significance of Serum IgG4 in the Diagnosis and Treatment Response of IgG4-Related Disease in Adults of Southwest China: A Retrospective Study.","authors":"Bin Wei, Ying Guo, Xiaoqi Ou, Liyan Lin, Zhenzhen Su, Lixin Li, XiaoJuan Wu, Bei Cai","doi":"10.3343/alm.2023.43.5.461","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>There is no standard cut-off value of serum IgG4 concentration and serum IgG4/total IgG ratio for the diagnosis of IgG4-related disease (IgG4-RD) or as a marker of treatment responses. We aimed to explore this issue through a retrospective cohort analysis of adults in southwest China.</p><p><strong>Methods: </strong>The diagnostic performance of serum IgG4 concentration and IgG4/IgG ratio for IgG4-RD was evaluated in a retrospective analysis of 177 adults newly diagnosed as having IgG4-RD and 877 adults without IgG4-RD. Dynamic analysis was performed to evaluate the significance of serum IgG4 concentration on IgG4-RD treatment responses.</p><p><strong>Results: </strong>The serum IgG4 concentration differed according to sex. The optimal cut-off values of serum IgG4 concentration and IgG4/IgG ratio for IgG4-RD diagnosis were 1.92 g/L and 0.12 in males and 1.83 g/L and 0.11 in females, respectively. For patients with serum IgG4 concentration >2.01 g/L, the cut-off values in the total population were >3.00 g/L and 0.19, respectively. The median serum IgG4 concentration decreased over time, and the decrease rate increased over time. The serum IgG4 concentration significantly decreased at >1 week post-treatment (<i>P</i>=0.004), and the median decrease rate was close to 50% at >4 weeks post-treatment.</p><p><strong>Conclusions: </strong>Serum IgG4 can be a good indicator for IgG4-RD diagnosis; however, different diagnostic cut-off values should be determined according to sex. The decreasing rate is more conducive than the serum IgG4 concentration to monitor treatment efficacy. The IgG4/IgG ratio did not improve the diagnostic efficacy for IgG4-RD.</p>","PeriodicalId":8421,"journal":{"name":"Annals of Laboratory Medicine","volume":"43 5","pages":"461-469"},"PeriodicalIF":4.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/c5/27/alm-43-5-461.PMC10151269.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Laboratory Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3343/alm.2023.43.5.461","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: There is no standard cut-off value of serum IgG4 concentration and serum IgG4/total IgG ratio for the diagnosis of IgG4-related disease (IgG4-RD) or as a marker of treatment responses. We aimed to explore this issue through a retrospective cohort analysis of adults in southwest China.
Methods: The diagnostic performance of serum IgG4 concentration and IgG4/IgG ratio for IgG4-RD was evaluated in a retrospective analysis of 177 adults newly diagnosed as having IgG4-RD and 877 adults without IgG4-RD. Dynamic analysis was performed to evaluate the significance of serum IgG4 concentration on IgG4-RD treatment responses.
Results: The serum IgG4 concentration differed according to sex. The optimal cut-off values of serum IgG4 concentration and IgG4/IgG ratio for IgG4-RD diagnosis were 1.92 g/L and 0.12 in males and 1.83 g/L and 0.11 in females, respectively. For patients with serum IgG4 concentration >2.01 g/L, the cut-off values in the total population were >3.00 g/L and 0.19, respectively. The median serum IgG4 concentration decreased over time, and the decrease rate increased over time. The serum IgG4 concentration significantly decreased at >1 week post-treatment (P=0.004), and the median decrease rate was close to 50% at >4 weeks post-treatment.
Conclusions: Serum IgG4 can be a good indicator for IgG4-RD diagnosis; however, different diagnostic cut-off values should be determined according to sex. The decreasing rate is more conducive than the serum IgG4 concentration to monitor treatment efficacy. The IgG4/IgG ratio did not improve the diagnostic efficacy for IgG4-RD.
期刊介绍:
Annals of Laboratory Medicine is the official journal of Korean Society for Laboratory Medicine. The journal title has been recently changed from the Korean Journal of Laboratory Medicine (ISSN, 1598-6535) from the January issue of 2012. The JCR 2017 Impact factor of Ann Lab Med was 1.916.