Predicting late aortic complications after acute type A dissection surgery with volumetric measurements in a Singapore cohort.

IF 1.9 4区 医学 Q2 MEDICINE, GENERAL & INTERNAL
Singapore medical journal Pub Date : 2025-09-01 Epub Date: 2023-04-28 DOI:10.4103/singaporemedj.SMJ-2021-222
Jasmine Ge, Vinay Bahadur Panday, Siew-Pang Chan, Bernard Wee, Julian Chi Leung Wong, Leok Kheng Kristine Teoh, Moe Thu San, Carlos A Mestres, Theodoros Kofidis, Vitaly A Sorokin
{"title":"Predicting late aortic complications after acute type A dissection surgery with volumetric measurements in a Singapore cohort.","authors":"Jasmine Ge, Vinay Bahadur Panday, Siew-Pang Chan, Bernard Wee, Julian Chi Leung Wong, Leok Kheng Kristine Teoh, Moe Thu San, Carlos A Mestres, Theodoros Kofidis, Vitaly A Sorokin","doi":"10.4103/singaporemedj.SMJ-2021-222","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>This study was conducted to evaluate the efficacy of postoperative computed tomography (CT) measurements of aortic lumen volumes in predicting aortic-related complications following acute type A aortic dissection (ATAAD) repair.</p><p><strong>Methods: </strong>We conducted a single-institution retrospective aortic volumetric analysis of patients after ascending aorta replacement performed during 2001-2015. The volumetric measurements of total lumen (total-L), true lumen (TL), false lumen (FL), as well as the TL:FL ratio from the first and second postoperative computer angiograms were obtained. A generalised structural equation model was created to analyse the predictive utility of TL:FL ratio.</p><p><strong>Results: </strong>One hundred and twenty-five patients underwent surgical intervention, of whom 97 patients were eventually discharged and analysed for postoperative complications. A total of 19 patients were included in the final analysis. Patients with late postoperative aortic complications had a significantly higher FL volume and total-L volume on the first (FL volume P = 0.041, total-L volume P = 0.05) and second (FL volume P = 0.01, total-L volume P = 0.007) postoperative scans. The odds of having aortic complications were raised by 1% with a 1 cm 3 increase in total-L volume and by 2% with a 1 cm 3 increase in FL volume. The TL:FL ratio was significantly lower in patients who developed complications.</p><p><strong>Conclusion: </strong>Postoperative CT volumetric measurements in patients who developed complications are characterised by a significant increase in the FL volume and total-L volume from the first postoperative scans. Patients with disproportionately expanded FL presenting with TL:FL ratios less than 1 were associated with aortic complications. Hence, the TL:FL ratio may be a reliable and useful parameter to monitor postoperative disease progression and to evaluate the risk of late complications in ATAAD patients.</p>","PeriodicalId":21752,"journal":{"name":"Singapore medical journal","volume":" ","pages":"469-475"},"PeriodicalIF":1.9000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Singapore medical journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/singaporemedj.SMJ-2021-222","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/4/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: This study was conducted to evaluate the efficacy of postoperative computed tomography (CT) measurements of aortic lumen volumes in predicting aortic-related complications following acute type A aortic dissection (ATAAD) repair.

Methods: We conducted a single-institution retrospective aortic volumetric analysis of patients after ascending aorta replacement performed during 2001-2015. The volumetric measurements of total lumen (total-L), true lumen (TL), false lumen (FL), as well as the TL:FL ratio from the first and second postoperative computer angiograms were obtained. A generalised structural equation model was created to analyse the predictive utility of TL:FL ratio.

Results: One hundred and twenty-five patients underwent surgical intervention, of whom 97 patients were eventually discharged and analysed for postoperative complications. A total of 19 patients were included in the final analysis. Patients with late postoperative aortic complications had a significantly higher FL volume and total-L volume on the first (FL volume P = 0.041, total-L volume P = 0.05) and second (FL volume P = 0.01, total-L volume P = 0.007) postoperative scans. The odds of having aortic complications were raised by 1% with a 1 cm 3 increase in total-L volume and by 2% with a 1 cm 3 increase in FL volume. The TL:FL ratio was significantly lower in patients who developed complications.

Conclusion: Postoperative CT volumetric measurements in patients who developed complications are characterised by a significant increase in the FL volume and total-L volume from the first postoperative scans. Patients with disproportionately expanded FL presenting with TL:FL ratios less than 1 were associated with aortic complications. Hence, the TL:FL ratio may be a reliable and useful parameter to monitor postoperative disease progression and to evaluate the risk of late complications in ATAAD patients.

在新加坡队列中,用体积测量预测急性A型夹层手术后晚期主动脉并发症。
本研究旨在评估术后CT测量主动脉腔容量对急性A型主动脉夹层(ATAAD)修复后主动脉相关并发症的预测作用。方法:我们对2001-2015年间行升主动脉置换术的患者进行了单机构回顾性主动脉容积分析。获得术后第一次和第二次计算机血管造影的总管腔(total- l)、真管腔(TL)、假管腔(FL)的容积测量以及TL:FL比值。建立了一个广义结构方程模型来分析TL:FL比的预测效用。结果:125例患者接受手术治疗,其中97例最终出院,并对术后并发症进行了分析。共有19例患者被纳入最终分析。术后晚期主动脉并发症患者术后第一次扫描(FL容积P = 0.041,总l容积P = 0.05)和第二次扫描(FL容积P = 0.01,总l容积P = 0.007) FL容积和总l容积均明显增高。当总l容积增加1 cm 3时,发生主动脉并发症的几率增加1%,当FL容积增加1 cm 3时,发生主动脉并发症的几率增加2%。在出现并发症的患者中,TL:FL比率显著降低。结论:术后CT体积测量出现并发症的患者的特点是术后第一次扫描时FL体积和总l体积显著增加。不成比例扩大的FL患者TL:FL比值小于1与主动脉并发症相关。因此,TL:FL比值可能是监测ATAAD患者术后疾病进展和评估晚期并发症风险的可靠和有用的参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Singapore medical journal
Singapore medical journal MEDICINE, GENERAL & INTERNAL-
CiteScore
3.40
自引率
3.70%
发文量
149
审稿时长
3-6 weeks
期刊介绍: The Singapore Medical Journal (SMJ) is the monthly publication of Singapore Medical Association (SMA). The Journal aims to advance medical practice and clinical research by publishing high-quality articles that add to the clinical knowledge of physicians in Singapore and worldwide. SMJ is a general medical journal that focuses on all aspects of human health. The Journal publishes commissioned reviews, commentaries and editorials, original research, a small number of outstanding case reports, continuing medical education articles (ECG Series, Clinics in Diagnostic Imaging, Pictorial Essays, Practice Integration & Life-long Learning [PILL] Series), and short communications in the form of letters to the editor.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信