{"title":"Transradial access with Simmons guiding catheter for carotid artery stenting: Feasibility and procedural complications in a single-center experience.","authors":"P Muszynski, S Richard, S Finitsis, L Humbertjean, G Audibert, G Mione, O Harsan, A L Derelle, L Liao, F Zhu, J M Olivot, R Anxionnat, D Calvet, Benjamin Gory","doi":"10.1177/15910199231171845","DOIUrl":null,"url":null,"abstract":"<p><p>BackgroundThere is an increasing number of transradial approach (TRA) for carotid artery stenting (CAS), however, similar techniques and materials as for femoral access are used. We report the results of TRA lower profile technique for CAS using a 7 F Simmons guiding catheter, especially in terms of feasibility and procedural safety in a single center.Materials and MethodsWe retrospectively analyzed 68 consecutive patients with symptomatic extracranial carotid stenoses who underwent 75 CAS between January 2018 and December 2021. The success and crossover rate, procedural time, fluoroscopy, clinical outcomes, technical considerations, and procedural complications were analyzed.ResultsTRA CAS with Simmons guiding catheter was successful in 67/75 (89.3%) cases, with a 7 (9.3%) crossover rate. Fluoroscopy mean time was 15.8 minutes. Two forearm hematomas were described. No ischemic or surgical site complications were reported.ConclusionsIn our experience frontline TRA with a 7 F Simmons guiding catheter is feasible with high procedural success and a low rate of access site complications.</p>","PeriodicalId":14380,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"496-501"},"PeriodicalIF":2.1000,"publicationDate":"2025-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12280257/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199231171845","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/4/27 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

BackgroundThere is an increasing number of transradial approach (TRA) for carotid artery stenting (CAS), however, similar techniques and materials as for femoral access are used. We report the results of TRA lower profile technique for CAS using a 7 F Simmons guiding catheter, especially in terms of feasibility and procedural safety in a single center.Materials and MethodsWe retrospectively analyzed 68 consecutive patients with symptomatic extracranial carotid stenoses who underwent 75 CAS between January 2018 and December 2021. The success and crossover rate, procedural time, fluoroscopy, clinical outcomes, technical considerations, and procedural complications were analyzed.ResultsTRA CAS with Simmons guiding catheter was successful in 67/75 (89.3%) cases, with a 7 (9.3%) crossover rate. Fluoroscopy mean time was 15.8 minutes. Two forearm hematomas were described. No ischemic or surgical site complications were reported.ConclusionsIn our experience frontline TRA with a 7 F Simmons guiding catheter is feasible with high procedural success and a low rate of access site complications.

经桡动脉入路Simmons导管用于颈动脉支架置入:单中心经验的可行性和手术并发症。
背景颈动脉支架植入术(CAS)的经桡动脉入路(TRA)越来越多,然而,使用的技术和材料与股骨入路相似。我们报告了TRA低姿态技术在CAS中使用7f Simmons导尿管的结果,特别是在单中心的可行性和操作安全性方面。材料和方法我们回顾性分析了2018年1月至2021年12月期间连续68例有症状的颈动脉颅外狭窄患者,这些患者接受了75例CAS。分析手术成功率和交叉率、手术时间、透视检查、临床结果、技术注意事项和手术并发症。结果采用Simmons导尿管行CAS的成功率为67/75(89.3%),交叉率为7(9.3%)。平均透视时间15.8分钟。描述了2例前臂血肿。无缺血性或手术部位并发症报道。结论根据我们的经验,采用7f Simmons导尿管行一线TRA是可行的,手术成功率高,通路并发症发生率低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.80
自引率
11.80%
发文量
192
审稿时长
6-12 weeks
期刊介绍: Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信