Mustafa Ozan Gürsoy, Cemalettin Yılmaz, Emrah Bayam, Ahmet Güner, Sadık Volkan Emren, Semih Kalkan, Yusuf Üzüm, Nurşen Keleş, Ali Karagöz, Mehmet Özkan
{"title":"Monocyte to HDL ratio may predict thrombosis in patients with mechanical mitral and aortic valve prosthesis.","authors":"Mustafa Ozan Gürsoy, Cemalettin Yılmaz, Emrah Bayam, Ahmet Güner, Sadık Volkan Emren, Semih Kalkan, Yusuf Üzüm, Nurşen Keleş, Ali Karagöz, Mehmet Özkan","doi":"10.1007/s10047-023-01395-y","DOIUrl":null,"url":null,"abstract":"<p><p>Increased inflammatory biomarkers have been reported in prosthetic heart valve thrombosis (PHVT). Monocyte to HDL ratio (MHR) and albumin to CRP levels (CAR) are two biomarkers used widely for systemic inflammation but there is a lack of data on prosthetic heart valves. This study aimed to find out the potential predictive value of MHR and CAR for PHVT. Patients who had the diagnosis of mechanical mitral/aortic PHVT and normally functioning prosthesis were retrospectively analyzed. Laboratory data including complete blood count and biochemistry were recorded. Transesophageal echocardiography was performed to diagnose PHVT. The study included 118 patients with mechanical PHVT and 120 patients with normally functioning prosthesis. White blood count, monocyte levels, C-reactive protein, MHR and CAR were significantly higher whereas the lymphocyte, HDL and INR levels on admission were lower in patients with PHVT. Multivariate analysis showed that as well as inadequate anticoagulation, MHR, but not CAR, was found to be an independent predictor of thrombosis in patients with PHVT. Receiver operating characteristic curve analysis was performed to detect the best cut-off value of MHR in the prediction of thrombosis in patients with prosthetic valves. MHR level of > 12.8 measured on admission, yielded an AUC value of 0.791 [(CI 95% 0.733-0.848 p < 0.001) sensitivity 71%, specificity 70%]. Inadequate anticoagulation is the primary cause that leads to thrombosis in mechanical prosthetic valves. Increased MHR, but not CAR, was also shown to be an independent predictor of thrombosis in patients with mechanical mitral and aortic prosthetic valves.</p>","PeriodicalId":15177,"journal":{"name":"Journal of Artificial Organs","volume":" ","pages":"117-124"},"PeriodicalIF":1.1000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-023-01395-y","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/4/21 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Increased inflammatory biomarkers have been reported in prosthetic heart valve thrombosis (PHVT). Monocyte to HDL ratio (MHR) and albumin to CRP levels (CAR) are two biomarkers used widely for systemic inflammation but there is a lack of data on prosthetic heart valves. This study aimed to find out the potential predictive value of MHR and CAR for PHVT. Patients who had the diagnosis of mechanical mitral/aortic PHVT and normally functioning prosthesis were retrospectively analyzed. Laboratory data including complete blood count and biochemistry were recorded. Transesophageal echocardiography was performed to diagnose PHVT. The study included 118 patients with mechanical PHVT and 120 patients with normally functioning prosthesis. White blood count, monocyte levels, C-reactive protein, MHR and CAR were significantly higher whereas the lymphocyte, HDL and INR levels on admission were lower in patients with PHVT. Multivariate analysis showed that as well as inadequate anticoagulation, MHR, but not CAR, was found to be an independent predictor of thrombosis in patients with PHVT. Receiver operating characteristic curve analysis was performed to detect the best cut-off value of MHR in the prediction of thrombosis in patients with prosthetic valves. MHR level of > 12.8 measured on admission, yielded an AUC value of 0.791 [(CI 95% 0.733-0.848 p < 0.001) sensitivity 71%, specificity 70%]. Inadequate anticoagulation is the primary cause that leads to thrombosis in mechanical prosthetic valves. Increased MHR, but not CAR, was also shown to be an independent predictor of thrombosis in patients with mechanical mitral and aortic prosthetic valves.
期刊介绍:
The aim of the Journal of Artificial Organs is to introduce to colleagues worldwide a broad spectrum of important new achievements in the field of artificial organs, ranging from fundamental research to clinical applications. The scope of the Journal of Artificial Organs encompasses but is not restricted to blood purification, cardiovascular intervention, biomaterials, and artificial metabolic organs. Additionally, the journal will cover technical and industrial innovations. Membership in the Japanese Society for Artificial Organs is not a prerequisite for submission.