{"title":"Long-term valve performance of St Jude Medical Epic porcine bioprosthesis in aortic position.","authors":"Kana Shibata, Shusaku Maeda, Noriyuki Kashiyama, Hiroki Nakatsuji, Masahiro Ryugo, Yasushi Tsutsumi, Osamu Monta","doi":"10.1007/s10047-023-01401-3","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to review long-term clinical outcomes and valve performance after Epic Supra valve implantation in aortic position. From 2011 to 2022, 44 patients (mean age 75 ± 8 years) underwent surgical aortic valve replacement (SAVR) with an Epic Supra valve at our hospital. Survival, incidence of late complications, and echocardiographic date were retrospectively analyzed. During a mean follow-up period of 6.2 ± 3.5 years, the overall survival rate was 91 ± 4% at 2 and 88 ± 5% at 5 years, while rates of freedom from major adverse cardiovascular and cerebrovascular events (MACCE) were 86 ± 5% and 83 ± 6%, respectively. There was one case of reoperation for prosthetic valve endocarditis at 6 years after the initial surgery. Echocardiographic examinations showed 5-year rates of freedom from severe structural valve deterioration (SVD) and moderate SVD of 100 and 92%, respectively. There was no significant increase in mean pressure gradient or decrease in left ventricular ejection fraction from 1 week after surgery to the late follow-up period. Long-term clinical results and durability of the Epic Supra valve in aortic position were satisfactory.</p>","PeriodicalId":15177,"journal":{"name":"Journal of Artificial Organs","volume":" ","pages":"131-137"},"PeriodicalIF":1.1000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-023-01401-3","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/4/26 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
The aim of this study was to review long-term clinical outcomes and valve performance after Epic Supra valve implantation in aortic position. From 2011 to 2022, 44 patients (mean age 75 ± 8 years) underwent surgical aortic valve replacement (SAVR) with an Epic Supra valve at our hospital. Survival, incidence of late complications, and echocardiographic date were retrospectively analyzed. During a mean follow-up period of 6.2 ± 3.5 years, the overall survival rate was 91 ± 4% at 2 and 88 ± 5% at 5 years, while rates of freedom from major adverse cardiovascular and cerebrovascular events (MACCE) were 86 ± 5% and 83 ± 6%, respectively. There was one case of reoperation for prosthetic valve endocarditis at 6 years after the initial surgery. Echocardiographic examinations showed 5-year rates of freedom from severe structural valve deterioration (SVD) and moderate SVD of 100 and 92%, respectively. There was no significant increase in mean pressure gradient or decrease in left ventricular ejection fraction from 1 week after surgery to the late follow-up period. Long-term clinical results and durability of the Epic Supra valve in aortic position were satisfactory.
期刊介绍:
The aim of the Journal of Artificial Organs is to introduce to colleagues worldwide a broad spectrum of important new achievements in the field of artificial organs, ranging from fundamental research to clinical applications. The scope of the Journal of Artificial Organs encompasses but is not restricted to blood purification, cardiovascular intervention, biomaterials, and artificial metabolic organs. Additionally, the journal will cover technical and industrial innovations. Membership in the Japanese Society for Artificial Organs is not a prerequisite for submission.