{"title":"Ultrafiltration-induced decrease in relative blood volume is larger in hemodialysis patients with low specific blood volume: Results from a dialysate bolus administration study","authors":"Michael Schmiedecker, Simon Krenn, Maximilian Waller, Christopher Paschen, Sebastian Mussnig, Janosch Niknam, Peter Wabel, Christopher C. Mayer, Manfred Hecking, Daniel Schneditz","doi":"10.1111/hdi.13066","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Introduction</h3>\n \n <p>Prescribing the ultrafiltration in hemodialysis patients remains challenging and might benefit from the information on absolute blood volume, estimated by intradialytic dialysate bolus administration. Here, we aimed at determining the relationship between absolute blood volume, normalized for body mass (specific blood volume, Vs), and ultrafiltration-induced decrease in relative blood volume (∆RBV) as well as clinical parameters including body mass index (BMI).</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>This retrospective analysis comprised 77 patients who had their dialysate bolus-based absolute blood volume extracted routinely with an automated method. Patient-specific characteristics and ∆RBV were analyzed as a function of Vs, dichotomizing the data above or below a previously proposed threshold of 65 ml/kg for Vs. Statistical methodology comprised descriptive analyses, two-group comparisons, and correlation analyses.</p>\n </section>\n \n <section>\n \n <h3> Findings</h3>\n \n <p>Median Vs was 68.6 ml/kg (54.9 ml/kg [Quartile 1], 83.4 ml/kg [Quartile 3]). Relative blood volume decreased by 6.3% (2.6%, 12.2%) over the entire hemodialysis session. Vs correlated inversely with BMI (r<sub>s</sub> = −0.688, <i>p</i> < 0.001). ∆RBV was 9.8% in the group of patients with Vs <65 ml/kg versus 6.0% in the group of patients with Vs ≥65 ml/kg (<i>p</i> = 0.024). The two groups did not differ significantly regarding their specific ultrafiltration volume, normalized for body mass, which amounted to 34.1 ml/kg and 36.0 ml/kg in both groups, respectively (<i>p</i> = 0.630). ∆RBV correlated inversely with Vs (r<sub>s</sub> = −0.299, <i>p</i> = 0.008).</p>\n </section>\n \n <section>\n \n <h3> Discussion</h3>\n \n <p>The present study suggests that patients with higher BMI and lower Vs experience larger blood volume changes, despite similar ultrafiltration requirements. These results underline the clinical plausibility and importance of dialysate bolus-based absolute blood volume determination in the assessment of target weight, especially in view of a previous study where intradialytic morbid events could be decreased when the target weight was adjusted, based on Vs.</p>\n </section>\n </div>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-01-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/hdi.13066","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/hdi.13066","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction
Prescribing the ultrafiltration in hemodialysis patients remains challenging and might benefit from the information on absolute blood volume, estimated by intradialytic dialysate bolus administration. Here, we aimed at determining the relationship between absolute blood volume, normalized for body mass (specific blood volume, Vs), and ultrafiltration-induced decrease in relative blood volume (∆RBV) as well as clinical parameters including body mass index (BMI).
Methods
This retrospective analysis comprised 77 patients who had their dialysate bolus-based absolute blood volume extracted routinely with an automated method. Patient-specific characteristics and ∆RBV were analyzed as a function of Vs, dichotomizing the data above or below a previously proposed threshold of 65 ml/kg for Vs. Statistical methodology comprised descriptive analyses, two-group comparisons, and correlation analyses.
Findings
Median Vs was 68.6 ml/kg (54.9 ml/kg [Quartile 1], 83.4 ml/kg [Quartile 3]). Relative blood volume decreased by 6.3% (2.6%, 12.2%) over the entire hemodialysis session. Vs correlated inversely with BMI (rs = −0.688, p < 0.001). ∆RBV was 9.8% in the group of patients with Vs <65 ml/kg versus 6.0% in the group of patients with Vs ≥65 ml/kg (p = 0.024). The two groups did not differ significantly regarding their specific ultrafiltration volume, normalized for body mass, which amounted to 34.1 ml/kg and 36.0 ml/kg in both groups, respectively (p = 0.630). ∆RBV correlated inversely with Vs (rs = −0.299, p = 0.008).
Discussion
The present study suggests that patients with higher BMI and lower Vs experience larger blood volume changes, despite similar ultrafiltration requirements. These results underline the clinical plausibility and importance of dialysate bolus-based absolute blood volume determination in the assessment of target weight, especially in view of a previous study where intradialytic morbid events could be decreased when the target weight was adjusted, based on Vs.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.