Temporary Arteriovenous Fistula Compression for Clinical Decision-Making in Patients on Hemodialysis With Significant Aortic Stenosis.

Q2 Medicine
Ga Yun Kim, Sang Hyun Lee, Seok Hyun Kim, Jeongsu Kim, Yong Hyun Park
{"title":"Temporary Arteriovenous Fistula Compression for Clinical Decision-Making in Patients on Hemodialysis With Significant Aortic Stenosis.","authors":"Ga Yun Kim, Sang Hyun Lee, Seok Hyun Kim, Jeongsu Kim, Yong Hyun Park","doi":"10.4250/jcvi.2022.0088","DOIUrl":null,"url":null,"abstract":"https://e-jcvi.org A 57-year-old woman complained of dyspnea of New York Heart Association (NYHA) class III–IV and was transferred for surgery for severe degenerative aortic stenosis (AS). She had past history of chronic kidney disease on hemodialysis and hypertension. Initial echocardiography revealed moderate to severe degenerative AS with severe resting pulmonary hypertension (PH) and preserved left ventricular ejection fraction. Right heart catheterization was performed to find the cause of PH. The results showed combined post-capillary and pre-capillary PH with elevated cardiac index (CI) to 4.28 L/min/m2 (Table 1). Considering these results, the patient underwent intensive hemodialysis to reduce intravascular volume. However, AS peak jet velocity (Vpeak) was still high of 4.7 m/s with severe resting PH after volume reduction (Figure 1A). While evaluating causes of elevated CI, we found arteriovenous fistula (AVF) with high access flow rate (Figure 2). To determine the effects of increased transvalvular flow on measured parameters, we temporarily compressed AVF with blood pressure cuff to reduce shunt flow during echocardiography. During compression, Vpeak of aortic valve decreased to 3.6 m/s (Movies 1 and 2). The patient had revision of AVF to reduce shunt flow. After revision, echocardiography revealed moderate AS (Vpeak: 3.4 m/s) with mild resting PH (Figure 1B) and dyspnea was improved to NYHA class II. Continuity equation valve area was the same before and after surgery with value of 1.1 cm2 (Figure 3). High-flow state can overestimate AS severity.1) Causes of high-flow state should be identified and severity should be re-assessed when normal flow is restored.2) Temporary compression of AVF may be used for this purpose.1) J Cardiovasc Imaging. 2023 Apr;31(2):118-120 https://doi.org/10.4250/jcvi.2022.0088 pISSN 2586-7210·eISSN 2586-7296","PeriodicalId":15229,"journal":{"name":"Journal of Cardiovascular Imaging","volume":"31 2","pages":"118-120"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/5f/4c/jcvi-31-118.PMC10133805.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4250/jcvi.2022.0088","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

https://e-jcvi.org A 57-year-old woman complained of dyspnea of New York Heart Association (NYHA) class III–IV and was transferred for surgery for severe degenerative aortic stenosis (AS). She had past history of chronic kidney disease on hemodialysis and hypertension. Initial echocardiography revealed moderate to severe degenerative AS with severe resting pulmonary hypertension (PH) and preserved left ventricular ejection fraction. Right heart catheterization was performed to find the cause of PH. The results showed combined post-capillary and pre-capillary PH with elevated cardiac index (CI) to 4.28 L/min/m2 (Table 1). Considering these results, the patient underwent intensive hemodialysis to reduce intravascular volume. However, AS peak jet velocity (Vpeak) was still high of 4.7 m/s with severe resting PH after volume reduction (Figure 1A). While evaluating causes of elevated CI, we found arteriovenous fistula (AVF) with high access flow rate (Figure 2). To determine the effects of increased transvalvular flow on measured parameters, we temporarily compressed AVF with blood pressure cuff to reduce shunt flow during echocardiography. During compression, Vpeak of aortic valve decreased to 3.6 m/s (Movies 1 and 2). The patient had revision of AVF to reduce shunt flow. After revision, echocardiography revealed moderate AS (Vpeak: 3.4 m/s) with mild resting PH (Figure 1B) and dyspnea was improved to NYHA class II. Continuity equation valve area was the same before and after surgery with value of 1.1 cm2 (Figure 3). High-flow state can overestimate AS severity.1) Causes of high-flow state should be identified and severity should be re-assessed when normal flow is restored.2) Temporary compression of AVF may be used for this purpose.1) J Cardiovasc Imaging. 2023 Apr;31(2):118-120 https://doi.org/10.4250/jcvi.2022.0088 pISSN 2586-7210·eISSN 2586-7296

Abstract Image

Abstract Image

Abstract Image

临时动静脉瘘压迫在血液透析伴明显主动脉狭窄患者临床决策中的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Cardiovascular Imaging
Journal of Cardiovascular Imaging Medicine-Cardiology and Cardiovascular Medicine
CiteScore
3.40
自引率
0.00%
发文量
42
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信